1.Optimization of labeling methods for a novel prostate cancer PET probe Al 18F-PSMA-137
Zhuochen ZHANG ; Xiaojiang DUAN ; Xuhe LIAO ; Hongwei SUN ; Yan FAN ; Xing YANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2023;43(4):206-210
Objective:To investigate the effects of different labeling conditions on the yield of Al 18F-labeled 1, 4, 7-triazacylononane-1, 4, 7-triaceticacid (NOTA)-prostate specific membrane antigen (PSMA)-137, and to determine the experimental condition for obtaining Al 18F-PSMA-137 probe in high yield. Methods:The effects of different pH values, buffer systems (acetic acid-sodium acetate buffer system and potassium hydrogen phthalate (KHP) buffer system), AlCl 3-ligand ratios, ligand amounts, ethanol volumes and reaction temperatures on the labeling rate were investigated in detail. Results:The pH value of the reaction solution had a significant effect on the labeling rate, and the optimal range was 4.0-4.5. When the pH value was higher than 4.5, the labeling rate decreased significantly. Both the acetic acid-sodium acetate buffer system and the KHP buffer system could be used to label NOTA-PSMA-137 with Al 18F, and the KHP buffer system obtained higher labeling rate. The ratio of AlCl 3-ligand affected the labeling rate, and the highest labeling rate could be obtained when the ratio of AlCl 3-ligand was 0.54-0.62. When the ratio of AlCl 3-ligand was fixed, increasing the amount of ligand could improve the labeling yield. Adding hydrophilic organic solvent ethanol to the reaction system could significantly increase yield, with the highest labeling rate being achieved at a volume of 100 μl ethanol. The most suitable reaction temperature was 100 ℃, and when the temperature raised to 110 ℃, the labeling rate decreased significantly. The most suitable labeling conditions for NOTA-PSMA-137 were as following: 25 μl KHP buffer (0.50 mol/L, pH=4.0), 7.0 μl AlCl 3 solution (20 mmol/L), 200 μl Na 18F solution (74-80 MBq) and 230 μg ligand NOTA-PSMA-137 were mixed in a vial, then stood for 5 min and 100 μl ethanol was added, and all reagents were heated at 100 ℃ for 10 min. The yield of Al 18F-PSMA-137 under above conditions were 85.7%-88.5%. Conclusion:Optimization of labeling condition can improve the yield of Al 18F-PSMA-137 and the stability of the labeling.
2.Research progress of anatomical segmentectomy in the treatment of early non-small cell lung cancer
Zhuochen SUN ; Yunchao HUANG ; Guangqiang ZHAO ; Xuancheng LI ; Shouzhuo LI ; Yuandong SUO ; Di MENG
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2022;29(10):1384-1389
Lung cancer, as one of the malignant tumors with the fastest increasing morbidity and mortality in the world, has a serious impact on people's health. With the continuous advancement of medical technology, more and more medical methods are applied to lung cancer screening, which has gradually increased the detection rate of early lung cancer. At present, the standard operation for the treatment of early non-small cell lung cancer (NSCLC) is still lobectomy and mediastinal lymph node dissection. There is a growing trend to use segmentectomy for the treatment of early stage lung cancer. Anatomical segmentectomy not only removes the lesions to the maximum extent, but also preserves the lung function to the greatest extent, and its advantages are also obvious. This article reviews the progress of anatomical segmentectomy in the treatment of early NSCLC.