1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Impact of VA-ECMO combined with IABP and timing on outcome of patients with acute myocardial infarction complicated with cardiogenic shock.
Chen Liang PAN ; Jing ZHAO ; Si Xiong HU ; Peng LEI ; Cun Rui ZHAO ; Yu Run SU ; Wei Ting CAI ; Shan Shan ZHANG ; Zhi Jie YAN ; An Dong LU ; Bo ZHANG ; Ming BAI
Chinese Journal of Cardiology 2023;51(8):851-858
Objective: To investigate the impact of combined use and timing of arterial-venous extracorporeal membrane oxygenation (VA-ECMO) with intra-aortic balloon pump (IABP) on the prognosis of patients with acute myocardial infarction complicated with cardiogenic shock (AMICS). Methods: This was a prospective cohort study, patients with acute myocardial infarction and cardiogenic shock who received VA-ECMO support from the Heart Center of Lanzhou University First Hospital from March 2019 to March 2022 in the registration database of the Chinese Society for Extracorporeal Life Support were enrolled. According to combination with IABP and time point, patients were divided into VA-ECMO alone group, VA-ECMO+IABP concurrent group and VA-ECMO+IABP non-concurrent group. Data from 3 groups of patients were collected, including the demographic characteristics, risk factors, ECG and echocardiographic examination results, critical illness characteristics, coronary intervention results, VA-ECMO related parameters and complications were compared among the three groups. The primary clinical endpoint was all-cause death, and the safety indicators of mechanical circulatory support included a decrease in hemoglobin greater than 50 g/L, gastrointestinal bleeding, bacteremia, lower extremity ischemia, lower extremity thrombosis, acute kidney injury, pulmonary edema and stroke. Kaplan-Meier survival curves were used to analyze the survival outcomes of patients within 30 days of follow-up. Using VA-ECMO+IABP concurrent group as reference, multivariate Cox regression model was used to evaluate the effect of the combination of VA-ECMO+IABP at different time points on the prognosis of AMICS patients within 30 days. Results: The study included 68 AMICS patients who were supported by VA-ECMO, average age was (59.8±10.8) years, there were 12 female patients (17.6%), 19 cases were in VA-ECMO alone group, 34 cases in VA-ECMO+IABP concurrent group and 15 cases in VA-ECMO+IABP non-concurrent group. The success rate of ECMO weaning in the VA-ECMO+IABP concurrent group was significantly higher than that in the VA-ECMO alone group and the VA-ECMO+IABP non-concurrent group (all P<0.05). Compared with the ECMO+IABP non-concurrent group, the other two groups had shorter ECMO support time, lower rates of acute kidney injury complications (all P<0.05), and lower rates of pulmonary edema complications in the ECMO alone group (P<0.05). In-hospital survival rate was significantly higher in the VA-ECMO+IABP concurrent group (28 patients (82.4%)) than in the VA-ECMO alone group (9 patients) and VA-ECMO+IABP non-concurrent group (7 patients) (all P<0.05). The survival rate up to 30 days of follow-up was also significantly higher surviving patients within were in the ECMO+IABP concurrent group (26 cases) than in VA-ECMO alone group (9 patients) and VA-ECMO+IABP non-concurrent group (4 patients) (all P<0.05). Multivariate Cox regression analysis showed that compared with the concurrent use of VA-ECMO+IABP, the use of VA-ECMO alone and non-concurrent use of VA-ECMO+IABP were associated with increased 30-day mortality in AMICS patients (HR=2.801, P=0.036; HR=2.985, P=0.033, respectively). Conclusions: When VA-ECMO is indicated for AMICS patients, combined use with IABP at the same time can improve the ECMO weaning rate, in-hospital survival and survival at 30 days post discharge, and which does not increase additional complications.
Humans
;
Female
;
Middle Aged
;
Aged
;
Shock, Cardiogenic/complications*
;
Extracorporeal Membrane Oxygenation/methods*
;
Pulmonary Edema/complications*
;
Aftercare
;
Prospective Studies
;
Patient Discharge
;
Myocardial Infarction/therapy*
;
Intra-Aortic Balloon Pumping/methods*
;
Treatment Outcome
;
Retrospective Studies
7.Impact of VA-ECMO combined with IABP and timing on outcome of patients with acute myocardial infarction complicated with cardiogenic shock.
Chen Liang PAN ; Jing ZHAO ; Si Xiong HU ; Peng LEI ; Cun Rui ZHAO ; Yu Run SU ; Wei Ting CAI ; Shan Shan ZHANG ; Zhi Jie YAN ; An Dong LU ; Bo ZHANG ; Ming BAI
Chinese Journal of Cardiology 2023;51(8):851-858
Objective: To investigate the impact of combined use and timing of arterial-venous extracorporeal membrane oxygenation (VA-ECMO) with intra-aortic balloon pump (IABP) on the prognosis of patients with acute myocardial infarction complicated with cardiogenic shock (AMICS). Methods: This was a prospective cohort study, patients with acute myocardial infarction and cardiogenic shock who received VA-ECMO support from the Heart Center of Lanzhou University First Hospital from March 2019 to March 2022 in the registration database of the Chinese Society for Extracorporeal Life Support were enrolled. According to combination with IABP and time point, patients were divided into VA-ECMO alone group, VA-ECMO+IABP concurrent group and VA-ECMO+IABP non-concurrent group. Data from 3 groups of patients were collected, including the demographic characteristics, risk factors, ECG and echocardiographic examination results, critical illness characteristics, coronary intervention results, VA-ECMO related parameters and complications were compared among the three groups. The primary clinical endpoint was all-cause death, and the safety indicators of mechanical circulatory support included a decrease in hemoglobin greater than 50 g/L, gastrointestinal bleeding, bacteremia, lower extremity ischemia, lower extremity thrombosis, acute kidney injury, pulmonary edema and stroke. Kaplan-Meier survival curves were used to analyze the survival outcomes of patients within 30 days of follow-up. Using VA-ECMO+IABP concurrent group as reference, multivariate Cox regression model was used to evaluate the effect of the combination of VA-ECMO+IABP at different time points on the prognosis of AMICS patients within 30 days. Results: The study included 68 AMICS patients who were supported by VA-ECMO, average age was (59.8±10.8) years, there were 12 female patients (17.6%), 19 cases were in VA-ECMO alone group, 34 cases in VA-ECMO+IABP concurrent group and 15 cases in VA-ECMO+IABP non-concurrent group. The success rate of ECMO weaning in the VA-ECMO+IABP concurrent group was significantly higher than that in the VA-ECMO alone group and the VA-ECMO+IABP non-concurrent group (all P<0.05). Compared with the ECMO+IABP non-concurrent group, the other two groups had shorter ECMO support time, lower rates of acute kidney injury complications (all P<0.05), and lower rates of pulmonary edema complications in the ECMO alone group (P<0.05). In-hospital survival rate was significantly higher in the VA-ECMO+IABP concurrent group (28 patients (82.4%)) than in the VA-ECMO alone group (9 patients) and VA-ECMO+IABP non-concurrent group (7 patients) (all P<0.05). The survival rate up to 30 days of follow-up was also significantly higher surviving patients within were in the ECMO+IABP concurrent group (26 cases) than in VA-ECMO alone group (9 patients) and VA-ECMO+IABP non-concurrent group (4 patients) (all P<0.05). Multivariate Cox regression analysis showed that compared with the concurrent use of VA-ECMO+IABP, the use of VA-ECMO alone and non-concurrent use of VA-ECMO+IABP were associated with increased 30-day mortality in AMICS patients (HR=2.801, P=0.036; HR=2.985, P=0.033, respectively). Conclusions: When VA-ECMO is indicated for AMICS patients, combined use with IABP at the same time can improve the ECMO weaning rate, in-hospital survival and survival at 30 days post discharge, and which does not increase additional complications.
Humans
;
Female
;
Middle Aged
;
Aged
;
Shock, Cardiogenic/complications*
;
Extracorporeal Membrane Oxygenation/methods*
;
Pulmonary Edema/complications*
;
Aftercare
;
Prospective Studies
;
Patient Discharge
;
Myocardial Infarction/therapy*
;
Intra-Aortic Balloon Pumping/methods*
;
Treatment Outcome
;
Retrospective Studies
8.Therapeutic Effect of Ershen Pill () Extract on Pi (Spleen)-Shen (Kidney) Yang Deficiency-Induced Diarrhea in Rat Model.
Xin PAN ; Kang XU ; Rui XIONG ; Zhi-Min CHEN ; Chang-Jiang HU ; Jian FENG ; Wen-Bin LI
Chinese journal of integrative medicine 2019;25(7):536-542
OBJECTIVE:
To investigate whether Ershen Pill (ESP, ) could alleviate the symptom of Pi (Spleen)-Shen (Kidney) yang deficiency (PSYD)-induced diarrhea in rat model and explore its anti-diarrhea mechanism.
METHODS:
Seventy-five Sprague-Dawley rats were divided into 5 groups by a random number table, including control, positive, model, low-dose (LD) and high-dose (HD) ESP groups, 15 rats in each group. All the rats, except those in the control group, were developed PSYD induced-diarrhea based on its pathology and etiology. The rats in positive, LD and HD ESP groups were treated with Shenling Baizhu Pill (), LD (1.05 g/kg) or HD (3.50 g/kg) ESP petroleum ether extract once a day for 2 weeks, respectively. Body weight change and diarrhea index were measured. The histology scores of the kidney were evaluated via hematoxylin and eosin (HE) staining. Aquaporin-3 (AQP3) expression in the colon was analyzed by immunofluorescence, quantitative reverse transcription-polymerase chain reaction (qRT-PCR) and Western blot, respectively.
RESULTS:
Compared with the model group, oral administration of LD and HD ESP prevented body weight loss and inhibited diarrhea after 2-week treatment (P<0.05). Kidney deterioration was impeded, and the histology score in LD and HD ESP groups were 8.2 and 10.5, respectively, which were both higher than those in the model group (P<0.05). In addition, ESP treatment alleviated rat colitis, and HD ESP significantly improved the AQP3 positive staining intensity in the colon tissue compared with the model group. The result from Western blot revealed that AQP3 protein synthesis in colon tissue of LD and HD ESP groups increased by 2.1- and 5.9-fold compared with the model group (P<0.05). qRT-PCR result showed that AQP3 gene expression in the HD ESP group was also up-regulated by 2.5-fold normalized to the model group (P<0.05).
CONCLUSION
ESP extract effectively alleviates the symptoms of PSYD and relieves PSYD-induced diarrhea by improving AQP3 synthesis in the colon.
10.Surgical treatment of pregnancy complicated with aortic dissection
GUO Qiannan ; LI Ku ; ZHU Shuo ; TAN Decai ; XIONG Tianxin ; ZHU Guizhi ; ZHENG Zhi ; PAN Youmin ; WANG Haihao ; LI Jun
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2018;25(11):956-961
Objective To summarize the characteristics and management of pregnancy complicated with aortic dissection, and to explore the reasonable diagnosis and treatment plan. Methods The clinical data of 10 patients of pregnancy complicated with aortic dissection in Wuhan Tongji Hospital from January 2011 to June 2017 were collected. Their age was 25.2 (21-29) years. Results In the 10 patients, the majority (8 patients) were primipara, and most of them were in the late stages of pregnancy (5 patients) and puerperal (4 patients). Among them, 1 patient had gestational hypertension, and the blood pressure of the left and right upper extremities was significantly abnormal (initial blood pressure: left upper limb blood pressure: 90/60 mm Hg, right upper limb blood pressure: 150/90 mm Hg). The major clinical manifestations were severe chest and back pain which happened suddenly, with D-dimmer and C-creative protein increased which may be associated with inflammatory reaction. All patients were diagnosed by thoracoabdominal aortic CTA, including 5 patients of Stanford type A dissection and 5 patients of Stanford type B dissection. In the 10 patients, 1 patient refused surgery and eventually died of aortic rupture with the death of fetus before birth. And the remaining 9 patients underwent surgical treatment, 3 patients of endovascular graft exclusion for thoracic aortic stent graft, 2 patients underwent Bentall operation, 1 patient with Bentall + total aortic arch replacement + vascular thoracic aortic stent graft, 1 patient with Bentall operation combined with endovascular graft exclusion for thoracic aortic stent graft, 1 patient with Bentall + coronary artery bypass grafting, 1 patient of thoracoabdominal aortic vascular replacement. Among them, 1 patient underwent endovascular graft exclusion for thoracic aortic stent graft died of severe postoperative infection, and the remaining 8 patients were discharged from hospital. Nine patients were single birth, among them 5 newborn patients had severe asphyxia, 4 patients had mild asphyxia. Finally, 3 neonates died of severe complications, and the remaining 6 survived. Conclusion The ratio of pregnancy with Stanford type A aortic dissection is far higher than in the general population, the possibility of fetal intrauterine asphyxia is larger, but through active and effective surgical and perioperative treatment, we can effectively save the life of mother and fetus.


Result Analysis
Print
Save
E-mail