1.Application value of low dose CT scanning in lung puncture biopsy
Chinese Journal of Primary Medicine and Pharmacy 2015;(8):1163-1165
Objective To observe the application of low dose CT scanning in lung puncture biopsy,and to discuss the feasibility and limitations.Methods 100 cases of CT guided percutaneous lung biopsy,used SPSS soft-ware to generate random numbers,odd number into the routine dose group,even number into low doses study group. The routine dose group of 50 patients underwent routine dose CT scanning(200mA,reconstruction thickness 2.0mm, pitch 16mm/rot)and puncture,and the low doses study group were given low dose CT scanning in 50 patients (10mA,reconstruction thickness 2.0mm,pitch 23mm/rot)and puncture.Two groups after routine disinfection punc-ture,were taken tissue samples for pathological examination.The two groups of CT scanning dose and image quality, the success rate of puncture and complications were compared.Results The success rate of puncture in conventional dose scan group was 90.00%;CT dose index weighted index CTDIw was (23.64 ±5.91)mGy;the average dose length product DLP was (172.31 ±43.08)mgy ×cm.The success rate of puncture of the low doses study group was 84.00%;CTDIw was (1.22 ±0.31)mgy;DLP was (8.56 ±2.14)mgy ×cm.The successful puncture rate of the two groups had no significant difference(χ2 =0.638 9,P=0.374 2);The radiation dose was statistically significant(CTDIw compare:t=2.798 3,P=0.005 4;DLP compare:t=2.684 9,P=0.007 8);The image quality can meet the need of puncture biopsy;At the same time,the two groups had no severe complications.Conclusion Low dose than routine dose CT scanning in lung biopsy success rate has no difference,but which can significantly reduce the radiation dose.
2.Progression of Breviscapine Protecting Hepatic Ischemia-Reperfusion Injury
Chinese Journal of Bases and Clinics in General Surgery 2008;0(09):-
Objective To report the progression of breviscapine's protective effect to hepatic ischemia-reperfusion injury.Methods Pertinent literatures and journal articles published in recent years were reviewed,and the progression of breviscapine protecting hepatic ischemia-reperfusion injury in the experimental and clinical research were analyzed and summarized.Results The role of breviscapine is considerable extensive.It can protect hepatic ischemia-reperfusion injury by anti-oxyradical and anti-lipid peroxidation,inhibiting mitochondrial damage,intracellular calcium overload,intra-thromboxane and apoptosis,improving microcirculation,and so on.Conclusion Breviscapine plays a protective role in hepatic ischemia-reperfusion injury,and it will be of great value to application and research.
3.ERp in medical disposable materials management
Chinese Journal of Hospital Administration 2012;28(3):229-231
Combined with the development requirements of hospital medical disposable materials management and hospital information management,introduced a novel medical disposable materials management pattern which base on the enterprise resource planning chain supply systems.By optimizing purchasing procedure,inventory management,precision financial management,to realize the integrated management of the medical consumable materials affairs and financial affairs.
4.Cumulative radiation dose of multiple trauma patients during their hospitalization
Zhikang WANG ; Jianzhong SUN ; Zudan ZHAO
Chinese Journal of Radiological Medicine and Protection 2012;32(3):323-325
Objective To study the cumulative radiation dose of multiple trauma patients during their hospitalization and to analyze the dose influece factors.Methods The DLP for CT and DR were retrospectively collected from the patients during June,2009 and April,2011 at a university affiliated hospital.The cumulative radiation doses were calculated by summing typical effective doses of the anatomic regions scanned.Results The cumulative radiation doses of 113 patients were collected.The maximum,minimum and the mean values of cumulative effective doses were 153.3,16.48 mSv and(52.3 ± 26.6) mSv.Conclusions Multiple trauma patients have high cumulative radiation exposure.Therefore,the management of cumulative radiation doses should be enhanced.To establish the individualized radiation exposure archives will be helpful for the clinicians and technicians to make decision wheather to image again and how to select the imaging parameters.
5.Applications of CR in the Fever Outpatient Department
Jianming HUA ; Weimin ZHANG ; Zhikang WANG
Journal of Practical Radiology 2001;0(08):-
Objective To evaluate the equipment scheme and value of computed radiography (CR) in the fever outpatient department.Methods One scanner of two sets of CR system was placed to the fever outpatient department for obtaining digital images. Those images and relative clinical data were transited to department of radiology by radiological information system (RIS). Then radiologists finished the diagnostic reports and ordered the printer in the fever outpatient department to print after a necessary post-process and analysis for obtained images.Results (1) Only one radiological technician was need to work in the fever outpatient department; (2) The images could preview in 55 seconds and received chest X-ray report in 15 ~ 30 minutes after exposure.Conclusion This project adapts to routine chest X-ray of patients in the fever outpatient department because of preventing contagion and high efficiency.
6.The Comparative Study of Imaging Characteristics Between "Wet"and "Dry"Laser Film
Zhikang WANG ; Liyong JIE ; Weimin ZHANG
Journal of Practical Radiology 2001;0(09):-
Objective By estimation and analysis of imaging characteristics of "dry"and "wet" laser print to appreciate the imaging quality of two different printing ways and its advantages and disadvantages respectively.Methods ①28 routine MRI and 28 routine CT images were selected,the imaging quality of MR and CT images including brightness,contrast,detail display,diagnostic performance and general impression were evaluated by 6 radiologists;②CT and MR images of skull,lumbus,knee and hand joint adjusted to the best states, then printed by "dry" and "wet" laser printer;③The sensitive characteristic curve both "dry" and "wet" printing were made with opital densimeter,SMPTE card,then an objective evaluation of stabilization was done.Results ①The imaging quality for the dry imaging possess in 56 cases,the much worse was 0.3%,the best was none,the slightly worse,medial and slightly better was 31.9%,58.9% and 8.9% respectively;②The maximum density of the dry film and the wet film was 3.34 and 3.62 respectively,the dynamic range of the latter was more wide than that of former;③The wet films exposed to temperatures from 40℃ to 100℃,did not show a noticeable alteration in optical density,but the dry film showed gray scale degradation at temperatures above 70℃.Conclusion In imaging quality,stability of film,brightness and contrast of film,"wet" laser film is better than that of "dry" laser film,but "dry"laser film has still good diagnostic function that can be used in clinical diagnosis.
7.Application of Latitude Reduction Technique in CR Foot Radiography
Jianming HUA ; Zhikang WANG ; Weimin ZHANG
Journal of Practical Radiology 2001;0(01):-
Objective To evaluate the application of latitude reduction technique in CR image processing based on different tissuethickness of foot radiography.Methods The images of adult foot radiography in 50 cases were analysed retrospectively.Latitude reduction technique was used in comparison with routine CR image processing,in order to display different tissue position definition such as soft tissue in phalanges of toes,thumb nail groove,the distal of fifth phalanges,talus bone trabecula and calcaneocuboidal joint space.Results CR image processed by latitude reduction technique could showe clearly tissue and structure of foot and was super than that of routine CR image processing.(t=7.732,P
8.Detections of the Focal Regions Temperature for High Intensity Focused Ultrasound.
Jiaping DING ; Jucheng ZHANG ; Zhikang WANG
Chinese Journal of Medical Instrumentation 2015;39(2):118-121
As a tumor thermal ablation technology in cancer therapy, HIFU (High Intensity Focused Ultrasound) has been developed rapidly in recent years. With the technology becoming more and more mature, it's clinical application is becoming more and more widely. In HIFU therapy, the high-intensity ultrasound energy is focused in the target tumor tissue, generating heat within very short time, causing coagulation necrosis, so that the effect of the treatment is achieved. To ensure safe and therapeutic efficacy, HIFU therapy needs to be properly monitored by medical imaging, and temperature in the target has to be precisely measured, this article is based on the current domestic and foreign detection methods of the focal region temperature.
Diagnostic Imaging
;
High-Intensity Focused Ultrasound Ablation
;
Humans
;
Neoplasms
;
therapy
;
Temperature
;
Ultrasonic Therapy
9.Effect of finasteride on reducing hemorrhage in holmium lasterenucleation of prostate
Meng GU ; Qi CHEN ; Yanbo CHEN ; Zhong WANG ; Zhikang CAI
Chinese Journal of Geriatrics 2014;33(3):264-266
Objective To evaluate the effect of preoperative oral finasteride on patients with benign prostate hyperplasia (BPH) undergoing holmium lasterenucleation of prostate (HoLEP).Methods A total of 156 BPH patients from Department of Urology in Shanghai Ninth People's Hospital from Sep.2010 to Mar.2012 was analyzed retrospectively.79 patients receiving oral 5 mg/d finasteride before operation were selected as medication group,and the 77 patients without taking finasteride were selected as control group.The perioperative data,including operation time,amount of washing fluid during operation,preoperative and postoperative changes of hemoglobin level and postoperative bladder washing time were compared between two groups.Results Compared with control group,the changes of hemoglobin level after HoLEP,amount of washing fluid during operation,and postoperative bladder washing time with normal saline were significantly decreased in experimental group[(1.08±0.27) g/L vs.(1.55±0.32) g/L,(27.51±3.67) L vs.(36.89±6.47) L,(24.85±4.17) h vs.(35.87±5.10) h,all P<0.05].Conclusions Oral finasteride before HoLEP can reduce perioperative bleeding and the volume of bladder irrigation with normal saline.
10.The research of optimizing exposure factors in digital chest radiography
Jianzhong SUN ; Zhikang WANG ; Weimin ZHANG ; Jinsong CAI
Chinese Journal of Radiology 2010;44(10):1069-1072
Objective To explore the optimum exposure factors in digital chest radiography.Methods Chest phantom was exposed under auto exposure control model with 73, 90, 125kV and S200,400,800 plus or minor 4 micro-adjust for each sensitivity grade. Meanwhile dose area product (DAP) was recorded and the value of IQFinv was analyzed automatically by Artinis CDRAD Analyzer 1.1. Ten volunteers were exposed with 73 kV, S800 - 2; 90 kV, S800 + 2 and 125 kV, S400 + 2. Two radiologists evaluated and scored image quality. Statistical analysis was performed using one way ANOVA test by SPSS 12. 0. Results ( 1 ) The quality scores of volunteers' images obtained with three combinations of exposure factors were 2. 7 ± 0. 5 for 73 kV group, 2. 9 ± 0. 3 for 90 kV group and 2. 8 ± 0. 4 for 125 kV group. The difference among them was not statistically significant ( F = 0. 587, P > 0. 05 ). Whereas the DAP values were (29. 1 ± 7.9) mGy · cm2 for 73 kV group, ( 30. 5 ± 4. 5 ) mGy ·cm2 for 90 kV group and (40. 4 ±7.6) mGy · cm2 for 125 kV group, with statistically significant difference among them ( F = 9. 803, P <0. 01 ). (2) In all three kV conditions, DAP value of phantom declined when sensitivity increased. There was a difference of DAP value by 11% between two successive sensitivity grades. Under the condition of same sensitivity, DAP value changed with kV in the following order: 73 kV >90 kV > 125 kV. (3) The value of IQFinv decreased when sensitivity increased. Under the condition of same sensitivity, IQFinv changed with kV as follow: 73 kV >90 kV > 125 kV. Conclusion The combination of exposure factors of 90 kV and S800 + 2-S800 +4 is optimum for digital chest radiography.