1.The effect of the bedside protection against different operators in percutaneous coronary intervention
Zhiting WANG ; Guoquan CAO ; Miao MIAO ; Weijian HUANG ; Zhouqing HUANG
Chinese Journal of Radiological Medicine and Protection 2015;35(9):709-712
Objective To discuss the effect of the bedside shielding protection on the first and second operators against position radiation in percutaneous coronary intervention.Methods The surface entrance dosage rate for the first and second operators at 125 cm height with and without radiation protection shielding (provided separately) were measured.The t-test was used for statistical analysis of arithmetic mean values of dosage rates.And the effect of bedside shielding protection was calculated.Results The position radiation dosage rate at which the first operator exposed was significantly higher than that for the second in the case of no bedside protection (t =97.1-2 263.0,P < 0.05),whereas the dosage rate at which the first operator (except for the left foot position) exposed was significantly lower than that for the second in the case of no bedside protection (t =-80.9-275.1,P < 0.05).The shielding effect of bedside protection on the first and second operators was in the range of 92.26%-99.36% and 27.83%-97.90%,respectively.Conclusions The bedside protection may effectively reduce position radiation dose to patients and the use of bedside protection changed the trends in the dose distribution in operators' standing region.Attention should be focused on the radiation protection of the second operators in daily work by making full use of bedside protection.
2.Mechanism of a cardiovascular automatic feedback control instrument and animal experiments
Zhiting WU ; Yuzhi GE ; Guotai SHENG ; Pingliang CAO ; Xiaobing LIU ; Yanyang LIU ; Junxi CHEN ;
Chinese Journal of Emergency Medicine 2006;0(10):-
Objective To design and develop a cardiovascular automatic feedback control instrument for rescuing the critical patients.Methods Ten dogs used this kind instrument and the effects were obserred.Resuts The experiment of the dogs showed:the computer collected samples promptly,accurately and rapidly,and the instrument could help us to reach the expected goal.Conclusion In animal experiments,it showed that the whole cycle,from obtaining blood pressure to adjusting the amounts of medicine through feedback,was shortened.The calculating was accuratel and curative effect was reliable.This instrument is wait to be apprnsed by clinic.
3.The influence of different ceiling-mounted shield positions on operators' radiation dose in percutaneous coronary intervention
Zhiting WANG ; Xiang ZHENG ; Hong YE ; Caiyun WEN ; Weijian HUANG ; Guoquan CAO
Chinese Journal of Radiological Medicine and Protection 2017;37(12):946-949
Objective To discuss the influence of the change in ceiling-mounted shield positions on the radiation doses to the first and second operators during percutaneous coronary intervention.Methods In this study,the entrance surface dose (ESD) rates were measured for the first and second operators at 125 cm and 155 cm height on different ceiling-mounted shield positions separately through transradial approach.Measurements were repeated 20 times for each position and T test was used for statistical analysis of dose rate arithmetic mean values.Results For the first operator,the effective dose values were obtained only on left foot position.The ESD rate values at ceiling-mounted shield position close to patient were higher than that close to operators (t125 =46.9,t155 =4.1,P <0.05).For the second operator,the ESD rate values on his foot position,right foot position,left anterior oblique position and right anterior oblique position at ceiling-mounted shield position close to the operator,were higher than that close to the patient separately (t125 =11.9,24.4,11.2,2.7,t155 =16.1,2.8,14.4,28.8,P < 0.05).The ESD rate values on head position,left foot position,left head position at ceiling-mounted shield position close to the operator,were lower than that close to the patient (t125 =-4.3,-2.4,-80.4,t155 =-10.2,-6.7,-152.6,P < 0.05).Conclusions The change in the ceiling-mounted shield positions gave rise to change in radiation dose to the operators.The changes in radiation doses caused by the changes in ceiling-mounted shield positions are different in various angiographic positions.Ceiling-mounted shield should be used in a reasonable way in agreement with different positions in percutaneous coronary intervention so as to effectively reduce operators radiation dose.
4.Research on mode of anisotropy and other diffusion tensor imaging derived indices of white matter with mild to moderate Alzheimer disease based on tract based spatial statistics
Caiyun WEN ; Xiaojun ZHOU ; Suyuan WANG ; Meihao WANG ; Zhen WANG ; Guoquan CAO ; Zhiting WANG
Chinese Journal of Radiology 2019;53(2):138-144
Objective We performed a diffusion tensor imaging (DTI) study to explore the value of mode of anisotropy (MO) and other DTI-derived indices in assessing white matter fiber damage with mild to moderate Alzheimer disease (AD) patients. Methods This study was a prospective study. From February 2015 to February 2018, 33 patients with mild to moderate AD according to criteria were prospectively recruited as AD group at the First Affiliated Hospital of Wenzhou Medical University. Twenty healthy age-, sex-matched volunteers were recruited as normoal conctrast (NC) group. All subjects were performed by conventional brain MRI and DTI scans. The MO, anisotropic fraction (FA), mean diffusivity (MD), radial diffusivity (RD) and axial diffusivity (AxD) of white matter fibers were obtained from DTI images after TBSS post-processing. The statistical analyses of DTI indices between AD group and NC group were carried out in Functional MRI Software Library software. Results As compared with NC group, we found 1 cluster with significant decrease FA and increase RD in AD group, the affected fibers involving bilateral anterior thalamic radiation, corticospinal tract, cingulate gyrus, hippocampus, inferior fronto-occipital fasciculus, inferior longitudinal fasciculus, uncinated fasciculus, superior longitudinal fasciculus (P<0.05). The MD value increase(P<0.1) was found to coincide with the decrease of FA and the increase of RD, while no significant increase or decrease in P<0.05. Three clusters of MO increases (P<0.05) accompanying with increases of AxD were found in left anterior limb of internal capsule, bilateral posterior limb of internal capsule, posterior forceps, left centrum semiovale and parietal lobe. Two clusters of MO decreases (P<0.05) accompanying with decreases of FA and increases of RD were found in fornix, forceps, external capsule, centrum semiovale and left frontal lobe. Conclusions The combination of MO with DTI routine tensor indices (FA, RD, MD, AxD) can further reveal the microstructural damage of white matter fibers in AD, especially to crossing-fibers. The abnormalities of MO combined with FA, RD and MD reveal the degeneration of both bundles of crossing-fibers,and the abnormalities of MO combined with AxD reveal that the white matter damage was mainly caused by axon damage of one bundle of cross fibers.
5.Analysis of plague monitoring results from 2018 to 2020 in Guizhou Province
Xiaojun GONG ; Hongwu HUANG ; Ying TAO ; Bing CAO ; Qing LU ; Zhiting ZOU
Chinese Journal of Endemiology 2021;40(12):979-982
Objective:To analyze the monitoring results of plague foci in Guizhou Province, to master the epidemic dynamics of the plague and to formulate the prevention and control measures.Methods:The plague monitoring data from 2018 to 2020 in Guizhou Province were collected from China Disease Prevention and Control Information System Plague Prevention and Control Information Management System to analyze the plague epidemic situation. The murine animals capture methods used were cage clip method, 5 m cage clip method and day-by-day rodent capture method. Bacterial culture and hemagglutination were used in laboratory.Results:A total of 2 273 murine animals were captured indoors with cage clip method, and the Rattus norvegicus was the dominant species, accounting for 47.29% (1 075/2 273), Rattus flavipectus and Mus musculus were common species, accounting for 43.55% (990/2 273) and 5.10% (116/2 273). A total of 1 460 murine animals were captured outdoors with 5 m cage clip method, and the Rattus rattus sladoni was the dominant species, accounting for 35.48% (518/1 460), Rattus flavipectus and Eothenomys miletus were common species, accounting for 16.03% (234/1 460) and 8.70% (127/1 460). A total of 5 742 murine animals (including 3 733 animals captured with cage clip method and 5 m cage clip method, 2 009 animals captured with day-by-day rodent capture method) were examined and 1 176 with flea, the flea infestation rate of murine animals was 20.48%, Xenopsylla cheopi was the dominant flea species [56.63% (3 020/5 333)] and the index was 0.53. Laboratory test results were all negative. Conclusions:The plague foci of Guizhou Province is at a quiescent stage, but the reignition cannot be ruled out. The monitoring of plague should be strengthened, the quality of the monitoring should be improved, and health education and publicity should be carried out to prevent the occurrence of human plague outbreaks.
6.Study on the clinical application of pre-breathing mode in double-low imaging of 320-slices CT for pulmonary artery
Xiaofei LI ; Qingting QIN ; Yurong LIAO ; Lizhuan YANG ; Peng YANG ; Weinan LIN ; Changyuan XIAN ; Chenxi ZENG ; Zhiting CAO
China Medical Equipment 2024;21(1):59-62
Objective:To explore the clinical application value of pre-breathing mode in double-low imaging of 320-slices computed tomography(CT)for pulmonary artery.Methods:A total of 100 patients who underwent CT pulmonary angiography(CTPA)for suspected pulmonary embolism(PE)in Liuzhou People's Hospital from July 2021 to September 2022 were prospectively selected as the research subjects and they were randomly divided into observation group and control group,with 50 cases in each group.The patients of the control group adopted conventional breathing mode(the breathing password was activated after reaching the threshold,and the scan was triggered after 6 s),while the patients of the observation group adopted the pre-breathing mode(the breathing password was activated after 1 or 2 seconds,and the scan was triggered after reaching the threshold).Both two groups adopted double low-technique scan of 320 slices CT.The differences in delay time,radiation dose,the points of subjective and objective image quality,and other indicators were compared between the two groups.Results:The volume CT dose index(CTDIvol),dose length product(DLP),effective dose(ED)and delay time of the observation group were significantly lower than those of the control group(t=76.230,30.225,12.282,7.088,P<0.05),respectively.The comparison of the subjective points of image qualities between the two groups indicated that there were 25 cases with 5 points,23 cases with 4 points and 2 cases with 3 points in the observation group,and there were 21 cases with 5 points,26 cases with 4 points and 3 cases with 3 points in the control group.There was no significant difference in the averagely subjective points of image qualities between two groups(P>0.05).The signal-to-noise ratio(SNR)and signal to noise ratio(CNR)of the observation group were significantly lower than those of the control group,and the noise level(SD)of the observation group was significantly higher than that of the control group(t=25.441,23.886、11.426,P<0.05),respectively.The CT values of the artery trunk of right pulmonary,artery branch of right pulmonary,artery trunk of left pulmonary and artery branch of left pulmonary in the observation group were significantly higher than those in the control group(t=2.256,2.225,2.042,2.277,P<0.05),respectively.Conclusion:The pre-breathing mode can effectively improve CTPA image quality,and reduce radiation dose and the dosage of contrast agent,which clinical application effect is significant.It is worth learning.