1.Survey and Discussion on VentiIator AIarm Status in ICU
Zhongkuan LIN ; Kun ZHENG ; Yunming SHEN ; Caixian ZHENG ; Xiaoying CHENG
Chinese Journal of Medical Instrumentation 2017;41(6):460-463
Objective The article aims at survey and analysis on ventilator alarm status in pediatric hospital. Methods First,we design the statistical table of ventilator, and analyze the reliability of statistical table. Then we evaluate the effectiveness of the alarm. Finally, we evaluate the alarm information synthetically through investigation and statistics.Results The ventilator alarm is ineffective, a large number of nonsensical alarms, leading to lower alert sensitivity of medical staff. Conclusion According to the survey results, we should analyze the cause of the problem, and propose the corresponding alarm management method.
2.Hospital Networked Medical Equipment Safety Management.
Mangmang ZHANG ; Kun ZHENG ; Yunming SHEN ; Zhongkuan LIN ; Zheming LI
Chinese Journal of Medical Instrumentation 2018;42(4):303-304
With the continuous improvement and wide application of hospital information, more and more medical equipment is integrated into the hospital information systems, which brings new work contents and challenges for the traditional clinical engineers. This paper reviews and evaluates the current situation of networked medical equipment in the hospital. By applying the ISO 80001 and the MDS(Manufacturer Disclosore Statement for Medical Device Security), the paper puts forward the measures and suggestions for the security management of networked medical equipment.
Equipment Safety
;
Equipment and Supplies
;
Hospital Information Systems
;
Safety Management
3.Research on the Clinical Alarm Management Mechanism Based on Closed-loop Control Theory.
Zhongkuan LIN ; Kun ZHENG ; Yunming SHEN ; Yunyun WU
Chinese Journal of Medical Instrumentation 2018;42(3):173-175
This paper proposes a clinical alarm management system based on the theory of the closed loop control. The alarm management mechanism can be divided into the expected standard, improving execution rule, rule execution, medical devices with alarm functions, results analysis strategy and the output link. And, we make relevant application and discussion. Results showed that the mechanism can be operable and effective.
Clinical Alarms
;
Decision Support Systems, Clinical
4.Empirical Study on the Impact of Infusion Media on the Flow Rate of Infusion Pumps
Ning YAO ; Li BAO ; Zhongkuan LIN ; Yunming SHEN ; Kun ZHENG
Chinese Journal of Medical Instrumentation 2024;48(4):430-433
Objective To investigate the impact of different infusion media on the flow rate of infusion pumps.Methods Ten infusion pumps were randomly selected and tested for infusion rates using deionized water,saline solution,glucose solution,and parenteral nutrition solution.The infusion flow rate was set at 30 mL/h,and the testing methodology conformed to the standards for the calibration and quality control of syringe pumps and infusion pumps.Results For infusion set A,the infusion rate was unaffected by the infusion media,remaining within the acceptable quality control standards.For infusion set B,when infused with deionized water,saline solution,and glucose solution,the infusion errors were within the quality control standards.However,when using parenteral nutrition solution as the infusion medium,the infusion error exceeded the acceptable quality control standards.Conclusion Both the infusion set and the infusion medium can affect the flow rate of infusion pumps.It is crucial to calibrate the flow rate according to the specific infusion medium to reduce medical risks associated with infusion pumps during clinical use.