1.The clinical significance of two fecal occult blood tests in diagnosis of gastrointestinal hemorrhage
Ping GAO ; Shaogang ZHANG ; Meiyan ZHANG ; Zhuobin TANG ; Limei ZHANG ; Biao LU ; Lihong CHEN
Chinese Journal of Digestion 2009;29(8):518-520
Objective To assess and compare chemical and immunochemical fecal occult blood tests (FOBTs) in diagnosis of gastrointestinal hemorrhage and their clinical significance. Methods The FOBT was carried out in 4474 in-patients, out-patients or subjects who had annual physical examination using both hemoccult Ⅱ (CFOBT) and colloidal gold chromagraphy (IFOBT) methods.Those who was positive for FOBTs would be re-tested for 2 times and followed by gastroscopy and colonoscopy as well as other examinations in order to find the reason and location of gastrointestinal hemorrhage. Results FOBT was positive in 390 (8.22%) patients, of which 163 (41.8%) were detected by CFOBT, 100(25.6%) by IFOBT, and 127(32.6%) by both CFOBT and IFOBT. The clinical, endoscopic and other examinations revealed that upper and lower gastrointestinal bleeding were found in 235 (60.3%) and 136 (34.9%) patients, respectively. The detective rates of upper and lower gastrointestinal bleeding were 90.2% and 67.6% by CFOBT respectively, and 42.5% and 93.4% by IFOBT, respectively. The obvious gastrointestinal bleeding could be detected by both CFOBT and IFOBT. The diseases related to gastrointestinal bleeding involved acute gastric mucosal lesion, peptic ulcer, gastric cancer and colonic polyp,colorectal cancer and piles, etc. Conclusions It is demonstrated that FOBT is still important in screening and diagnosis of gastrointestinal hemorrhage.The CFOBT is superior to IFOBT in detecting upper gastrointestinal bleeding, whereas the IFOBT is superior to CFOBT in detecting lower gastrointestinal bleeding.
2.Multiple transmission electron microscopic image stitching based on sift features.
Mu LI ; Yanmeng LU ; Shuaihu HAN ; Zhuobin WU ; Jiajing CHEN ; Zhexing LIU ; Lei CAO
Journal of Southern Medical University 2015;35(9):1251-1257
We proposed a new stitching method based on sift features to obtain an enlarged view of transmission electron microscopic (TEM) images with a high resolution. The sift features were extracted from the images, which were then combined with fitted polynomial correction field to correct the images, followed by image alignment based on the sift features. The image seams at the junction were finally removed by Poisson image editing to achieve seamless stitching, which was validated on 60 local glomerular TEM images with an image alignment error of 62.5 to 187.5 nm. Compared with 3 other stitching methods, the proposed method could effectively reduce image deformation and avoid artifacts to facilitate renal biopsy pathological diagnosis.
Algorithms
;
Artifacts
;
Humans
;
Image Processing, Computer-Assisted
;
methods
;
Kidney Glomerulus
;
ultrastructure
;
Microscopy, Electron, Transmission
;
methods
3.The mutation characteristics of drug-resistance of Mycobacterium tuberculosis in Qinzhou,Guangxi
Chongjian LI ; Jingui BAO ; Zhuobin CHEN ; Shijuan LI ; Haisong WU ; Ling LIANG
International Journal of Laboratory Medicine 2018;39(8):936-938
Objective To analyze the variation characteristics of rpoB,katG,inhA,rpsL and embB related genes of Mycobacterium tuberculosis(MTB)in Qinzhou,Guangxi.Methods PCR reverse point hybridization was used to detect 5 common resistance mutants of Mycobacterium tuberculosis in 237 MTB-DNA positive sputum samples.Results Among 237 cases of tuberculosis patients,72 cases(30.38%)were resistant to the four kinds of anti-TB drugs.The resistance mutation rate of rifampin,isoniazid and streptomycin was 2.53%, 13.92%,3.80%.The top 5 gene mutation detection loci of Mycobacterium tuberculosis were-15M,S531L and 43M.Conclusion The main drug-resistant strains are isoniazid resistance,and the mutation of inhA gene were the major one in Qinzhou,Guangxi.