1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Clinical efficacy of endocrinotherapy combined with Shenqi Pills on patients with hormone-sensitive prostate cancer.
Yu-Hong XIE ; Gang YI ; Xiao-Wen YI ; Tong-Lin SUN ; Qun-Fang LIN ; Jun ZHOU ; Xin-Jun LUO ; Fang-Zhi FU ; Biao WANG ; Qin-Zheng WANG ; Lie ZHANG ; Yang YANG ; Rui-Song GAO ; Qing ZHOU
National Journal of Andrology 2025;31(4):341-348
OBJECTIVE:
The aim of this study is to explore the clinical efficacy and safety of endocrinotherapy combined with Shenqi Pills on hormone-sensitive prostate cancer (HSPC).
METHODS:
Eighty patients who were diagnosed with HSPC and renal-yang deficiency at the First Affiliated Hospital of Hunan University of Traditional Chinese Medicine and the Hospital of Traditional Chinese Medicine of Mayang Miao Autonomous County from 1st April 2021 to 30th April 2024 were randomly divided into 2 groups. The patients in the control group were treated with androgen deprivation therapy (ADT). And the patients in treatment group were treated with Shenqi Pills orally on the basis of the control group. The baseline data of the two groups were analyzed. After 36 months of treatment, the differences between the two groups were compared in terms of overall survival (OS), prostate-specific antigen (PSA) level, PSA response rate, Functional Assessment Scale for Prostate Cancer Therapy (FACT-P), Chinese medicine evidence scores, testosterone level and safety.
RESULTS:
A total of 80 study subjects were included in this study, including 42 cases in the treatment group and 38 cases in the control group. There was no statistical difference in the baseline data between the two groups before treatment (P>0.05). At the end of the observation period, a statistically significant difference in OS was found in the treatment group compared to the control group in the subgroup of patients with a disease duration ranged of 0-6 months (P<0.05). There was no statistically significant difference in PSA levels in the treatment group at 3 months (P>0.05). And the differences in the proportion of PSA50 (98.1% vs 91.4%), PSA90 (92.9% vs 84.6%) and the proportion of decrease in PSA (56.7% vs 33.8%) in the treatment group were found compared to those in the control group after 6 months of tre atment. After 12 months of treatment, the scores of FACT-4 and renal-yang deficiency in the treatment group were (95.28±7.93) and (15.73±5.70) respectively, compared to the scores in the control group ([85.46±10.12] and [18.20±4.27] (P<0.05). However, there was no significant difference in serum testosterone ([0.60±0.24] nmol/L vs [1.09±2.10] nmol/L) between the two groups (P>0.05). After 24 months of treatment, there were significant differences in in the FACT-4 total score ([97.95±7.54] vs [80.33±8.58]), renal-yang deficiency syndrome score ([14.64±5.15] vs [24.94±8.75]) between the treatment group and the control group (P<0.05). However, there was no significant difference in serum testosterone ( [0.73±1.01] nmol/L vs [0.59±0.25] nmol/L) between the two groups (P> 0.05). Better therapeutic results were showed in the treatment group in terms of total FACT-P score, physical situation score, social and family situation score, emotional state score, functional state score, additional score and renal-yang deficiency symptom score (P<0.05). After treatment, there was no serious adverse reaction in the course of treatment, and no obvious abnormality was found in the liver and kidney function of the patients from two groups.
CONCLUSION
Endocrinotherapy combined with Shenqi Pills is safe and effective in HSPC and can reduce the risk of death in HSPC patients, and the earlier the intervention, the longer the overall survival of the patients. In addition, this treatment regimen can increase the PSA response rate, improve patients' quality of life, and reduce the renal-yang deficiency syndrome score without the risk of elevating serum testosterone levels.
Humans
;
Male
;
Drugs, Chinese Herbal/therapeutic use*
;
Prostatic Neoplasms/drug therapy*
;
Androgen Antagonists/therapeutic use*
;
Prostate-Specific Antigen/blood*
;
Aged
;
Middle Aged
;
Treatment Outcome
;
Testosterone
7.Qingda Granule Attenuates Hypertension-Induced Cardiac Damage via Regulating Renin-Angiotensin System Pathway.
Lin-Zi LONG ; Ling TAN ; Feng-Qin XU ; Wen-Wen YANG ; Hong-Zheng LI ; Jian-Gang LIU ; Ke WANG ; Zhi-Ru ZHAO ; Yue-Qi WANG ; Chao-Ju WANG ; Yi-Chao WEN ; Ming-Yan HUANG ; Hua QU ; Chang-Geng FU ; Ke-Ji CHEN
Chinese journal of integrative medicine 2025;31(5):402-411
OBJECTIVE:
To assess the efficacy of Qingda Granule (QDG) in ameliorating hypertension-induced cardiac damage and investigate the underlying mechanisms involved.
METHODS:
Twenty spontaneously hypertensive rats (SHRs) were used to develope a hypertension-induced cardiac damage model. Another 10 Wistar Kyoto (WKY) rats were used as normotension group. Rats were administrated intragastrically QDG [0.9 g/(kg•d)] or an equivalent volume of pure water for 8 weeks. Blood pressure, histopathological changes, cardiac function, levels of oxidative stress and inflammatory response markers were measured. Furthermore, to gain insights into the potential mechanisms underlying the protective effects of QDG against hypertension-induced cardiac injury, a network pharmacology study was conducted. Predicted results were validated by Western blot, radioimmunoassay immunohistochemistry and quantitative polymerase chain reaction, respectively.
RESULTS:
The administration of QDG resulted in a significant decrease in blood pressure levels in SHRs (P<0.01). Histological examinations, including hematoxylin-eosin staining and Masson trichrome staining revealed that QDG effectively attenuated hypertension-induced cardiac damage. Furthermore, echocardiography demonstrated that QDG improved hypertension-associated cardiac dysfunction. Enzyme-linked immunosorbent assay and colorimetric method indicated that QDG significantly reduced oxidative stress and inflammatory response levels in both myocardial tissue and serum (P<0.01).
CONCLUSIONS
Both network pharmacology and experimental investigations confirmed that QDG exerted its beneficial effects in decreasing hypertension-induced cardiac damage by regulating the angiotensin converting enzyme (ACE)/angiotensin II (Ang II)/Ang II receptor type 1 axis and ACE/Ang II/Ang II receptor type 2 axis.
Animals
;
Drugs, Chinese Herbal/therapeutic use*
;
Hypertension/pathology*
;
Renin-Angiotensin System/drug effects*
;
Rats, Inbred SHR
;
Oxidative Stress/drug effects*
;
Male
;
Rats, Inbred WKY
;
Blood Pressure/drug effects*
;
Myocardium/pathology*
;
Rats
;
Inflammation/pathology*
8.Real-time Analysis of Organic Composition of Oral and Nasal Breath Air by High Resolution Mass Spectrometry
Kang-Yi WANG ; Chen TAO ; Xin LUO ; Zhi-Feng TANG ; Te BAI ; Hang LI ; Li-Gang HU ; Wei ZHANG ; Xue LI
Chinese Journal of Analytical Chemistry 2024;52(1):72-79,中插14-中插37
Human exhaled breath has great application prospects,e.g.,monitoring pharmacokinetics,disease diagnosis,due to its advantages such as non-invasive and high-frequency sampling.Breath samples can be collected from the oral and nasal cavity.However,the oral and nasal environment affect the chemical composition of breath sample.Therefore,the investigation on the chemical composition of mouth-exhaled breath and nose-exhaled breath is crucial for selection of appropriate sampling strategy for individual studies.In this work,secondary electrospray ionization-high resolution mass spectrometry(SESI-HRMS)was applied to analysis of respiratory metabolomics in real time.A quantitative analysis approach was established for 9 kinds of volatile organic compounds(VOCs)e.g.2-butanone,2-pentanone,ethyl acetate,methyl methacrylate,toluene,styrene,mesitylene,isoprene and limonene.The limit of detection was 2.3?240.8 ng/m3.The intra-day(n=6)and inter-day(n=18)relative standard deviations were 0.6%?4.6%and 4.3%?12.2%,respectively.Nine healthy subjects were recruited to investigate the chemical composition of mouth-exhaled and nose-exhaled breath.The results showed the good performance in quantitative analysis of 9 VOCs in breath air.It was found that the number of unique component(m/z)detected in mouth-exhaled breath(167)was 2.2 times greater than that detected in nose-exhaled breath(76),which might result from the complex environment in oral cavity.The signal intensity of commun component(163)was significantly different between mouth-exhaled breath and nose-exhaled breath.Additionally,the elemental composition analysis showed that the proportion of polar compounds detected in nose-exhaled breath was higher than that in mouth-exhaled breath.This study demonstrated that there was significant differences in the chemical composition between mouth-exhaled and nose-exhaled breath,which provided a theoretical basis for selection of exhalation mode.
9.Reconstruction of Allen's type IV fingertip amputation via bilateral unequal-sized hallux osteo-onychocutaneous free flaps: A retrospective study with 5-year follow-up
Xiu-Zhong LI ; Xiu-Yun WANG ; Yi-Min ZHOU ; Da-Zhi YU ; Hua-Gang ZHANG ; Shu-Jian HOU ; Ke-Cheng LAO ; Xiao FAN
Chinese Journal of Traumatology 2024;27(6):403-409
Purpose::The reconstruction of Allen's type IV fingertip amputation is a clinical challenge. Our team designed bilateral unequal-sized hallux osteo-onychocutaneous free flaps for the long-term reconstruction of Allen's type IV fingertip amputation and conducted a retrospective study with a 5-year follow-up aims to evaluate the effects of this technique.Methods::A retrospective analysis with a 5-year follow-up including 13 patients with Allen's type IV fingertip amputation who were admitted to our hospital from January 2010 to January 2017 was conducted. The patients were treated with bilateral unequal-sized hallux osteo-onychocutaneous free flaps. The operation time, intraoperative blood loss, and complications were recorded, and the survival rate of the transplanted flaps was calculated. During the 5-year follow-up after operation, the nail growth time was recorded and the finger appearance was observed. At the last follow-up appointment, the length, width, and girth of the reconstructed fingertip and contralateral normal fingertip, range of motion of the reconstructed fingertip and contralateral normal fingertip, Semmes-Weinstein test (for the evaluation of tactile sensation), and two-point discrimination testing results were recorded. SPSS 22.0 software was used for the statistical analysis and the data are presented as mean ± SD.Results::The mean operation time was (5.62 ± 0.51) h, the mean intraoperative blood loss was (34.15 ± 3.13) mL, and the survival rate of the transplanted flaps was 100%. During the 5-year follow-up, the average nail growth time was (10.14 ± 1.98) months and the average bone union time was (3.78 ± 0.91) months. The length, width, and girth of the reconstructed fingertip were (31.52 ± 3.73) mm, (17.82 ± 1.74) mm, and (59.75 ± 3.04) mm, respectively, which did not differ from those of the contralateral normal fingertip. The range of motion of the reconstructed fingertip was (12.15 ± 2.79) degrees which is different from that of the contralateral normal fingertip. The average tactile sensation evaluated via the Semmes-Weinstein test and the average two-point discrimination test of the reconstructed fingertip were (0.39 ± 0.17) g and (7.46 ± 1.14) mm, respectively, which were not different from those of the contralateral normal fingertip. The average Maryland score of feet in the donor area was 87.66 ± 7.39, which was satisfactory.Conclusion::Bilateral unequal-sized hallux osteo-onychocutaneous free flaps are an effective method to reconstruct Allen's type IV fingertip amputations with a satisfactory appearance and good sensory function.
10.Insight of N-Lauroyl-L-alanine Molecular Assembly Using Solid-State Nuclear Magnetic Resonance Technique
Zi-Hui QIU ; Ling-Yun XU ; Yi-Jian CHEN ; Hong-Chun DONG ; Jie SHU ; Zhi-Gang YAO
Chinese Journal of Analytical Chemistry 2024;52(6):866-875
Amino acid surfactants (AAS) have excellent properties such as low toxicity,antibacterial,mildness,and corrosion resistance. In recent years,they have been widely applied in the field of daily chemicals,food and pharmaceutical industry. It is pointed out that the structure at molecular level largely affects the physical and chemical properties of AAS materials. In this work,the structures of solid-state N-lauroyl-L-alanine (NLLA) including intermolecular interactions,molecular local dynamics and molecular assembly were investigated by a variety of solid-state nuclear magnetic resonance (SSNMR) techniques. Based on 2D 1H-1H double quantum-single quantum (2D 1H-1H DQ-SQ),1H-1H DQ sideband pattern and molecular simulation,it was found that there was a stable intermolecular hydrogen bond formed between the carboxyl units of two NLLA molecules. Combined with the study of 2D frequency switched Lee—Goldberg heteronuclear correlation (2D 13C-1H FSLG-HETCOR) and 13C T1,another type of hydrogen bond was probed,which existed between amide units of neighboring molecules. In addition,the conformation of alkyl chain ends was investigated. According to 1D 13C{1H}cross polarization/magic angle spinning (CP/MAS) and 2D 13C-1H FSLG-HETCOR spectra,it was revealed that the alkyl-chain ends had both gauche and trans conformations. Moreover,the trans conformation showed two distinct 13C chemical shifts,originated from two NLLA molecular assembly forms. Accordingly,two NLLA molecular assembly structures were suggested which were transoid form and cisoid form. This work provided a SSNMR investigation strategy for characterizing the molecular local structure and dynamics of AAS materials,which helped task of researching and developing materials with improved chemical and physical properties.

Result Analysis
Print
Save
E-mail