1.Effect of the ongoing time of applying Musk Xiaochuan paste in stable asthma
Dongsheng GAO ; Yajun ZHANG ; Youjun REN ; Guangyuan YANG ; Yan HUANG ; Liping ZHAO ; Zhonghao NAN
Chinese Journal of Biochemical Pharmaceutics 2016;36(4):108-110
Objective To explore the effect of the ongoing time of applying Musk Xiaochuan in the treatment of stable asthma and obtain the optimal therapy.Methods 129 cases of patients with stable asthma were randomly divided into 3h group (29 cases), 4h group (34 cases), 5h group (31 cases), 6h group (35 cases) according to the different applying time.The selection of points, applying frequency, treatment course remained the same, and then “dog day” was selected to apply Musk Xiaochuan paste for treatment.The asthma quality of life and asthma control pre-and post-treatment were observed.Results After applying, the asthma control questionnaire (ACQ) score difference value in 3h group was not preferable than the other groups, with no significant difference.The asthma quality life questionnaire (AQLQ) total score difference value in 4h group was significantly higher than the other 3 groups, with significant difference(P<0.05).The activity limitation score difference value and mental health difference value of AQLQ in 4h group were significantly higher than the other 3 groups, with significant difference(P <0.05), the asthma symptom score and stimulus response score difference values, health care for their own score difference value also showed significant effect (P<0.05).Conclusion The difference of the ongoing time of applying Musk Xiaochuan has different efficacy in the treatment of stable asthma, the efficacy of applying for 4h is better than 3, 5,6 h, while it could not determine the best time in asthma control.
2.Long-term clinical effect of full-mouth implant fixation in middle-aged and elderly patients with static computer-assisted implant surgery
Ziqiang CHEN ; Wenjuan ZHOU ; Jingyi REN ; Zhonghao LIU
Chinese Journal of Stomatology 2020;55(11):864-870
Objective:To evaluate long-term clinical outcome of implant-supported fixed prosthesis with the guidance of computer-aided design/computer-aided manufacturing (CAD/CAM) surgical template in old patients.Methods:Fifteen 50-67(58.6±5.3) year-old patients (11 males and 4 females) who received the digital implant surgery with the guidance of CAD/CAM surgical template and implant-supported fixed prosthesis in Department of Oral Implantology, Yantai Stomatological Hospital Affiliated to Binzhou Medical College from August, 2013 to Janurary, 2016 were included. There are 15 edentulous maxillas, 8 edentulous mandibles on which 145 implants were placed in total. After the placement of implant, the accuracy of CAD/CAM surgical template was assessed by comparing the post-operative 3-dimensional location of implant with the pre-operative design. The 5-year survival rate of implant and prosthesis was recorded, and marginal bone loss around implants and the development of complication were evaluated by radiological and clinical examination respectively.Results:The result on accuracy of CAD/CAM surgical template showed that deviations in neck and apex of implants were (0.78±0.59) and (1.38±0.63) mm respectively, depth deviation was (0.65±0.35) mm and angle deviation was 4.12°±2.77°. The 5-year cumulative survival rate of implants was 98.6%(143/145). In all 145 implants, the prevalence of implant-related biological complication was 4.1%(6/145). The prosthesis-related mechanical complication rate was 57%(13/23). After 5-year function, mean peri-implant bone loss was (0.69±0.35) mm.Conclusions:This 5-year follow-up retrospective study showed that implant-supported fixed prosthesis with the guidance of CAD/CAM surgical template in middle aged and elderly patients could achieve good long-term clinical outcome and patient satisfaction.
3.Study on the effect of personal radiological protective equipment used in diagnostic radiology
Qiang FU ; Lu WANG ; Yue XI ; Liang SUN ; Shengrong JI ; Zhonghao REN ; Jia WANG ; Bing LIU
Chinese Journal of Radiological Medicine and Protection 2023;43(6):462-468
Objective:To study the actual effect of the use of personal protective equipment of the examined individuals, and provide reference and basis for the correct use of personal protective equipment and the radiological health administrative law enforcement.Methods:From February to June 2022, the imaging department of Qingdao Municipal Hospital selected 170 patients who underwent X-ray imaging examination (oral panoramic, dental radiography, DR photography, CT scanning), including 25 with oral panoramic and dental radiography, 60 with CT scanning and 60 with DR imaging. The thermoluminescent dosimeter was used to detect the ambient dose equivalent at the point of concern for 170 examined individuals who have used personal protective equipment to cover their sensitive parts, and to analyze the data detected at the same point as above when routinely using the same equipment.Results:There was a statistically significant difference in the dose equivalent at the same points inside and outside the lead neckband ( t=-2.23, P<0.05). There was no statistically significant difference in the dose equivalent at the same point inside and outside the lead collar during dental radiography ( P>0.05). During DR photography (chest PA, lateral and lumbar AP), the examined individuals were wearing lead aprons. Among them, there was a statistically significant difference in the dose equivalent at the same points inside and outside the lead aprons of children′s chest PA and adults′ chest PA ( U=10.00, 19.00, P<0.05). There was no statistically significant difference in the dose equivalent at the same points inside and outside the lead aprons of adult′s chest PA and lumbar AP ( P>0.05). When performing CT scan (chest or upper abdomen), there was a statistically significant difference in the dose equivalent at the same points of wrapped lead aprons( U=878.50, 11.00, P<0.05). Conclusions:The correct use of personal protective equipment is a complex technical problem. It is very important to fully and accurately understand the optimization principle of radiation protection and correctly use personal protective equipment for the examined individuals. The administrative punishment of radiation health on the use of personal protective equipment of the examined individuals should be cautious.
4.LncRNA-m18as1 competitively binds with miR-18a-5p to regulate follicle-stimulating hormone secretion through the Smad2/3 pathway in rat primary pituitary cells.
Weidi ZHANG ; Wenzhi REN ; Dongxu HAN ; Guokun ZHAO ; Haoqi WANG ; Haixiang GUO ; Yi ZHENG ; Zhonghao JI ; Wei GAO ; Bao YUAN
Journal of Zhejiang University. Science. B 2022;23(6):502-514
Long noncoding RNAs (lncRNAs) are expressed in different species and different tissues, and perform different functions, but little is known about their involvement in the synthesis or secretion of follicle-stimulating hormone (FSH). In general, we have revealed lncRNA‒microRNA (miRNA)‒messenger RNA (mRNA) interactions that may play important roles in rat primary pituitary cells. In this study, a new lncRNA was identified for the first time. First, we analyzed the gene expression of lncRNA-m18as1 in different tissues and different stages by reverse transcription-quantitative polymerase chain reaction (RT-qPCR) and observed the localization of lncRNA-m18as1 with fluorescence in situ hybridization, which indicated that this lncRNA was distributed mainly in the cytoplasm. Next, we used RT-qPCR and enzyme-linked immunosorbent assay (ELISA) to analyze the regulation of FSH synthesis and secretion after overexpression or knockdown of lncRNA-m18as1 and found that lncRNA-m18as1 was positively correlated with FSH synthesis and secretion. In addition, mothers against decapentaplegic homolog 2 (Smad2) was highly expressed in our sequencing results. We also screened miR-18a-5p from our sequencing results as a miRNA that may bind to lncRNA-m18as1 and Smad2. We used RNA immunoprecipitation-qPCR (RIP-qPCR) and/or dual luciferase assays to confirm that lncRNA-m18as1 interacted with miR-18a-5p and miR-18a-5p interacted with Smad2. Fluorescence in situ hybridization (FISH) showed that lncRNA-m18as1 and miR-18a-5p were localized mainly in the cytoplasm. Finally, we determined the relationship among lncRNA-m18as1, miR-18a-5p, and the Smad2/3 pathway. Overall, we found that lncRNA-m18as1 acts as a molecular sponge of miR-18a-5p to regulate the synthesis and secretion of FSH through the Smad2/3 pathway.
Animals
;
Cell Line, Tumor
;
Cell Proliferation
;
Follicle Stimulating Hormone/metabolism*
;
Gene Expression Regulation, Neoplastic
;
In Situ Hybridization, Fluorescence
;
MicroRNAs/metabolism*
;
RNA, Long Noncoding/metabolism*
;
Rats