1.Effect of anesthesia management in enhanced recovery after surgery on stress level in thyroid surgery
Zhuochen LYU ; Chenjun XIONG ; Jiqi YAN ; Shiyu ZHANG ; Zichen HUA ; Xiayang YING ; Yan LUO
The Journal of Clinical Anesthesiology 2017;33(8):733-737
Objective To compare the effect of anesthesia management between enhanced recovery after surgery (ERAS) protocol and traditional protocol on stress level of thyroid surgery.Methods Sixty-two patients receiving thyroid surgery from May 2016 to August 2016, 13 males and 49 females, aged 18-65 years, of ASA physical status Ⅰ or Ⅱ, were randomly divided into group ERAS (n=29) and traditional group (group C, n=33).Each group had its own anesthesia management protocol.Operation method, operation duration, the level of pain during emergence and on the first postoperative day, the occurrence rate of complications and the satisfaction evaluation of pain and nausea and vomiting after the operation day were recorded.C-reactive protein (CRP), serum cortisol, interleukin-6 (IL-6), interleukin-8 (IL-8) and tumor necrosis factor (TNF-α) before and after the operation day were evaluated.Results The visual analogue scale (VAS) pain score in group ERAS was lower than that in group C during emergence [(0.42±0.83) points vs (0.95±1.16) points]and on the first postoperative day [(1.90±1.21) points vs (2.73±1.40) points] (P<0.05).Group ERAS was more satisfied with pain relief at first day after the surgery than that of group C (P<0.05).The level of CRP in group ERAS was lower than that in group C on the operative day and the first postoperative day (P<0.05).In group C, the level of CRP on the operative day and the first postoperative day were much higher than those before the surgery (P<0.05).The occurrence rate of complications between the two groups had no statistical difference.Conclusion The perioperative ERAS anesthesia management of thyroid surgery is safe and effective in pain management, patient satisfaction and accelerated recovery.
2.Optimization of labeling methods for a novel prostate cancer PET probe Al 18F-PSMA-137
Zhuochen ZHANG ; Xiaojiang DUAN ; Xuhe LIAO ; Hongwei SUN ; Yan FAN ; Xing YANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2023;43(4):206-210
Objective:To investigate the effects of different labeling conditions on the yield of Al 18F-labeled 1, 4, 7-triazacylononane-1, 4, 7-triaceticacid (NOTA)-prostate specific membrane antigen (PSMA)-137, and to determine the experimental condition for obtaining Al 18F-PSMA-137 probe in high yield. Methods:The effects of different pH values, buffer systems (acetic acid-sodium acetate buffer system and potassium hydrogen phthalate (KHP) buffer system), AlCl 3-ligand ratios, ligand amounts, ethanol volumes and reaction temperatures on the labeling rate were investigated in detail. Results:The pH value of the reaction solution had a significant effect on the labeling rate, and the optimal range was 4.0-4.5. When the pH value was higher than 4.5, the labeling rate decreased significantly. Both the acetic acid-sodium acetate buffer system and the KHP buffer system could be used to label NOTA-PSMA-137 with Al 18F, and the KHP buffer system obtained higher labeling rate. The ratio of AlCl 3-ligand affected the labeling rate, and the highest labeling rate could be obtained when the ratio of AlCl 3-ligand was 0.54-0.62. When the ratio of AlCl 3-ligand was fixed, increasing the amount of ligand could improve the labeling yield. Adding hydrophilic organic solvent ethanol to the reaction system could significantly increase yield, with the highest labeling rate being achieved at a volume of 100 μl ethanol. The most suitable reaction temperature was 100 ℃, and when the temperature raised to 110 ℃, the labeling rate decreased significantly. The most suitable labeling conditions for NOTA-PSMA-137 were as following: 25 μl KHP buffer (0.50 mol/L, pH=4.0), 7.0 μl AlCl 3 solution (20 mmol/L), 200 μl Na 18F solution (74-80 MBq) and 230 μg ligand NOTA-PSMA-137 were mixed in a vial, then stood for 5 min and 100 μl ethanol was added, and all reagents were heated at 100 ℃ for 10 min. The yield of Al 18F-PSMA-137 under above conditions were 85.7%-88.5%. Conclusion:Optimization of labeling condition can improve the yield of Al 18F-PSMA-137 and the stability of the labeling.