1.Portal veinous hemodynamics after subtotal splenectomy and portaazygous devascularization
Jingshan HUO ; Jisheng CHEN ; Zhuo WU ; Rufu CHEN ; Zhihao ZHUANG ; Qingjia OU
Chinese Journal of General Surgery 2010;25(1):20-23
Objective To evaluate perioperative portal hemodynamic alterations in cirrhotic patients undergoing subtotal splenectomy,podicled spleen remnant retroperitoneal transplantation plus lower esophagus transection in the treatment of portal hypertension.Method Forty patients with cirrhotic portal hypertension were randomly allocated into 2 groups:splenic transplantation group (n = 20),in which patients underwent subtotal splenectomy with pedicled remnant spleen retroperitoneal transplantation and cardia-esophageal devascularization and transection,and control group (n = 20),in which splenectomy and cardia-esophageal devascularization and transection were performed.The cross section area,blood velocity and flow and collateral circulation of portal parameters were comparatively evaluated by 3D DEC MRA,and the size of remnant spleen,blood flow and collateral circulation of retroperitoneal transplanted spleen were comparatively assessed.Results At 6-month after operation,the disappearance of esophageal-gastric varices in two groups was similar,and the cross section areas of main portal vein (MPV) in two groups all decreased postoperatively,in study group it was (1.81±0.73) cm~2 vs.(1.20±0.52) cm~2,P < 0.01;in control group it was (1.78±0.52) cm~2 vs.(1.30±0.12) cm~2,p <0.01.The mean blood velocity of MPV decreased postoperatively,in study group it was (9.86±0.10) cm/s vs.(7.06±1.92) cm/s,P <0.01;In control group it was (10.0 ±0.6)cm/s vs.(8.2±2.4) cm/s,P <0.01.The mean blood flow velocity of MPV in study group was lower postoperatively than that in control group(P<0.01).The mean blood flow volume of MPV decreased postoperatively from (15.0±1.9) ml/s to (10.5 ±2.7)ml/s,P <0.01 in study group;and from (14.9±2.1) ml/s to (11.6±2.1) ml/s,P < 0.01 in control group.The mean blood flow volume of MPV in study group was lower postoperatively than that in control group(P<0.05).A significant collateral formation was observed around the retroperitoneally translocated pedicled remnant spleen.Conclusions Compared with splenectomy,subtotal splenectomy,retroperitoneal translocation of the pedicled remnant speen helps to preserve splenic function as well as to increase retroperitoneal collateral formation which is conducive to further decreasing the portal veinous pressure.
2.PSO+: nonlinear fitting fluorescence data based on particle swarm optimizing combine with other iteration algorithm.
Da FU ; Youbing CHEN ; Zhihao ZHUO ; Xiaoping MIN ; Hai WANG ; Shengxiang GE ; Shiyin ZHANG ; Jin WANG
Journal of Biomedical Engineering 2019;36(3):414-420
The convective polymerase chain reaction (CCPCR) uses the principle of thermal convection to allow the reagent to flow in the test tube and achieve the purpose of amplification by the temperature difference between the upper and lower portions of the test tube. In order to detect the amplification effect in real time, we added a fluorophore to the reagent system to reflect the amplification in real time through the intensity of fluorescence. The experimental results show that the fluorescence curve conforms to the S-type trend of the amplification curve, but there is a certain jitter condition due to the instability of the thermal convection, which is not conducive to the calculation of the cycle threshold (CT value). In order to solve this problem, this paper uses the dynamic method, using the double S-type function model to fit the curve, so that the fluorescence curve is smooth and the initial concentration of the nucleic acid can be deduced better to achieve the quantitative purpose based on the curve. At the same time, the PSO+ algorithm is used to solve the double s-type function parameters, that is, particle swarm optimization (PSO) algorithm combined with Levenberg-Marquardt, Newton-CG and other algorithms for curve fitting. The proposed method effectively overcoms PSO randomness and the shortcoming of traditional algorithms such as Levenberg-Marquardt and Newton-CG which are easy to fall into the local optimal solution. The of the data fitting result can reach 0.999 8. This study is of guiding significance for the future quantitative detection of real-time fluorescent heat convection amplification.
Algorithms
;
Fluorescence
;
Fluorescent Dyes
;
Polymerase Chain Reaction