1.Therapeutic Observation of Abdominal Electroacupuncture plus Chinese Medicinal Application at Umbilicus for Poststroke Constipation
Zhonghui XIONG ; Xin GONG ; Tianjiao LU
Shanghai Journal of Acupuncture and Moxibustion 2017;36(3):265-268
Objective To observe the clinical efficacy of abdominal electroacupuncture plus umbilicus application with Chinese medication in treating poststroke constipation.Method A total of 160 patients with poststroke constipation were randomized into a treatment group and a control group, 80 cases in each group. The treatment group was intervened by abdominal electroacupuncture plus umbilicus application with Chinese medication, while the control group was intervened by oral administration of Phenolphthalein tablets. The constipation symptoms scores were observed before and after the treatment, and the clinical efficacies were compared.Result In the treatment group, the constipation symptoms scores were significantly changed after the treatment (P<0.05). In the control group, the scores of defecation duration and abdominal bloating were significantly changed after the treatment (P<0.05). The constipation scores in the treatment group were significantly different from those in the control group after the treatment (P<0.05). The recovery rate and total effective rate were respectively 66.3% and 92.5% in the treatment group, versus 40.0% and 78.8% in the control group, and the between-group differences were statistically significant (P<0.05). Conclusion Abdominal electroacupuncture plus umbilicus application with Chinese medication is an effective method in treating poststroke constipation.
2.THE ANTITUMOR EFFECT OF POLYPHASE LIPOSOME OF LINOLEIC ACID CONTAINING SELENIUM
Shaoan XUE ; Baolin LI ; Zhonghui WANG ; Dengsi LU ; Jingyi TAO ;
Acta Nutrimenta Sinica 1956;0(01):-
70%, P143%, p
3.A study on individual internal fixation with steel plate according to 3D reconstruction of CT images and Ugnx, Pro/E machining method.
Zhonghui LU ; Songlin TONG ; Zhongmian XU
Chinese Journal of Medical Instrumentation 2010;34(2):89-93
PURPOSEDiscuss the new method of individual internal fixation with steel plate customization.
METHODCustomize individual internal fixation with steel plate according to 3D reconstruction of CT images and Ugnx. Pro/E machining method.
RESULTSuccess in customization about the first individual internal fixation with clavicular hook plate for the treatment of multisegmental fracture of clavicle.
CONCLUSIONThe new method of individual internal fixation with steel plate customization according to 3D reconstruction of CT images and Ugnx, Pro/E machining technique is a good news for patients of orthopaedic trauma. We are fully confident of the future development of the method of individual internal fixation with steel plate customization.
Bone Plates ; Equipment Design ; Fracture Fixation, Internal ; instrumentation ; Fractures, Bone ; diagnostic imaging ; Humans ; Image Processing, Computer-Assisted ; methods ; Imaging, Three-Dimensional ; Internal Fixators ; Steel ; Tomography, Spiral Computed ; methods
4.The evaluation of fetal nasal bone absence at second and third trimester and its relationship with chromosomal abnormalities
Jia, LU ; Hua, MENG ; Yuxin, JIANG ; Qing, DAI ; Zhonghui, XU ; Meng, YANG ; Yunshu, OUYANG ; Yixiu, ZHANG
Chinese Journal of Medical Ultrasound (Electronic Edition) 2014;(6):502-507
Objective To evaluate the ultrasonic characteristics of nasal bone absence at 16-34 weeks of pregnancy referring to fetal chromosomal anomalies. Methods The ultrasonic findings of the 20 fetuses with nasal bone absence at second or third trimester in Peking Union Medical College Hospital were reviewed referring to chromosomal karyotyping and labor induction or birth outcomes. Results The ultrasound features of the 20 fetuses including:(1) There were 17 fetuses showed bilateral nasal bones absence. The sonographic features were absence of hyper echo of nasal bone underneath the skin on either sagittal or transverse section. There were 5 fetuses showed multiple abnormalities:Four fetuses showed cardiac abnormalities (three showed atrioventricular septal defect, one showed ventricular septal defect, one showed ventricular septal defect with abnormal great vessels). One fetus showed duodenal obstruction′double bulbs′. The other minor abnormalities including short femur and humerus, increasing echogenetic bowels, aberrant right subclavian artery, mild unilateral ventriculomegaly, mild renal pelvic ectasia, outreached tongue, abnormal gestures of hands. (2) There were 3 fetuses showed unilateral nasal bone absence. The sonographic features were absence of hyper echo of either nasal bone on transverse section but with hyper echo on sagittal section. Two fetuses showed cardiac abnormalities (one fetus showed atrioventricular septal defect, one showed ventricular septal defect). The other minor abnormalities including short femur and humerus, hyper echogenetic bowels, increasing thickness of nuchal translucency or nuchal fold. Twelve fetuses were induced labor but only one had biopsy showed accordant result with ultrasound. (3) Karyotyping results:there were 9 of trisomy 21, 1 of 4p-and 7 of normal karyotype fetuses showed bilateral nasal bone absence. There were 2 of trisomy 21 and 1 of normal karyotype fetuses showed unilateral nasal bone absence. (4) Birth outcomes and follow-up:twelve fetuses induced labor but only one fetus had biopsy. Eight fetuses were born until term and 5 fetuses showed normal in follow-up. The results of twelve fetuses showed concordant with ultrasonic ifndings. Conclusions Characteristics of the nasal bone absence are absence of bilateral or unilateral nasal bones. If we ifnd nasal bone absence in prenatally ultrasound screening, the karyotyping should be recommended in order to detect chromosomal abnormalities especially trisomy 21.
5.Correlation and regression analysis of placenta volume at 11-13+6 weeks of pregnancy with newborn baby weights, placenta weights and volumes at birth
Jia, LU ; Qing, DAI ; Hua, MENG ; Yuxin, JIANG ; Zhonghui, XU ; Meng, YANG ; Yunshu, OUYANG ; Yixiu, ZHANG
Chinese Journal of Medical Ultrasound (Electronic Edition) 2015;(2):142-147
Objective The aim of the study was to determine the placenta volume (PV) at 11-13+6 weeks of gestation by three-dimensional ultrasound (3DUS) in combination with birth weight, placenta weight, placenta volume at birth and maternal age, body mass index (BMI) additionally. Methods From June 2011 to July 2012, placental volumes were prospectively measured by VOCAL (Virtual Organ Computer-aided Analysis) method in 129 normal pregnancies of Peking Union Medical College Hospital at 11-13+6 weeks of Gestation, multiples of the median was calculated (MOM) after logarithmic10 transformation referring to different crown-rump length (CRL) groups. The normal pregnancies were selected without any combinations or fetal abnormalities, then recorded the birth weights, placenta diameters and thicknesses and placenta weight at delivery. The maternal basic status was also concluded in the study. Results Correlation analysis results: (1) The transformed placenta volume MOM showed a significant correlation (Spearman rho=0.200, P<0.05) with birthweight but not with placenta weight or placenta volume calculated as ellipsoid (Spearman rho=0.164, 0.112 respectively, P>0.05). (2) The birthweight showed significant correlations with placenta weight, placecnta volume and maternal BMI (Spearman rho=0.478, 0.361, 0.259 respectively, P<0.01). (3) The placenta weight at birth showed a significant correlation with placenta volume at birth (Spearman rho=0.467, P<0.01) and maternal BMI (Spearman rho=0.198, P<0.05). Regression analysis results: (1) Birth weight (g)=1136.9+1530.9×MOM+45.3×BMI-15.0×maternal age (r=0.29, P=0.01<0.05). (2) Placenta weight (g)=88.1+315.3×MOM+10.0×BMI+0.1×maternal age (r=0.27, P=0.02 <0.05). Conclusions The placental volume at 11-13+6 weeks of gestation has significant correlation with birthweight. This might assist in the identification of the high risk pregnancies caring large or low for gestational age fetuses.
6.Development and clinical application of screw remover for the skidded screws
Songlin TONG ; Jianjie XU ; Jianhao YU ; Yibin GAO ; Zhonghui LU ; Yijin WANG
Chinese Journal of Trauma 2012;28(2):132-135
ObjectiveTo develop an EZ screw remover for screwing out the skidded screws,discuss its design features and biomechanical characteristics and verify its extracting effect by clinical applications.MethodsFresh skeleton specimens were used in the study,including the femur (n =3),tibia ( n =3 ),radius and ulna ( n =3 ).The screws were fixed to the specimens according to clinical requirements and bone cement was filled into the medullary cavity.The specimens were randomized into three biomechanical test model groups,ie,Group A (measuring the skidded screws with the biggest torsion when the screws were taken out by screwdriver),Group B (measuring the skidded screws with the biggest torsion when the screws were taken out by one handle of EZ screw remover) and Group C ( measuring the skidded screws with the biggest torsion when the screws were taken out by two handles).The fixed screws were divided into two types of φ4.5 mm and φ3.5 mm.The experimental specimens were tested on the universal testing machines to measure the maximum torque,torsion angle,power consumption value and efficiency when drawing out the screws. The experimental data were compared between groups.The skidded screws encountered in clinical were taken out with EZ screw remover to verify the extracting effect.ResultsThe pullout torque in Groups A,B and C was 2.87-3.27 N · m,3.06-4.83N · m and 4.12-8.36 N · m respectively ( P < 0.05 ).The average torsion angle value in each corresponding group was 0.77°,0.28°,0.16° respectively (P < 0.05 ).When the screws were screwed out,the average power consumption was 21 J,32 J and 45 J in Groups A,B and C respectively and power ( mechanical efficiency) was 0.35 J/s,0.53 J/s and 0.75J/s in Groups A,B and C respectively,with significant differences ( P < 0.05 ).Seventeen pieces of the cannulated skidded screws of φ7.3 mm in seven patients were successfully taken out by using the EZ screw remover.ConclusionEZ screw removerhas enough resistance strength and rigidity to torsion as well as powerful clamping force and hence is an ideal tool for screwing out the skidded screw in orthopedics.
7.Relationship of athernsclerosis in carotid and lower limb arteries to coronary artery disease in type 2 diabetes
Dandan ZHANG ; Lichun AN ; Yiming MU ; Junhua MENG ; Bin DENG ; Xiaonan LI ; Zhonghui LI ; Jingtao DOU ; Juming LU ; Changyu PAN
Chinese Journal of Endocrinology and Metabolism 2009;25(4):366-369
s correlated with coronary disease. Examining these peripheral arteries, more efficient in combination, seems to be a helpful way for screening coronary disease.
8.Mental Health and Related Factors of Adolescent Students During Coronavirus Disease 2019 (COVID-19) Pandemic
Tian’ge LU ; Yao YU ; Zhonghui ZHAO ; Rongjuan GUO
Psychiatry Investigation 2022;19(1):16-28
Objective:
Adolescents are at a special stage of physical and mental development, which is a susceptible period for mental disorders. Since the outbreak of coronavirus pneumonia in December 2019, long term stress may have negative effects on the mental health of the adolescents. In the context of the coronavirus disease 2019 (COVID-19), the study was designed to investigate the mental and psychological health of adolescents in China and its possible related factors.
Methods:
A cross-sectional study design was adopted using a structured questionnaire which were distributed through the Internet to measure depression, anxiety, life events and stress related factors. Descriptive statistics and multiple regression analyses were conducted to process the data.
Results:
The final sample comprised 795 adolescents. The total detection rate of depression was 76.48% and the total detection rate of anxiety was 33.08%. ANOVA showed that there were significant differences in depression scores in terms of gender, anxiety scores, history of mental disorders, COVID-19 knowledge reserve, family and social contradictions (p<0.05). And there were significant differences in anxiety scores in terms of gender, depression scores, mental health knowledge reserves, family and social contradictions (p<0.05). Multiple regression analysis showed that anxiety score, health status and COVID-19 knowledge reserve were positively associated with depression score (p<0.01), and history of psychosocial disorders was negatively associated with depression score (p<0.05); depression score, family and social contradictions were significantly positively correlated with anxiety score (p<0.01), and history of mental disorders was significantly negatively correlated with SDS score (p<0.01).
Conclusion
During the outbreak of COVID-19, adolescent students with better understanding of the pandemic, more complete knowledge of mental health, and better family and social relationship had less impact on their mental health. Therefore, to ensure a sound social support system, elaborate health instruction, and family communication and mutual understanding are conducive to alleviating the psychological stress caused by the epidemic, and it is positive for adolescent students to maintain a good mental health.
9.Fetal discrepancy during first trimester in dichorionic twins
Yixiu ZHANG ; Hua MENG ; Yunshu OUYANG ; Yuxin JIANG ; Qing DAI ; Zhonghui XU ; Meng YANG ; Yan YUAN ; Jia LU ; Haiya LOU ; Peng LI ; Xiao YANG
Chinese Journal of Ultrasonography 2012;21(3):228-230
Objective To investigate the incidence and distribution of fetal discrepancy during the first trimester in dichorionic twins.Methods This was a prospective analysis of dichorionic twin pregnancies that underwent 11+0~ 13+6 week scan at a tertiary hospital from Sep 2008 to Oct 2010.Differences in crown-rump length (CRL),nuchal translucency ( NT),heart rate ( HR).deepest vertical pockets of amniotic fluid (DVP) for every pair of twin fetuses were calculated and expressed as absolute value and percentage of discordance.Results A total of 66 dichorionic twin pregnancies were included.The average CRL was significantly different between the larger fetus and the smaller one,which were (65.28 ±8.54)mm and (62.34 ± 8.49) mm respectively ( P < 0.001).The average NT was significantly different between two fetuses,which were ( 1.56 ± 0.35) mm and (1.28 ± 0.30) mm respectively. HR and DVP were also statistically different between two fetuses ( P <0.001).Conclusions The growth of two fetuses in normal dichorionic twins is not uniform during the first trimester.
10.Fetal akinesia deformation sequence: an etiology of fetal multiple joint contractures with poor prognosis
Liang WANG ; Hua MENG ; Yuxin JIANG ; Qing DAI ; Zhonghui XU ; Meng YANG ; Yan YUAN ; Yunshu OUYANG ; Yixiu ZHANG ; Jia LU ; Xiao YANG
Chinese Journal of Ultrasonography 2011;20(12):1063-1065
ObjectiveTo evaluate the diagnostic capability of prenatal ultrasound in diagnosis of fetal akinesia deformation sequence (FADS).MethodsThe prenatal sonographic characteristics of 5 fetuses with FADS were analyzed retrospectively.ResultsBoth multiple joint contractures and central nervous system (CNS) anomalies,which include 5 small head circumferences,2 short cerebellar diameters,and 1 flat forehead,were found by prenatal ultrasound in all 5 FADS fetuses.Additional fetal abnormalities such as micrognathia,polyhydramnios,short umbilical cord and intrauterine growth retardation were also observed.The results of fetal chromosome analysis were available in 2 cases indicating normal karyotype.Conclusions Prenatal identification and diagnosis of FADS is possible based on the findings of sonographic examination.