1.MRI Diagnosis of Achilles Tendon Rupture
Jianrong XU ; Wan WANG ; Hongyuan HE ; Zhuhua ZHU ; Ruihua QIAO
Journal of Practical Radiology 2001;0(09):-
Objective To analyze the diagnostic methods of Achilles tendon rupture by MRI.Methods All 16 cases with Achilles tendon rupture were examined with sagital T 1,2 WI and axial T 1WI imaging.4 cases were appended Gd-DTPA enhancement.6 cases were followed up with MRI after 6~8 weeks.Results MRI appearance of Achilles tendon rupture represented Achilles tendon thickening,decrescent ratio of wide/vertical survey,hyperintensity in tendon,discontinuous fibrous bundle,fluid collected around tendon comparing with of normal Achilles tendon.Conclusion MRI is an valuable tool for the diagnosis of Achilles tendon rupture.
2.Effect of calcium cyanamid synthetic drug on Schistosoma japonicum egg morphology
Yisheng ZHOU ; Guohua PENG ; Zhuhua HU ; Xiaowu FENG ; Rong ZHU ; Wangyuan WEI ; Jiagang GUO
Chinese Journal of Schistosomiasis Control 2015;(1):56-58
Objective To study the morphological change of Schistosoma japonicum eggs processed by calcium cyanamide synthetic drug,so as to provide the basis for further study of the mechanism that calcium cyanamide synthetic drug to schisto?some eggs. Methods The calcium cyanamide synthetic drug was added to the cattle feces containing schistosome eggs and mixed up,and then the cattle feces was stacked as original shape on the marshland. Blank controls were set at the same time. The cattle feces samples were collected and the schistosome eggs were observed under a microscope on the 1st,2nd,3rd,7th day after the experiment. Results By the effect of calcium cyanamide synthetic drug,the color of eggs was deepening gradual?ly,the miracidia were atrophied,and the shells of eggs were thickened. The embryonic membrane of miracidia was no longer completed 3 days later,and the miracidia were deformed severely 7 days later. The atrophy of miracidia was not obvious in the blank controls. Conclusion The schistosome miracidia and embryonic membrane can be damaged by the calcium cyanamide synthetic drug,and worse damaged with time extending.
3.Evaluation of synchronous bilateral primary breast cancer by MRI and pathology
Yue YANG ; Yuping PAN ; Chungen WU ; Zhuhua ZHU ; Wenbin LI ; Qin HUANG
Journal of Practical Radiology 2016;32(3):358-361
Objective To analyze the magnetic resonance imaging (MRI)and histologic features of the synchronous bilateral primary breast cancer (sBPBC).Methods MRI findings and pathologic types of sBPBC in 20 patients in our institute were reviewed retrospectively. The MRI features of sBPBC were compared with the pathologic types,respectively.Results 20 sBPBC patients with 41 lesions were found with the most common pathological type of invasive ductal carcinoma in 26 (26/41 ).Bilateral lesions had the same pathological types in 1 1 patients(1 1/20),and different types in 9(9/20).The MRI features of invasive breast cancer were more characteristic than that of early breast cancer.In 20 patients,the first and second primary breast cancers with similar MRI findings were found in 6(6/20).In 10 patients with sBPBC,the first cancer was advanced breast cancer,and the second was early or low grade breast cancer.Conclusion (1)The most common pathological type of sBPBC is invasive ductal carcinoma,and the pathological types of bilateral lesions are not similar. (2)The MRI features of the first and the second lesions in bilateral primary breast cancer showed lower similarity,and the bilateral lesions should be diagnosed independently.(3)In patients with sBPBC,some cancers are advanced breast cancers,and the second ones are early cancers,suggesting the lesion should be followed up if the contralateral one is diagnosed as breast cancer.
4.Coronary Artery Imaging in Patients with High Heart Rate by Dual-source CT:The Initial Experience
Zhuhua ZHANG ; Zhengyu JIN ; Shuyang ZHANG ; Songbai LIN ; Dongjing LI ; Lingyan KONG ; Yining WANG ; Lan SONG ; Yun WANG ; Wenmin ZHAO ; Linhui WANG ; Xiaona ZHANG ; Yunqing ZHANG ; Bing QI ; Kai XU ; Jixiang LIANG ; Haifeng ZHU ; Wenbin MOU ; Liren ZHANG ; Wenling ZHU ; Qi MIAO ; Qi FANG
Journal of Practical Radiology 2001;0(08):-
Objective To explore the scanning technique and image quality of coronary artery imaging with dual-source CT without oral Betaloc preparation in the patients with high heart rate.Methods 412 cases were undergone coronary imaging with dual-source CT (including plain and enhanced scans) ,among them,there were 30 cases with heart rate more than 100 bpm.Multi-planar reconstruction(MPR),maximum intensity projection(MIP) and volume rendering (VR) were performed using contrast-enhanced images.The image quality was classified into 3 grades, and coronary segments named according to AHA standard were evaluated.Results The average heart rate during enhanced scan in the 30 cases was (115.6?11.8)(101~139)bpm,the average breath hold time was (5.7?1.2) s.The best reconstruction phase was in the systolic phase. Altogether 424 coronary segments were evaluated, among them 93.9%(398/424)belonged to the first grade,5.0%(21/424)belonged to the second grade,and 1.2%(5/424) belonged to the third grade. Conclusion Without oral administration of Betaloc preparation, good coronary artery images can be obtained in the patients with high heart rate by dual-source CT.
5.Analysis of chest imaging features of novel coronavirus pneumonia, bacterial pneumonia and viral pneumonia
Yufang CAO ; Xiaozhi WANG ; Xiaohong XIE ; Jinghui LI ; Chao DENG ; Xiangying LI ; Zhuhua ZHU ; Zhidian WU ; Chao JI ; Yi NIU ; Fan LIU ; Yanmei YU ; Wei SONG
Chinese Critical Care Medicine 2023;35(1):28-31
Objective:To investigate and summarize the chest CT imaging features of patients with novel coronavirus pneumonia (COVID-19), bacterial pneumonia and other viral pneumonia.Methods:Chest CT data of 102 patients with pulmonary infection due to different etiologies were retrospectively analyzed, including 36 patients with COVID-19 admitted to Hainan Provincial People's Hospital and the Second Affiliated Hospital of Hainan Medical University from December 2019 to March 2020, 16 patients with other viral pneumonia admitted to Hainan Provincial People's Hospital from January 2018 to February 2020, and 50 patients with bacterial pneumonia admitted to Haikou Affiliated Hospital of Central South University Xiangya School of Medicine from April 2018 to May 2020. Two senior radiologists and two senior intensive care physicians were participated to evaluated the extent of lesions involvement and imaging features of the first chest CT after the onset of the disease.Results:Bilateral pulmonary lesions were more common in patients with COVID-19 and other viral pneumonia, and the incidence was significantly higher than that of bacterial pneumonia (91.6%, 75.0% vs. 26.0%, P < 0.05). Compared with other viral pneumonia and COVID-19, bacterial pneumonia was mainly characterized by single-lung and multi-lobed lesion (62.0% vs. 18.8%, 5.6%, P < 0.05), accompanied by pleural effusion and lymph node enlargement. The proportion of ground-glass opacity in the lung tissues of patients with COVID-19 was 97.2%, that of patients with other viral pneumonia was 56.2%, and that of patients with bacterial pneumonia was only 2.0% ( P < 0.05). The incidence rate of lung tissue consolidation (25.0%, 12.5%), air bronchial sign (13.9%, 6.2%) and pleural effusion (16.7%, 37.5%) in patients with COVID-19 and other viral pneumonia were significantly lower than those in patients with bacterial pneumonia (62.0%, 32.0%, 60.0%, all P < 0.05), paving stone sign (22.2%, 37.5%), fine mesh sign (38.9%, 31.2%), halo sign(11.1%, 25.0%), ground-glass opacity with interlobular septal thickening (30.6%, 37.5%), bilateral patchy pattern/rope shadow (80.6%, 50.0%) etc. were significantly higher than those of bacterial pneumonia (2.0%, 4.0%, 2.0%, 0%, 22.0%, all P < 0.05). The incidence of local patchy shadow in patients with COVID-19 was only 8.3%, significantly lower than that in patients with other viral pneumonia and bacterial pneumonia (8.3% vs. 68.8%, 50.0%, P < 0.05). There was no significant difference in the incidence of peripheral vascular shadow thickening in patients with COVID-19, other viral pneumonia and bacterial pneumonia (27.8%, 12.5%, 30.0%, P > 0.05). Conclusions:The probability of ground-glass opacity, paving stone and grid shadow in chest CT of patients with COVID-19 was significantly higher than those of bacterial pneumonia, and it was more common in the lower lungs and lateral dorsal segment. In other patients with viral pneumonia, ground-glass opacity was distributed in both upper and lower lungs. Bacterial pneumonia is usually characterized by single lung consolidation, distributed in lobules or large lobes and accompanied by pleural effusion.
6.Third-generation Dual-source CT for Head and Neck CT Angiography with 70 kV Tube Voltage and 20-25 ml Contrast Medium in Patients With Body Weight Lower than 75 kg.
Yu CHEN ; Yuanli ZHU ; Huadan XUE ; Yun WANG ; Yumei LI ; Zhuhua ZHANG ; Zhengyu JIN
Acta Academiae Medicinae Sinicae 2017;39(1):4-8
Objective To investigate the image quality of head and neck CT angiography (CTA)using the third-generation dual-source CT combined with 70 kV tube voltage and 20-25 ml contrast medium (CM),and evaluate the effects of venous artifacts arising from the CM on the ipsilateral side of injection. Methods Totally 40 consecutive patients with suspected vascular diseases and body weight lower than 75 kg prospectively underwent head and neck CTA examination using the third-generation dual-source CT. CTA was performed with a third-generation dual-source CT system. Patients were randomly divived into 70 kV group (n=20)and 100 kV group (n=20). The 70 kV group used 20-25 ml CM and advanced modeled iterative reconstruction technique,and the 100 kV group used 40 ml CM and filtered back projection. Venous artifacts and CM residues were evaluated by a 3-point scale (1=excellent,3=poor),respectively. Results The effective dose of 70 kV group decreased 58% compared to 100 kV group (t=-18.14,P<0.001).In the 70 kV group,16 patients (80.0%)presented with venous artifacts and six of them (37.5%,6/16)affected the adjacent arteries. In the 100 kV group,19 patients (95.0%)presented with venous artifacts,and seven of them (36.8%,7/19)affected the adjacent arteries (Z=-0.878,P=0.380). In the 70 kV group,13 patients (65.0%)presented with obvious CM residues and two of them (15.3%,2/13)prolonged into the superior vena cava (SVC). In the 100 kV group,19 patients(95.0%)presented with obvious CM residues,and thirteen of them(68.4%,13/19)prolonged into the SVC (Z=-3.654,P<0.001). Conclusion Compared with the 100 kV,the third-generation dual-source CT for head and neck CTA,combined with 70 kV and 20-25 ml CM,can remarkably decrease the radiation dose,along with reduced CM residues and comparable venous artifacts.
Artifacts
;
Body Weight
;
Computed Tomography Angiography
;
methods
;
Contrast Media
;
Head
;
diagnostic imaging
;
Humans
;
Neck
;
diagnostic imaging
;
Radiation Dosage
;
Radiographic Image Interpretation, Computer-Assisted
7.Application of Third-generation Dual-source CT for Ultra-high Resolution Temporal Bone Imaging Using Automated Tube Voltage Adaptation in Children with Hearing Impairment.
Yuanli ZHU ; Yu CHEN ; Xinmiao FAN ; Huadan XUE ; Xiaowei CHEN ; Man WANG ; Yun WANG ; Zhuhua ZHANG ; Zhengyu JIN
Acta Academiae Medicinae Sinicae 2017;39(1):12-16
Objective To evaluate the radiation dose and image quality of the third-generation dual-source CT using automated tube voltage adaptation (CARE kV) in temporal bone scanning in pediatric patients with hearing impairment. Methods Totally 27 children with hearing impairment less than 18 years old were randomly divided into two groups:Group A (n=14),examined with CARE kV (reference with 100 kV and 214 mA)and sinogram-affirmed iterative reconstruction;and Group B (n=13),examined with CARE kV (reference with 100 kV and 171 mA)and advanced modeled iterative reconstruction. The scan range was from eyebrow to the end of the mastoid process. CT values and image noise were measured.The signal to noise ratio (SNR)was calculated. Subjective image quality was assessed by two radiologists and later in a consensus reading. Results There was no significant difference in CT value,image noise,and SNR between these two groups (all P>0.05). Also,the subjective scores of the 10 anatomical structures showed no significant difference (all P>0.05). The CT dose index volume and dose-length product were (11.62+1.92)mGy and (106.92+37.48)mGy·cm,respectively,in group B and (21.28+2.19)mGy (t=12.15,P<0.001)and (229.65+56.26)mGy·cm (t=6.62,P<0.001)in group A,decreased by 45% and 53%. Conclusion Compared with the second-generation dual-source CT,the third-generation dual-source CT for the scanning of temporal bone with CARE kV can ensure image quality and reduce radiation dose.
Child
;
Hearing Loss
;
diagnosis
;
Humans
;
Radiation Dosage
;
Radiographic Image Interpretation, Computer-Assisted
;
Signal-To-Noise Ratio
;
Temporal Bone
;
diagnostic imaging
;
Tomography, X-Ray Computed
;
methods