1.Research and Design of Calibration Device for Medical Test Lung.
Tingting ZHANG ; Qiu HUANG ; Xuhui LIAO ; Chenggang HUANG ; Zhilong RUAN ; Yafei YANG ; Tao LIN ; Bo YANG
Chinese Journal of Medical Instrumentation 2023;47(5):528-532
In order to solve the problems of quality control and traceability of medical test lung for meeting the calibration conditions of JJF 1234-2018 Calibration Specification for Ventilators, the calibration device and method are researched for compliance and airway resistance of medical test lung in this paper. A calibration device for medical test lung is designed using constant volume active piston technology to simulate human breathing. Through comparison experiment, the deviation between this device and the similar foreign device can be found. The deviation is lower than 0.4% for lung compliance and lower than 0.7% for airway resistance. The calibration of lung compliance and airway resistance can be completed by this device. This device has a clear and complete traceability path to ensure quality control from the source. The calibration of ventilator is improved. This paper provides a reference for related metrology departments and medical institutions to study on quality inspection of respiratory medical instruments.
Humans
;
Calibration
;
Ventilators, Mechanical
;
Respiration
;
Quality Control
;
Lung
2.Epidural Labor Analgesia: Comfort and Safety Run in Parallel, with Teaching and Quality Control Complementing Each Other
Yu ZHANG ; Mengyun ZHAO ; Lijian PEI ; Yahong GONG ; Xia RUAN ; Yuguan ZHANG ; Di XIA ; Zhilong LU ; Zhanjie ZHANG ; Jiong ZHOU ; Chenwei FU ; Jinsong GAO ; Yuguang HUANG
Medical Journal of Peking Union Medical College Hospital 2024;15(2):246-250
Epidural labor analgesia aims to provide effective medical services to alleviate labor pain in parturients, while adhering to the principles of voluntary participation and clinical safety. In 2018, Peking Union Medical College Hospital(PUMCH)became one of the first pilot units for labor analgesia in China, and has achieved satisfactory results in high-quality development of labor analgesia. This article mainly introduces the achievements and experience of labor analgesia at PUMCH, including: (1) prioritizing maternal and infant safety, arranging personnel rationally, and developing standardized treatment processes through multidisciplinary collaboration to ensure safe and comfortable childbirth; (2) leveraging the hospital's comprehensive capabilities in emergency treatment, and improving collaborative rescue plans for critically ill parturients and newborns; (3) implementing advanced teaching methods to effectively train and conduct simulated drills for labor analgesia and rescue of critically ill parturients; (4) conducting patient education and informative lectures to help parturients acquire a scientific understanding of labor analgesia. We hope that this experience can provide reference and inspiration for other hospitals.