1.Effects of anterolateral femoral perforator flaps pedicled with oblique branch of lateral circumflex femoral artery and carrying fascia lata in repairing destructive wounds and rebuilding function of hands or feet
Chengwei GE ; Guodong JIANG ; Junnan CHENG ; Liping GUO ; Zhigang CHE ; Song YUAN ; Jihui JU
Chinese Journal of Burns 2024;40(9):842-848
Objective:To investigate the effects of anterolateral femoral perforator flaps pedicled with oblique branch of lateral circumflex femoral artery and carrying fascia lata in repairing destructive wounds and rebuilding function of hands or feet.Methods:This study was a retrospective observational study. From January 2022 to March 2023, 16 patients with destructive wounds in hands or feet combined with extensor tendon defects who met the inclusion criteria were admitted to Suzhou Ruihua Orthopedic Hospital, including 12 males and 4 females, aged 3 to 63 years. The wounds were located on the hands in 12 cases and on the feet in 4 cases. The number of defective extensor tendon ranged one to five, and the length of the defect ranged from 2.5 to 6.0 cm. The wound area was 11.0 cm×5.5 cm to 29.0 cm×9.5 cm after debridement. The wounds were repaired with anterolateral femoral perforator flaps pedicled with oblique branch of lateral circumflex femoral artery and carrying fascia lata, and the flap area was 12.0 cm×6.5 cm to 30.0 cm×11.0 cm. The fascia lata was used to repair the extensor tendon defects, and the harvesting area of fascia lata was 8.0 cm×3.0 cm to 12.0 cm×8.0 cm. The wounds in flap donor areas in 15 patients were sutured directly, and the wound in flap donor area in 1 patient was covered with medium-thickness skin graft from lower abdomen. The survival of flaps and the wound healing in donor and recipient areas of flaps were observed within 1 week after operation. The number of patients who underwent thinning and plastic surgery or tenolysis was recorded during postoperative follow-up. At the last follow-up, the recovery of sensory function of the transplanted flaps on hands or feet was evaluated, the efficacy of flap repair was evaluated according to the comprehensive flap evaluation scale, and the function of hands was evaluated according to the trial standards for evaluation of partial function of upper extremity by the Hand Surgery Society of Chinese Medical Association. The following two indexes were compared, including the measured total active motion of the injured fingers and the foot function assessed using Maryland foot function scale between before surgery and at the last follow-up.Results:Arterial crisis occurred in flaps in 2 patients after operation, and the flaps survived after timely exploration; the flaps in the rest patients survived well after operation. No obvious scar hyperplasia or ulceration was observed in donor and recipient areas of flaps after operation. All patients were followed up for 8 to 16 months, of which 6 patients underwent flap thinning and plastic surgery 6 to 7 months after operation, and 4 patients underwent tenolysis 3 to 6 months after operation. At the last follow-up, the recovery of sensory function of flaps reached S1 level in 5 cases and S2 level in 11 cases, and the two-point discrimination only had 1 point. The efficacy of flap repair scored 80 to 91, which were evaluated as excellent in 5 cases, good in 9 cases, and acceptable in 2 cases. The hand function was evaluated as excellent in 5 cases, good in 5 cases, and acceptable in 2 cases. The active extension function of the injured finger/toe was reconstructed successfully, and the total active motion of the injured finger was (225±22)° at the last follow-up, which was significantly higher than (117±20)° before surgery ( t=119.59, P<0.05); the foot function score was 86±7 at the last follow-up, which was significantly higher than 29±7 before surgery ( t=222.68, P<0.05), and the foot function was evaluated as excellent in 2 cases, good in 1 case, and acceptable in 1 case. Conclusions:The operation of harvesting the anterolateral femoral perforator flap pedicled with oblique branch of lateral circumflex femoral artery is relatively simple. After the wounds on hands or feet being repaired with the flaps, the appearance and function are good, with no obvious scar hyperplasia in donor and recipient areas of flaps. The fascia lata carried by the flap can repair the extensor tendon defect at the same time and improve the movement of the finger/toe.
2.The effect of different stent oversize on lumen remodeling of endovascular repair of type B aortic dissection
Zhigang PEI ; Haijie CHE ; Lubin LI ; Guolong LIU ; Mu YANG ; Wenqiang NIU ; Zhongzhen YANG ; Hengyang DONG ; Benxiang YU
Chinese Journal of General Surgery 2023;38(1):28-32
Objective:To investigate the effect of different stent oversize in thoracic endovascular aortic repair (TEVAR) on lumen remodeling of type B aortic dissection (TBAD).Methods:The clinical and follow-up data of 89 TBAD patients receiving TEVAR from Nov 2010 to Jun 2020 at Yantai Yuhuangding Hospital were retrospectively analyzed. According to the difference of proximal stent oversize, 89 patients were divided into: low oversize group (<10%, 47 cases) and high oversize group (≥10%, 42 cases). The changes of the normal vessel diameter and area at the proximal end of the stent and the long diameter, short diameter and area of the true/false lumen at the distal end of the stent at 3, 6, and 12 months after surgery and postoperative complications were analyzed.Results:The change of proximal vessel diameter with time in the low oversize group is smaller than that in the high oversize group ( P<0.05),and the change of the distal false lumen area of the stent in the low oversize group was greater than that in the high oversize group ( P<0.05). The high oversize group was prone to retrograde type A aortic dissection (RTAD) ( P<0.05). Conclusion:Low oversize stents are more conducive to the remodeling of the aortic lumen in the early and mid-term after TEVAR in TBAD patients.
3.Design of anterolateral thigh perforator flap aided by three-dimensional printing technique for repairing irregular extremity wounds
Chengwei GE ; Guodong JIANG ; Kai WANG ; Zhigang CHE ; Junnan CHENG ; Zhicheng TENG ; Song YUAN ; Jihui JU
Chinese Journal of Plastic Surgery 2024;40(9):946-953
Objective:To investigate the clinical effect of three-dimensional(3D) flap model accurately designed before the operation in repairing irregular wounds of limbs with anterolateral thigh(ALT) perforator flap.Methods:The data of patients with ALT flaps designed with 3D printing technology to repair irregular soft tissue defects of limbs in Suzhou Ruihua Orthopedic Hospital from January to October 2022 were retrospectively analyzed. After the wound was scanned by 3D scanner before surgery, the wound model was printed. The ALT flap was precisely designed and harvested for covering the wound according to the body surface projection of the perforator vessel in the anterolateral femoral region located by color Doppler ultrasound before surgery. The survival of the flap, the healing of the donor and recipient sites and the occurrence of complications were observed and followed up after the operation. The effect of wound repair was evaluated by the comprehensive efficacy evaluation scale of the skin flap. The total score was 100 points, which was divided into excellent (90-100 points), good (75-89 points), fair (60-74 points) and poor (< 60 points).Results:A total of 34 patients were enrolled, including 26 males and 8 females, aged 18-75 years, with an average age of 45.5 years. Injury sites: wrist in 17 cases, foot in 10 cases, ankle in 7 cases. The operation time was 2.0-4.5 h (mean 3.3 h), and all donor sites were sutured directly. Vascular crisis occurred in 2 cases after skin flap transplantation. After surgical exploration, the transplanted skin flap survived, and the other skin flaps survived successfully. All 34 patients were followed up for 6 to 10 months, with an average of 8 months. All the donor sites of the skin flap healed primarily, and the wound healing time of the recipient site was 10-44 days, with an average of 20 days. At the last follow-up, the skin flap was good in color and texture, and the sensation returned to S1 and S2 grades. There were scars left in the donor site, no cicatricial contracture, pain and other discomfort, and no other serious complications. The results of flap evaluation were 80-91 points, with an average of 86 points. Among them, 25 cases were excellent, 6 cases were good, 3 cases were fair, and the excellent and good rate was 91%(31/34).Conclusion:The application of 3D printing technology assisted the design of ALT perforator flap to repair irregular wounds of limbs can significantly reduce the intraoperative design time of the flap, which is in line with the concept of precise design and incision of the flap, and has good clinical effect, and can effectively reduce the trauma and complications of the donor site.
4.Design of anterolateral thigh perforator flap aided by three-dimensional printing technique for repairing irregular extremity wounds
Chengwei GE ; Guodong JIANG ; Kai WANG ; Zhigang CHE ; Junnan CHENG ; Zhicheng TENG ; Song YUAN ; Jihui JU
Chinese Journal of Plastic Surgery 2024;40(9):946-953
Objective:To investigate the clinical effect of three-dimensional(3D) flap model accurately designed before the operation in repairing irregular wounds of limbs with anterolateral thigh(ALT) perforator flap.Methods:The data of patients with ALT flaps designed with 3D printing technology to repair irregular soft tissue defects of limbs in Suzhou Ruihua Orthopedic Hospital from January to October 2022 were retrospectively analyzed. After the wound was scanned by 3D scanner before surgery, the wound model was printed. The ALT flap was precisely designed and harvested for covering the wound according to the body surface projection of the perforator vessel in the anterolateral femoral region located by color Doppler ultrasound before surgery. The survival of the flap, the healing of the donor and recipient sites and the occurrence of complications were observed and followed up after the operation. The effect of wound repair was evaluated by the comprehensive efficacy evaluation scale of the skin flap. The total score was 100 points, which was divided into excellent (90-100 points), good (75-89 points), fair (60-74 points) and poor (< 60 points).Results:A total of 34 patients were enrolled, including 26 males and 8 females, aged 18-75 years, with an average age of 45.5 years. Injury sites: wrist in 17 cases, foot in 10 cases, ankle in 7 cases. The operation time was 2.0-4.5 h (mean 3.3 h), and all donor sites were sutured directly. Vascular crisis occurred in 2 cases after skin flap transplantation. After surgical exploration, the transplanted skin flap survived, and the other skin flaps survived successfully. All 34 patients were followed up for 6 to 10 months, with an average of 8 months. All the donor sites of the skin flap healed primarily, and the wound healing time of the recipient site was 10-44 days, with an average of 20 days. At the last follow-up, the skin flap was good in color and texture, and the sensation returned to S1 and S2 grades. There were scars left in the donor site, no cicatricial contracture, pain and other discomfort, and no other serious complications. The results of flap evaluation were 80-91 points, with an average of 86 points. Among them, 25 cases were excellent, 6 cases were good, 3 cases were fair, and the excellent and good rate was 91%(31/34).Conclusion:The application of 3D printing technology assisted the design of ALT perforator flap to repair irregular wounds of limbs can significantly reduce the intraoperative design time of the flap, which is in line with the concept of precise design and incision of the flap, and has good clinical effect, and can effectively reduce the trauma and complications of the donor site.
5.Pathological diagnosis of lung cancer based on deep transfer learning
Dan ZHAO ; Nanying CHE ; Zhigang SONG ; Cancheng LIU ; Lang WANG ; Huaiyin SHI ; Yujie DONG ; Haifeng LIN ; Jing MU ; Lan YING ; Qingchan YANG ; Yanan GAO ; Weishan CHEN ; Shuhao WANG ; Wei XU ; Mulan JIN
Chinese Journal of Pathology 2020;49(11):1120-1125
Objective:To establish an artificial intelligence (AI)-assisted diagnostic system for lung cancer via deep transfer learning.Methods:The researchers collected 519 lung pathologic slides from 2016 to 2019, covering various lung tissues, including normal tissues, adenocarcinoma, squamous cell carcinoma and small cell carcinoma, from the Beijing Chest Hospital, the Capital Medical University. The slides were digitized by scanner, and 316 slides were used as training set and 203 as the internal test set. The researchers labeled all the training slides by pathologists and establish a semantic segmentation model based on DeepLab v3 with ResNet-50 to detect lung cancers at the pixel level. To perform transfer learning, the researchers utilized the gastric cancer detection model to initialize the deep neural network parameters. The lung cancer detection convolutional neural network was further trained by fine-tuning of the labeled data. The deep learning model was tested by 203 slides in the internal test set and 1 081 slides obtained from TCIA database, named as the external test set.Results:The model trained with transfer learning showed substantial accuracy advantage against the one trained from scratch for the internal test set [area under curve (AUC) 0.988 vs. 0.971, Kappa 0.852 vs. 0.832]. For the external test set, the transferred model achieved an AUC of 0.968 and Kappa of 0.828, indicating superior generalization ability. By studying the predictions made by the model, the researchers obtained deeper understandings of the deep learning model.Conclusions:The lung cancer histopathological diagnostic system achieves higher accuracy and superior generalization ability. With the development of histopathological AI, the transfer learning can effectively train diagnosis models and shorten the learning period, and improve the model performance.