1.Analysis of prescription errors made by outpatient electronic prescription system
Zhibo CAI ; Yan LIN ; Miaolian WU
Chinese Journal of Hospital Administration 2008;24(12):852-855
Errors in prescriptions are common phenomena in prescriptions produced by clinicians. With development and application of information technology in medical fields, electronic prescription system has been regarded as the best resolution for effective prevention of errors in prescriptions. A retrospective study of the prescriptions made by the electronic prescription system of the hospital studied over one year showed that this system could reduce errors easily made in manual prescriptions significantly, but it failed to reduce the errors related to dosages. Those dosage-related errors were mainly caused by change of physician prescribing behavior and defective man-machine interaction. Electronic prescription system, though functions basically, can not avoid prescription errors effectively, which poses a potential threat to safe use of medicines in patients. It is urgent at the moment to perfect the functions of electronic prescription system, promote a friendly man-machine interaction and reduce errors made by system errors.
2.A Clinic Research About Bronchoscopic Lung Volume Reduction By ?-cyanoacrylate.
Zhibo LI ; Shu-Mei LIN ; Qi-Xiao FENG ;
Chinese Journal of Practical Internal Medicine 2006;0(S1):-
Objective To research the method and effect about the bronchoscopic lung volume reduction by ?-cyanoac- rylate in the therapy of chronic obstructive pulmonary disease (COPD).Methods The 14 patients had been examined bosoms by CT before the operation and determined the type of emphysema and the distributing of pneumatocele,had blood gas analyzed and pulmonary function checked.The operation was carried through trachea cannula and intravenous anesthe- sia.When the bronchoscope came to the goal bronchia,we infused the meglumine diatrizoate through the biopsy orifice and approved the location of pneumatocele forward。Then,we infused erythromycin and ?-cyanoacrylate in turn through the biopsy orifice by silica del tube.Results The 3 pneumothorax patients had been removed the drainage tube in 3 days af- ter the operation.8 cases had been counterchecked sternite in one week and the pneumatocele was just like before,among which,1 case developed exudation.1 case had shown pleural thickening in the right-up lung counterchecked sternite 9 months later.1 case been checked the pulmonary function,the FEV_1 enhanced from 24.7% pred before operation to 32. 9% pred after operation one week.3 cases felt polypnea improved greatly and 7 cases felt polypnea improved a little.Con- clusion The bronchoscopic lung volume reduction by ?-cyanoacrylate is a safe,effective and economical method in the therapy of COPD.
3.Evaluation of endovascular radiofrequency ablation combined with TACE in treatment of portal vein tumor thrombus of primary hepatocellular carcinoma
Zhongwu CHEN ; Zhengyu LIN ; Zhibo ZHANG ; Yiping CHEN ; Jin CHEN
Chinese Journal of Interventional Imaging and Therapy 2017;14(9):525-529
Objective To cvaluate the efficacy and safety of HabibTM VesOpen intravascular radiofrequency catheter percutaneous radiofrequency ablation combined with TACE in the treatment of portal vein tumor thrombus of primary hepatocellular carcinoma.Methods Thirty-nine patients with primary hepatocellular carcinoma complicated with portal vein thrombosis were treated with HabibTM VesOpen intracavitary catheter ablation combined with TACE.The postoperative success rate,complication,blood index,α-fetoprotein (AFP),portal vein patency and tumor thrombus imaging changes were assessed.Results All of 39 patients underwent surgery successfully without occurrence of perforation,infection,hepatapostema,intra-abdominal hemorrhage nor other complications associated with surgery.Blood routine examinations (WBC,RBC,PLT) after 2 weeks and 4 weeks of surgery had no statistical difference compared with those of preoperation.Liver function indexes including ALT,AST,ALB had statistical difference before and after the surgery except for TBIL.AFP had statistical difference before and after surgery.Doppler ultrasonography after 4 weeks showed blood flow in original blocked portal vein.Enhanced CT or MR examinations after 8 weeks on the abdomen,suggested that tumors were shrinked or disappeared.Conclusion Radiofrequency catheter ablation with intracavitary radiofrequency catheter of HabibTM VesOpen is an effective method in the treatment of portal vein tumor thrombus in primary hepatocellular carcinoma.
4.Status quo and legitimacy analysis for temporarily dispensed drugs used in hospitals
Zhibo CAI ; Yan LIN ; Yu WANG ; Bingyi SHENG
Chinese Journal of Hospital Administration 2009;25(4):266-269
Availability of appropriate drugs for children has been a bottleneck both at home and abroad for years.As a result, drugs for adults that are market available emerge a choice of convenience for children's treatment instead.For unique physiological and psychological characteristics of children, these drugs must be dispensed on individual basis before usage to children in question.Such drugs play a key role in children's treatment, and incur many problems on the other hand in their use and practice, such as drug stability, dosage accuracy, potential risks, as well as legitimacy in drug dispensing and use.A safe, reasonable and normalized use of such drugs calls for an orchestrated effort among pharmacists, trade associations and drug regulators as well.
5.Integrated Development of Full-automatic Fluorescence Analyzer.
Mei ZHANG ; Zhibo LIN ; Peng YUAN ; Zhifeng YAO ; Yueming HU
Journal of Biomedical Engineering 2015;32(5):1118-1124
In view of the fact that medical inspection equipment sold in the domestic market is mainly imported from abroad and very expensive, we developed a full-automatic fluorescence analyzer in our center, presented in this paper. The present paper introduces the hardware architecture design of FPGA/DSP motion controlling card+PC+ STM32 embedded micro processing unit, software system based on C# multi thread, design and implementation of double-unit communication in detail. By simplifying the hardware structure, selecting hardware legitimately and adopting control system software to object-oriented technology, we have improved the precision and velocity of the control system significantly. Finally, the performance test showed that the control system could meet the needs of automated fluorescence analyzer on the functionality, performance and cost.
Automation, Laboratory
;
Equipment Design
;
Fluorescence
;
Software
6.Combination of bioactive glass and chitosan as a bone repair material
Chen SUN ; Shaobo ZHU ; Zhihong YU ; Zhibo SUN ; Baiwen QI ; Tao ZHANG ; Lin JIN ; Muhaimaiti MAIHEMUTIJIANG
Chinese Journal of Tissue Engineering Research 2013;(51):8907-8913
BACKGROUND:Bioactive glass, a multi-phase composite material, has good biological activity, bone conductivity and biocompatibility, but as a bone repair material it cannot be completely degraded, and has low mechanical strength that is insufficient.
OBJECTIVE:To design a kind of bioactive glasses/chitosan composite scaffold, and to investigate its physicochemical properties and cellcompatibility.
METHODS:Hydrochloric acid solution containing 2.0%chitosan was mixed withβ-glycerophosphate at a radio of 7:1 to prepare chitosan solution. Bioactive glasses of 0.5, 1.0, 1.5 g were added into the prepared chitosan solution, and the mass ratios of chitosan and bioactive glass were 2:1, 1:1, and 1:1.5 respectively. The composite materials were immersed and mineralized in simulated body fluid for 7 days.
RESULTS AND CONCLUSION:Scanning electron microscopy showed that the composite scaffold had an interconnected porous structure with the porosity of 89%and the pore size of 100-300μm;bioactive glasses dispersed in a needle shape between the chitosan scaffolds, arranged evenly, and were ful y wrapped tightly by the scaffolds. With the increase in mass of bioactive glass, the porosity of the composites decreased, but the fracture strength gradual y increased. There was a positive correlation between the composite porosity and fracture strength. X-ray diffraction and Fourier transform infrared spectroscopy confirmed that the composite scaffold appeared to have no changes in the nature of single materials, and differential scanning calorimetry analysis showed no mass loss at normal body temperature. After 3 days of mineralization, hydroxyapatite forming on the material surface gradual y grew up as a vil ous shape, and also significantly increased in number. After 7 days of mineralization, hydroxyapatite changed from a vil ous shape to a needle shape, the amount of hydroxyapatite was increased further, and many mineralized products were in a spherical shape.
7.Study on the Whitening activity and pathway of red eucommia herbs
Jinbin LIN ; Tong REN ; Yijiang LIAN ; Weijie LI ; Xin JIN ; Zhibo XIA ; Wenjun LI
Chinese Journal of Biochemical Pharmaceutics 2015;(12):21-23,28
Objective To determine the impact of PEE with different ethanol concentration extract on the activity of tyrosinase in B16 melanoma and to explore the feasibility of PEE used as skin whitening agent make use of a model organism .Methods 30%, 50%, 70%, 95%, different concentration of ethanol reflux got four kinds of PEE alcohol extract, respectively.And selected the most active inhibition to mushroom tyrosinase ( PEE30、PEE50、PEE70、PEE95).The effect of extracts from the selected on B16 cell model was determined by MTS, NaOH splitting decomposition, L-DOPA oxidation progress.The change in protein expression level after ethanol extract of PEE was determined by Western bolt.Results The capacity of inhibition to mushroom tyrosinase in each concentration of PEE extraction, but PEE70 had the most active inhibition.When challenged with B16 cell model, PEE70 showed the capacity of decrease in tyrosinase activities and melanin synthesis (P<0.01) and had a does dependence ;it also decreased Tyrosinase and TRP-1 expression compared with control B16 cells.Conclusion These data support the idea that PEE can restrain melanogenesis, through its inhibitory effect on the activity of tyrosinase.
8.Facial Nerve Monitoring in Patients Under The Low Level Of Neuromuscular Blockade During Resection Of acoustic Neurinomas
Lingyan WANG ; Quan HUANG ; Nan JIANG ; Heng ZHANG ; Zhengsong HUANG ; Jinlong LIU ; Zhibo XIA ; Jiaping LIN
Chinese Journal of Nervous and Mental Diseases 2010;36(2):96-99
Objective To perform facial nerve monitoring in patients under the low level of neuromuscular blockade during resection of acoustic neurinomas.Methods Twenty-eight patients with large,or medium acoustic neuroma underwent the surgery of acoustic neurinomas resection. During the operation,TOF and EEG monitoring were performed in order to detect the degree of muscle relaxation and the depth of anesthesia. Neuromuscular relaxation was maintained at T_4/T_1=25%~50% by adjusting doses of muscle relaxant and aneasthetic. Free-run EMG and Triggered EMG of orbicularis oris, orbicularis oculi, masseter and trapezius were recordered to monitor the function of the facial, trigeminal and accessory nerves, respectively. The function of the facial nerve was evaluated at first week and half year postoperatively according to House-brackmann classification.Results The facial never was successfully identified and mapped by neurominitoring in all 28 patients. successfully, tThe electrical stimulation was 0.1 mA-0.3 mA and no any involuntary body movement was observed in all patients ne of patients have moved during operation. The preservation of the facial nerve function following surgery was good. Five patients had a HB grade I, 13 a HB grade II, 8 a grade III and 2 a HB grade IV The facial nerve function was HB Grade Ⅰin 5 of 28 patients, HB GradeⅡ in 13, HB Grade Ⅲ in 8 and HB Grade Ⅳ in 2 immediately after operation. Six months after surgery, 10 casespatents showed demonstrated a HB GradeⅠof facial never function, 12 cases exhibited a slight palsy (HB Grade II) , and 5 cases exhibited a HB Grade III palsy and . Another 1 cases a exhibited severe palsy (HB Grade IV).Conclusions Facial nerve monitoring in patients under the low level of neuromuscular blockade can ensure the surgical safety and preserve the facial never function.
9.Comparative study of USPIO-enhanced and Gd-enhanced MRI in the diagnosis of atherosclerotic plaques in rabbits
Luchao WANG ; Gongxin LI ; Peng LIU ; Zhibo WEN ; Fanheng HUANG ; Liheng CHEN ; Xin ZHAO ; Lin LIN ; Yijun ZHOU
The Journal of Practical Medicine 2014;(5):684-687
Objective To investigate the imaging characteristics of USPIO-enhanced and Gd-enhanced MRI in atherosclerosis and to compare the detection rate of atherosclerotic plaque between them. Methods Thirty-five healthy male rabbits were assigned to experimental group (n=30) to establish a model of atherosclerosis by damaging aortic tunica intima with Foley′s tube in combination with a high fat diet and 5 to control group without any intervention. At week 12, USPIO-enhanced and Gd-enhanced MRI scanning were conducted to compare the signal changes of atherosclerotic plaque before and after enhancement with the 2 contrast media. Ninety seven pictures were randomly selected respectively from the pictures enhanced by the 2 contrast media to compare the detection rate plaque between them. Pthology examination was used for detection standard. For the control group , pictures were randomly selected. Results In the experimental group, 7 rabbits died of Foley′s tube damaging, 2 died of raising and 1 died of anesthesia. All 5 rabbits in control group survived. A total of 172 pathological sections were made with 134 plaques and 72 vulnerable plaques pathologically confirmed. In pictures enhanced by USPIO , 84 plaques were confirmed by HE staining with a detection rate of 86.6%. In pictures enhanced by Gd, 72 plaques were confirmed by HE staining with a detection rate of 74.2%. Detection rate of USPIO-enhanced MRI in atherosclerosis plaque was significantly higher than that of Gd-enhanced MRI (X2=3.96, P=0.046). Conclusion USPIO shows its superiority as a new contrast medium in detection of atherosclerosis plaque.
10.Comparison of visual quality following different methods of YAG laser posterior capsulotomy for posterior capsular opacification
Zhibo LIN ; Ding CHEN ; Xiaofen FENG ; Fang HUANG ; Qinmei WANG
Chinese Journal of Experimental Ophthalmology 2019;37(4):282-286
Objective To evaluate and compare the subjective and objective visual quality of YAG laser posterior capsulotomy.Methods A series of case observation study was designed.Twenty-eight patients (38 eyes)underwent Nd:YAG laser posterior capsulotomy in the Eye Hospital of Wenzhou Medical University were retrospectively collected from 2015 to 2016.Patients were divided into circular capsulotomy group (20 patients 23 eyes) and cruciate capsulotomy group (12 patients 15 eyes) based on the capsulotomy technique (round incision of posterior capsule or cross incision of posterior capsule).The uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) were examined before and 2 weeks after operation,the intraocular pressure was also measured before operation,1 hour after operation and 2 weeks after operation.The Strehl ratio (SR),modulation transfer function (MTF) cut-off,objective scatter index (OSI),OQAS values (OVs) were analyzed by Two-channel visual quality analysis system OQAS Ⅱ at 1 h and 2 weeks after operation.The changes of intraocular scattering and visual quality at 1 h and 2 weeks after operation with different posterior capsulotomy methods were compared and analyzed.Results At 2 weeks after operation,the UCVA was 0.18±0.15 and 0.16±0.14,and the BCVA was 0.10±0.10 and 0.10±0.11,respectively in the circular capsulotomy group and cruciate capsulotomy group,which was higher than those before operation (all at P<0.05),but there was no significant difference in UCVA and BCVA between the two groups (all at P>0.05).There was no significant difference in intraocular pressure between the two groups at 1 hour and 2 weeks after operation (both at P>0.05).In the circular capsulotomy group,the incidence of black shadow drift was 39.1% and 30.4% respectively at 1 hour and 2 weeks after operation,which was higher than that in the cruciate capsulotomy group (6.7% and 6.7 %),with no significant differences between the two groups (P =0.065,0.177).No significant difference were found in the incidence of black shadow drift before eyes between the two groups (P>0.05),and there was no significant differences in the OQAS parameters OSI,MTF,SR,OV100%,OV20% and OV9% between the two groups (all at P>0.05).Conclusions After Nd:YAG laser capsulotomy,the incidence of black shadow drift in the cruciate capsulotomy group is lower than that in the circular capsulotomy group.There is no significant difference in the visual acuity,intraocular pressure,intraocular scattering and visual quality parameters between circular posterior capsulotomy and cross posterior capsulotomy.