1.Expression of TIP30 and its correlation with angiogenesis in gastric cancers
Zhongkai XU ; Chunning ZHENG ; Shaochuan SUN ; Yongsheng JIANG
Chinese Journal of Current Advances in General Surgery 1999;0(02):-
Objective:To investigate the expression of TIP30 in gastric cancer tissues and analyze its impact with angiogenesis. Methods: The expression of TIP30 and CD34-labeled mi-crovessel density (MVD)were measured by immunohistochemical staining in 52 cases of gastric carcinomas and 47cases of Para-cancer tissues. Results: the positive rate of TIP30 was 53.8% and 85.1% in cancerous tissues and para- cancer tissues, there were significant differences between them(?2=11.22,P
2.A simple and effective anti-backflow positioning evaluation device for orotracheal intubation in rats
Lizhi BAO ; Yufeng ZHU ; Mengni JIANG ; Jingwen SONG ; Zhongkai WANG ; Fang CHENG ; Zhifu GUO ; Xing ZHENG
Chinese Journal of Comparative Medicine 2017;27(8):70-74
Objective To improve the orotracheal intubation verifying technique and reduce the complication of backflow in rat experiment.Methods A new position evaluation of anti-backflow device was designed and made of safety IV catheter and closed IV catheter system.60 adult male Sprague Dawley rats 216±20 g were randomly assigned to two groups: group A (n=40) for verifying placement, group B (n=20) for anti-backflow test.Group A was further divided into group A1 using self-designed positioning device, group A2 using aerosol, group A3 taking cotton fiber for positioning judgment.The group B was divided into two subgroups, B1 and B2, counting escaped bubbles as a means of positioning observation, the difference is that group B1 using frustum of a cone shape anti-backflow device, while the group B2 using common airway tube.Routine endotracheal intubation was performed to observe and record the time of positioning, the location of exhalation phase, and the length of inspiratory phase countercurrent water column.The group A1 further performed tracheotomy under direct vision clearly to confirm the anatomic positioning status.Results During the exhalation cycle,three or more bubbles were observed to escape continuously, indicating that the intubation tube was properly placed and open in the airway.Positioning time: It took 1.75±1.02 respiratory cycles in group A1,3.30±0.95 respiratory cycles in group A2 and 4.10±0.99 respiratory cycles in group A3 to complete the assessment the positioning status.There was no statistically significant difference between groups A2 and A3 (P> 0.05).The time needed for group A1 was significantly shorter than that of groups A2 and A3 (P < 0.01).The longest countercurrent water column length in group B1 was 3.23±0.53 cm, and 8.48±1.01 cm in the group B2.Conclusions The new designed anti-backflow positioning evaluation device is a simple and convenient appliance to evaluate the location of orotracheal intubation in rat experiment.It can effectively improve the positioning efficiency and has practical application value.
3.Evaluation of Cone Beam CT Image Quality and Analysis of Its Long-term Stability on HU Values under Different Conditions
Hanshun GONG ; Wei XU ; Shouping XU ; Chuanbin XIE ; Tao YANG ; Xiaohu CONG ; Xiaoshen WANG ; Zhongkai JIANG
Chinese Journal of Medical Instrumentation 2016;40(2):86-89,94
Objective To evaluate the cone beam CT (CBCT) image quality and its long-term stability for HUs under different scanning conditions.Methods With the OBI system, Catphan 504 phantom using the different modes was scanned through one year. Analysis of variance (ANOVA) was used to evaluate the CBCT images.Results The results of contrast resolution under different scanning conditions met the requirements of acceptance test procedure. Spatial contrast resolution(≥5 lp/cm) of half-fan scanning conditions were inferior to those (≥7 lp/cm) of ful-fan mode. The accuracies of spatial linear distance and angle were within±1%. HUs in air density plug were constant, but HUs of other plugs with different conditions had the signifi cant difference (F=660.84,P=0). Under different conditions in a year, the mean HUs showed a good agreement.Conclusions HUs of CBCT image under different scanning conditions exist a little difference, but there is a good consistency for the long term stability analysis. It is helpful for CBCT images directly used for dose re-calculation in adaptive radiation therapy (ART).
4.Evaluation of the EDOSE for IMRT Delivery Quality Assurance
Xiaoshen WANG ; Zhongjian JU ; Wei XU ; Hanshun GONG ; Zhongkai JIANG ; Xiaohu CONG
Chinese Journal of Medical Instrumentation 2016;40(2):147-149
Objective Evaluation of intensity-modulated radiation therapy(IMRT) delivery quality assurance(DQA) using EDOSE software based on accelerator electronic portal imaging device (EPID).Methods Analysed the dose response uniformity correction of EPID imaging plate in different fields and the gamma pass rates about the fields; And compared the calculated parameters of the EDOSE and the Pinnacle planning station.Results The uniformities on the homogeneous region of thefi elds are good after who corrected by EDOSE. The gamma(γ, 3mm/3%) pass rates are in the ideal range. The volume of the organs at risk(OAR) have no statistical signifi cance except the right lung; A part of the parameters have statistical signifi cance.Conclusions The results of the calculation and analysis of EDOSE has a high agreement with the planning system.
5.Efficacy of O-arm combined with CT three-dimensional navigation system assisted versus manual screw placement in the treatment of lower cervical fracture and dislocation
Shuai LI ; Jinpeng DU ; Jiang WANG ; Yunfei HUANG ; Zhigang ZHAO ; Zhen CHANG ; Xuefang ZHANG ; Liang YAN ; Hua HUI ; Xiaobin YANG ; Zhongkai LIU ; Lingbo KONG ; Bolong ZHENG ; Baorong HE
Chinese Journal of Trauma 2023;39(8):712-720
Objective:To compare the clinical efficacies of O-arm combined with CT three-dimensional navigation system assisted screw placement versus manual screw placement in treating lower cervical fracture and dislocation.Methods:A retrospective cohort study was used to analyze the clinical data of 41 patients with lower cervical fracture and dislocation, who were treated in Honghui Hospital, Xi′an Jiaotong University from May 2021 to February 2022. The patients included 26 males and 15 females, aged 31.5-48.6 years [(41.5±15.0)years]. The injured segments were C 3 in 3 patients, C 4 in 12, C 5 in 13, C 6 in 10 and C 7 in 3. Nineteen patients were treated with cervical pedicle screws by O-shaped arm combined with CT three-dimensional navigation system (navigation group, 76 screws) and 22 by bare hands (traditional group, 88 screws). The total operation time, effective operation time, single nail placement time, single screw correction times, screw distance from anterior cortex, intraoperative blood loss, intraoperative fluoroscopic radiation dose, incision length and length of hospital stay were compared between the two groups, and the height of intervertebral space, Cobb angle, interbody slip distance and American Spinal injury Association (ASIA) grade were compared before operation and at 3 days after operation. Visual analogue score (VAS), Japanese Orthopedic Association (JOA) score, and neck dysfunction index (NDI) were evaluated before operation, at 3 days, 3 months after operation and at the last follow-up. Accuracy of screw placement and incidence of complications (adjacent facet joint invasion, infection, screw loosening) were detected as well. Results:All the patients were followed up for 11.1-13.9 months [(12.5±1.4)months]. The total operation time, intraoperative blood loss, intraoperative fluoroscopic radiation dose and incision length in the navigation group were more or longer than those in the traditional group (all P<0.05). The effective operation time, single nail placement time, single nail correction times and screw distance from anterior cortex in the navigation group were markedly less or smaller than those in the traditional group (all P<0.05). There was no significant difference in the length of hospital stay between the two groups ( P>0.05). There were significant improvements in the height of intervertebral space, Cobb angle and interbody slip distance between the two groups at 3 days after operation (all P<0.05). There was no significant difference in the height of intervertebral space, Cobb angle, interbody slip distance or ASIA grade between the two groups before operation or at 3 days after operation (all P>0.05). Compared with pre-operation, the VAS, JOA score and NDI were significantly improved in both groups at 3 days, 3 months after operation and at the last follow-up (all P<0.05), with further improvement with time. There was no significant difference in VAS between the two groups before operation or at 3 months after operation (all P>0.05), but it was markedly lower in the navigation group compared with the traditional group at 3 days after operation and at the last follow-up (all P<0.05). There were no significant differences in JOA score or NDI between the two groups before operation or at 3 days and 3 months after operation (all P>0.05), but both were lower in the navigation group compared with the traditional group at the last follow-up (all P<0.05). The accuracies of placement of grade 0 and grade 0+1 screws were 92.0% (70/76) and 96.6% (73/76) in the navigation group, respectively, which were markedly higher than 88.7% (78/88) and 93.5% (82/88) in the traditional group (all P<0.05). The rates of adjacent facet joint invasion of A, B, and C degrees were 71.2% (54/76), 28.8% (22/76) and 0% (0/76) in the navigation group, respectively, while the invasion rates were 60.5% (53/88), 32.3% (28/88) and 7.3% (7/88) in the traditional group ( P<0.05). No screw loosening was noted in the navigation group, but the screw loosening rate was 9.1% (8/88) in the traditional group ( P<0.01). Conclusion:Compared with manual screw placement, O-arm combined with CT three-dimensional navigation system assisted screw placement for lower cervical fracture and dislocation has the advantages of shorter effective operation time, quicker screw placement, stronger screw holding force, better cervical stability, slighter postoperative pain, higher screw placement accuracy, and lower facet joint invasion and screw loosening rates.
6.Establishment, validation and application of fluorescence focus assay for rapid titration of Japanese encephalitis virus
Na LUO ; Jian QIAO ; Zhijun JIANG ; Shantang YANG ; Zhongkai ZHANG ; Jie WU ; Gelin XU
Chinese Journal of Microbiology and Immunology 2022;42(3):224-233
Objective:To establish and validate a fluorescence focus assay (FFA) for rapid titration of Japanese encephalitis virus (JEV) and to evaluate its application in the production of Japanese encephalitis vaccine.Methods:Recombinant JEV non-structural protein 1 (NS1) was expressed in a prokaryotic expression system. After purification, JEV-NS1 was used to immunize rabbits to induce polyclonal antibody. FFA was established with the polyclonal antibody to titer JEV. The accuracy of FFA was validated by comparing with plaque assay, and the specificity, precision, linearity, range and robustness of FFA were also validated. Twenty-eight batches of live-attenuated Japanese encephalitis vaccine were titrated with FFA and plaque assay to analyze the relationship between the two assays.Results:FFA established with polyclonal antibody against JEV-NS1 could be used to titrate JEV, and there was no cross reaction with other viruses (tick-borne encephalitis virus, yellow fever virus, coxsackievirus A2, coxsackievirus A4). Results of the validation tests showed that FFA met the requirement of quality control for live-attenuated Japanese encephalitis vaccine. FFA was more consistency than plaque assay.Conclusions:The established FFA could be used for virus titration in the production of live-attenuated Japanese encephalitis vaccine.
7.Chinese surgical robot-assisted surgery for parotid tumor:a case report
Guiquan ZHU ; Zhongkai MA ; Chang CAO ; Jialu HE ; Jiawei HONG ; Ruiting REN ; Hui XIA ; Bing YAN ; Xiaoyi WANG ; Long-Jiang LI ; Chunjie LI
West China Journal of Stomatology 2024;42(2):262-267
Robotic surgery is known as the"third technological revolution"in the field of surgery,and is an important milestone in the development of modern surgery.However,our country's innovative surgical robot industry is still in its early stages,and it is only being utilized in certain surgical fields.To explore the effectiveness of the application of do-mestic surgical robot in oral and maxillofacial surgery,the author successfully completed a case of benign parotid tumor resection with the assistance of a domestic autonomous robot.The operation was successful,facial nerve function was preserved,and postoperative wound healing was good.