1.Study on cardiac torsional deformation in patients with dilated cardiomyopathy by velocity vector imaging
Guohui YAN ; Guang ZHI ; Yong XU ; Xiao ZHOU ; Saijun HOU
Chinese Journal of Ultrasonography 2008;17(5):378-380
Objective To characterize the systolic torsion in dilated cardiomyopathy (DCM) by velocity vector imaging(VVI).Methods Eighty-seven subjects were studied using VVI:27 patients with DCM and 60 healthy control subjects.Left ventricular short-axis acoustic images were acquired at base and apex levels.The rotation angle and rotation velocity of endocardium and epicardium were measured.Results LVEF of DCM group was significantly lower than that of control group ( P<0.01).The basal and apical rotation angle, rotation velocity were significantly lower in DCM group.The endocardial and epicardial rotation angle, rotation velocity were also significantly lower in DCM group than those in control group (P<0.01).Conclusions VVI is a rapid and noninvasive tool to quantitatively assess cardiac torsional deformation in DCM patients,which providing another useful modality for evaluating cardiac function.
2.Quantitative analysis of strain and strain rate of right ventricular in normal subjects by velocity vector imaging
Haijun HOU ; Guang ZHI ; Xiaojuan ZHANG ; Xiao ZHOU ; Yong XU
Chinese Journal of Ultrasonography 2008;17(4):281-283
Objective To investigate strain and strain rate of right ventricular(RV)based on twodimensional image by velocity vector imaging in normal subjects.Methods Thirty-two healthy adults were rolled in this study.Echocardiographic images in 4 chamber view were analyzed by conventional manual tracing for volumes and ejection fractions,which were also measured by velocity vector imaging.Myocardial velocity,strain rate,and strain were determined at the basal,mid,and apical segments of the RV free wall and ventricular septum by velocity vector imaging.Results RV ejection fractions obtained with manual tracing correlated strongly with the same indexes obtained by velocity vector imaging method in all subjects(r=0.91,P<0.01).The strain and strain rate value of middle segment and basal segment in RV free wall were higher than those of apical segment.There were same trend in ventricular septal.The strain and strain rate of middle segment and basal segment in RV free wall were higher than those of homologous segments in ventricular septal,but the indexes of apical segment in free wail and septal had no difference.The strain and strain rate in RV were not correlated with age.Conclusions Velocity vector imaging could accurately and quantitatively assess the strain and strain rate of RV.
4.Detective Significance of Cerebral Electrical Admittance Plethysmogram in Newborns with Asphyxia
ke-ying, ZHOU ; jin-zhi, SONG ; jing-zhi, LI ; hui, LUO ; xue-chang, XIAO ; zhi-guang, LI ; ben-qing, WU
Journal of Applied Clinical Pediatrics 2006;0(20):-
Objective To study hemodynamics of cerebral blood flow in newborns with asphyxia.Method Bilateral cerebral electrical admittance plethysmogram(BCEAP) was used to explore characteristics of cerebral blood flow in 20 healthy newborns and 20 newborns with asphyxia respectively from first to fourth day after birth.Results Both the ratio of Hs to b-S(Hs/ b-S) and index of admittance differential loop(ADL) Ⅰ+Ⅱ decreased significantly in newborns with asphyxia compared to normal control from first to fourth day after birth(P
5.Synthesis and activity evaluation of PARP-1 inhibitors with azaindole skeleton.
Jie ZHOU ; Zhi-Xiang ZHU ; Xiao-Guang CHEN ; Bai-Ling XU
Acta Pharmaceutica Sinica 2013;48(12):1792-1799
PARP [poly(ADP-ribose)polymerase] represents a novel potential target in cancer therapy. It is involved in a DNA repair process by catalyzing the transfer of ADP-ribose units from NAD to a number of its substrate proteins. In this work, a series of novel azaindole derivatives was designed and synthesized. Moreover, 16 target molecules were screened and 8 compounds displayed inhibitory activity against PARP-1. It has been demonstrated that these azaindoles bearing cycloamine substituents at 2-position were active to both PARP-1 and PARP-2.
Antineoplastic Agents
;
chemical synthesis
;
chemistry
;
pharmacology
;
Aza Compounds
;
chemical synthesis
;
chemistry
;
pharmacology
;
Indoles
;
chemical synthesis
;
chemistry
;
pharmacology
;
Poly (ADP-Ribose) Polymerase-1
;
Poly(ADP-ribose) Polymerases
;
metabolism
8.A rare case of isolated non-compaction right ventricular myocardium.
Xiao-juan ZHANG ; Guang ZHI ; Hai-jun HOU ; Xiao ZHOU
Chinese Medical Journal 2009;122(14):1718-1720
10.Micro-plate radiobinding assay of autoantibody to glutamic acid decarboxylase
Can, HUANG ; He-lai, JIN ; Xia, WANG ; Hui, LI ; Song, ZHANG ; Zhi-guang, ZHOU
Chinese Journal of Nuclear Medicine 2008;28(5):339-343
Objective The purpose of this study was to develop a high-throughput micro-plate radiobinding assay (RBA) of glutamic acid decarboxylase antibody (GAD-Ab) and to evaluate its clinical application. Methods 35labeled GAD65 antigen was incubated with sera for 24 h on a 96-well plate, and then transferred to the Millipore plate coated with protein A, which was washed with 4℃ PBS buffer, and then counted by a liquid scintillation counter. The GAD-Ab results were expressed by WHO standard unit (U/ml). A total of 224 healthy controls, 162 patients with type 1 diabetes mellitus(T1DM) and 210 patients with newly diagnosed type 2 diabetes (T2DM) were recruited. A total of 119 TI DM and healthy cases with gradually changing GAD-Ab levels were selected to compare the consistency of micro-plate RBA with conventional radioligand assay (RLA). Blood samples were obtained from the peripheral vein and finger tip in 32 healthy controls, 35 T1DM and 24 T2DM patients, and tested with micro-plate RBA and then compared with the conventional RLA to investigate the reliability of finger tip sampling. Linear correlation,student's t-test, variance analysis and receiver operating characteristic (ROC) curve were performed using SPSS 11.5. Results (1) The optimized conditions of micro-plate RBA included 2 μl serum incubated with3 ×104 counts/min 35S-GAD for 24 h under slow vibration, antigen-antibody compounds washed 10 times by 4℃ PBS buffer, and radioactivity counted with Optiphase Supermix scintillation liquid. (2)The intra-batch CV of the micro-plate RBA was 3.8%- 10.2%, and the inter-batch CV was 5.6%- 11.9%. The linearity analysis showed a good correlation when the GAD-Ab in serum samples ranged from 40.3 to 664 U/ml and the detection limit of measurement was 3.6 U/ml. The results from Diabetes Autoantibody Standardization Program (DASP) 2005 showed that the sensitivity and specificity for GAD-Ab were 78% (39 positive among 50 new-onset T1DM) and 98% (2 positive among 100 healthy controls). The results of GAD-Ab obtained with micro-plate RBA and RLA were closely correlated (r=0.915,P<0.001) with a high concordance level of 97.5% and a Kappa value of 0.95. (3)TI DM and T2DM patients showed higher positive rates for GAD-Ab than the healthy controls(46.9% and 5.2% vs 0.89% ,X2=123.5 and 10. 1 ,P <0.001 and <0.01, respectively). (4)The consistency of GAD-Ab measurement with RBA using finger tip blood and RLA measurement using venous blood was 96.7% (r =0.946,P <0.001, Kappa value: 0.905). Conclusions The micro-plate RBA of GAD-Ab has high sensitivity, specificity and reproducibility, and can be measured with finger tip blood sampling. It might be a better alternative for clinical practice.