1.The application effect of a new type of laparoscopic multi-freedom surgical instrument in the training of basic surgical skills
Zhida CHEN ; Jianhan YIN ; Yi LIU ; Tingting LU ; Gan ZHANG ; Xiaoyu DONG ; Xiaohui DU ; Hongqing XI
Chinese Journal of Surgery 2024;62(11):1045-1053
Objective:To evaluate the application effect of a new type of laparoscopic multi-degree-of-freedom surgical instrument in the training of basic surgical skills and analyze the learning curve.Methods:The teaching records of the trainees who received training in the training base of laparoscopic surgeons in Chinese People′s Liberation Army General Hospital from January to October, 2023 were collected. The 50 trainees were randomly divided into conventional instrumentation group and new instrumentation group with 25 trainees in each group according to the random number table method before the training. According to the research design, five modules such as "accurate bean clamping, plum blossom pile bean clamping, ferrule positioning, threading with both hands, sewing and knotting" were trained. After the training, they were assessed and the completion time of each module was recorded. The comparison of the changes of the completion time of the two groups of students before and after training was statistically analyzed by differences-in-differences(DID) method, and the fitting analysis of learning curve was analyzed by cumulative summation method .Results:Before the training, there was no statistically significant difference in the time required to complete five modules between the two groups of trainees (all P>0.05). After the training, the time to complete the five modules in both groups was reduced compared to before the training (accurate bean clamping: (63.7±9.3) seconds vs. (85.4±18.2) seconds, t=2.38, P=0.035; plum blossom pile bean clamping: (45.2±6.8) seconds vs. (103.1±57.2) seconds, t=8.77, P=0.047; ring positioning: (78.5±19.1) seconds vs. (126.2±26.3) seconds, t=6.96, P=0.019; threading with both hands: (63.3±21.2) seconds vs. (105.8±27.9) seconds, t=3.43, P=0.015; sewing and knotting: (160.2±79.5) seconds vs. (228.9±96.6) seconds, t=4.58, P=0.008).The average time required to complete the five modules was shorter in the new instrument group compared to the conventional instrument group (DID for accurate bean clamping=37.66, t=2.43, P=0.007; DID for plum blossom pile bean clamping=58.42, t=3.03, P=0.013; DID for ferrule positioning=28.33, t=2.83, P=0.031; DID for threading with both hands=48.89, t=2.10, P=0.042; DID for sewing and knotting=54.78, t=3.57, P=0.012). In the learning curves for the plum blossom pile bean clamping, ferrule positioning, and sewing and knotting modules, the new instrument group required fewer class hours to reach proficiency compared to the conventional instrument group (plum blossom pile bean clamping: 3 class hours vs. 4 class hours; ferrule positioning: 4 class hours vs. 5 class hours; sewing and knotting: 3 class hours vs. 5 class hours). In the accurate bean clamping and threading with both hands modules, both the conventional and new instrument groups crossed the learning curve at the 5 th class hour, but there was a statistically significant difference in the slopes of the curves between the two groups (accurate bean clamping: t=-2.85, P=0.004; threading with both hands: t=-2.66, P=0.008). Conclusion:The new type of laparoscopic multi-degree-of-freedom surgical instruments can improve the learning effect and shorten the learning curve in laparoscopic training teaching, which shows good application effect and has the possibility of clinical trial.
2.Construction of long term restenosis prediction model for patients with severe subpatellar artery lesions in type 2 diabetes treated with paclitaxel coated balloon
Feng LIN ; Lingxiong CHEN ; Yu LIU ; Xuming ZHANG ; Zhida YIN ; Tanhui LIN ; Zunrong LIU
Tianjin Medical Journal 2024;52(8):830-835
Objective To analyze influencing factors of paclitaxel coated ballon(PCB)on long-term restenosis in patients with severe subpatellar artery lesions in type 2 diabetes mellitus(T2DM),and to construct a prediction model.Methods A total of 268 T2DM patients with severe infra-popliteal artery disease and received PCB treatment were selected.Patients were followed up for 1 year after treatment.Patients with target vessel restenosis were included in the observation group,and the other patients were included in the control group.Clinical data of two groups were analyzed.Multivariable Logistic regression analysis was used to analyze influencing factors of long-term restenosis in T2DM patients with severe infra-knee arterial disease,and a nomogram prediction model was constructed.Results A total of 260 patients(97.00%)completed the follow-up,and the incidence of restenosis was 13.85%(36/260).Both univariate and multivariate Logistic regression analysis showed that age,coexisting coronary heart disease,Trans-Atlantic Inter-Society Consensus(TASC)Ⅱ classification,Fontaine staging,glycosylated hemoglobin(HbA1c)and low density lipoprotein cholesterol(LDL-C)were independent influencing factors for the occurrence of long-term restenosis in T2DM patients with severe infra-popliteal artery disease(P<0.05).The risk factor with the highest score in the constructed nomogram prediction model was HbA1c,followed by age,LDL-C,TASCⅡ classification,Fontaine stage and coronary heart disease.According to the column chart,the total score was 210 points,and the probability of long-term restenosis was 90%.The discrimination of the nomogram model was 0.866,with a Brier score of 0.081 and a calibration slope of 0.733.When the risk threshold was 0.15 to 1.0,the net benefit rate of long-term restenosis in T2DM patients with severe infra-popliteal artery disease was greater than that of individual evaluation.The smaller the risk threshold,the greater the net benefit rate.The benefit was the best when the threshold reached 0.23.Conclusion The influencing factors for long-term restenosis in T2DM patients with severe subknee artery disease treated by PCB include age,combined coronary heart disease,TASCⅡ grade,Fontaine stage,HbA1c and LDL-C.The prediction model based on the above influencing factors has important value in predicting long-term restenosis in patients.
3.The application effect of a new type of laparoscopic multi-freedom surgical instrument in the training of basic surgical skills
Zhida CHEN ; Jianhan YIN ; Yi LIU ; Tingting LU ; Gan ZHANG ; Xiaoyu DONG ; Xiaohui DU ; Hongqing XI
Chinese Journal of Surgery 2024;62(11):1045-1053
Objective:To evaluate the application effect of a new type of laparoscopic multi-degree-of-freedom surgical instrument in the training of basic surgical skills and analyze the learning curve.Methods:The teaching records of the trainees who received training in the training base of laparoscopic surgeons in Chinese People′s Liberation Army General Hospital from January to October, 2023 were collected. The 50 trainees were randomly divided into conventional instrumentation group and new instrumentation group with 25 trainees in each group according to the random number table method before the training. According to the research design, five modules such as "accurate bean clamping, plum blossom pile bean clamping, ferrule positioning, threading with both hands, sewing and knotting" were trained. After the training, they were assessed and the completion time of each module was recorded. The comparison of the changes of the completion time of the two groups of students before and after training was statistically analyzed by differences-in-differences(DID) method, and the fitting analysis of learning curve was analyzed by cumulative summation method .Results:Before the training, there was no statistically significant difference in the time required to complete five modules between the two groups of trainees (all P>0.05). After the training, the time to complete the five modules in both groups was reduced compared to before the training (accurate bean clamping: (63.7±9.3) seconds vs. (85.4±18.2) seconds, t=2.38, P=0.035; plum blossom pile bean clamping: (45.2±6.8) seconds vs. (103.1±57.2) seconds, t=8.77, P=0.047; ring positioning: (78.5±19.1) seconds vs. (126.2±26.3) seconds, t=6.96, P=0.019; threading with both hands: (63.3±21.2) seconds vs. (105.8±27.9) seconds, t=3.43, P=0.015; sewing and knotting: (160.2±79.5) seconds vs. (228.9±96.6) seconds, t=4.58, P=0.008).The average time required to complete the five modules was shorter in the new instrument group compared to the conventional instrument group (DID for accurate bean clamping=37.66, t=2.43, P=0.007; DID for plum blossom pile bean clamping=58.42, t=3.03, P=0.013; DID for ferrule positioning=28.33, t=2.83, P=0.031; DID for threading with both hands=48.89, t=2.10, P=0.042; DID for sewing and knotting=54.78, t=3.57, P=0.012). In the learning curves for the plum blossom pile bean clamping, ferrule positioning, and sewing and knotting modules, the new instrument group required fewer class hours to reach proficiency compared to the conventional instrument group (plum blossom pile bean clamping: 3 class hours vs. 4 class hours; ferrule positioning: 4 class hours vs. 5 class hours; sewing and knotting: 3 class hours vs. 5 class hours). In the accurate bean clamping and threading with both hands modules, both the conventional and new instrument groups crossed the learning curve at the 5 th class hour, but there was a statistically significant difference in the slopes of the curves between the two groups (accurate bean clamping: t=-2.85, P=0.004; threading with both hands: t=-2.66, P=0.008). Conclusion:The new type of laparoscopic multi-degree-of-freedom surgical instruments can improve the learning effect and shorten the learning curve in laparoscopic training teaching, which shows good application effect and has the possibility of clinical trial.