1.Research advance on the role of gut microbiota and its metabolites in juvenile idiopathic arthritis.
Ao-Hui PENG ; You-Jia CHEN ; Jin-Xuan GU ; Zhi-Gang JIN ; Xu-Bo QIAN
Acta Physiologica Sinica 2025;77(3):587-601
Juvenile idiopathic arthritis (JIA) is the most common condition of chronic rheumatic disease in children. JIA is an autoimmune or autoinflammatory disease, with unclear mechanism and limited treatment efficacy. Recent studies have found a number of alterations in gut microbiota and its metabolites in children with JIA, which are related to the development and progression of JIA. This review focuses on the influence of the gut microbiota and its metabolites on immune function and the intestinal mucosal barrier and discuss the key role of the gut-joint axis in the pathogenesis of JIA and emerging treatment methods based on gut microbiota and its metabolites. This review could help elucidate the pathogenesis of JIA and identify the potential therapeutic targets for the prevention and treatment of JIA.
Humans
;
Arthritis, Juvenile/physiopathology*
;
Gastrointestinal Microbiome/physiology*
;
Child
;
Intestinal Mucosa
2.Exploration of differences in decoction phase state, material form, and crystal form between Glycyrrhizae Radix et Rhizoma-Gypsum Fibrosum and Glycyrrhizae Radix et Rhizoma-CaSO_4·2H_2O based on supramolecules of traditional Chinese medicine.
Yao-Zhi ZHANG ; Wen-Min PI ; Xin-Ru TAN ; Ran XU ; Xu WANG ; Ming-Yang XU ; Xue-Mei HUANG ; Peng-Long WANG
China Journal of Chinese Materia Medica 2025;50(2):412-421
With Glycyrrhizae Radix et Rhizoma-Gypsum Fibrosum drug pair as the research object, supramolecular chemistry of traditional Chinese medicine(TCM) was used to study differences between the compatibility of herbal medicine Glycyrrhizae Radix et Rhizoma with mineral medicine Gypsum Fibrosum and its main component CaSO_4·2H_2O, so as to preliminarily discuss the scientific connotation of compatibility of Gypsum Fibrosum in clinical application. A Malvern particle sizer, a scanning electron microscope(SEM), and a conductivity meter were used to observe and determine the physical properties such as microscopic morphology, particle size, and conductivity of Gypsum Fibrosum, CaSO_4·2H_2O, and water decoctions of them with Glycyrrhizae Radix et Rhizoma. An inductively coupled plasma optical emission spectrometer(ICP-OES) was employed to detect the inorganic metal elements in Glycyrrhizae Radix et Rhizoma-Gypsum Fibrosum and Glycyrrhizae Radix et Rhizoma-CaSO_4·2H_2O. Isothermal titration calorimetry(ITC) was conducted to quantify the interactions of Gypsum Fibrosum and CaSO_4·2H_2O with Glycyrrhizae Radix et Rhizoma. A Fourier transform infrared spectrometer(FTIR) was used to analyze the characteristic absorption peak change of Glycyrrhizae Radix et Rhizoma-Gypsum Fibrosum and Glycyrrhizae Radix et Rhizoma-CaSO_4·2H_2O. X-ray diffraction(XRD) was performed to determine the crystal structure and phase composition of Glycyrrhizae Radix et Rhizoma-Gypsum Fibrosum and Glycyrrhizae Radix et Rhizoma-CaSO_4·2H_2O. Further, glycyrrhizic acid(GA) was substituted for Glycyrrhizae Radix et Rhizoma to co-decoct with Gypsum Fibrosum, CaSO_4·2H_2O, and freeze-dried powder of their respective water decoctions. The results of XRD were used for verification analysis. The results showed that although CaSO_4·2H_2O is the main component of Gypsum Fibrosum, there were significant differences between their decoctions and between the decoctions of them with Glycyrrhizae Radix et Rhizoma. Specifically,(1) Both CaSO_4·2H_2O and Gypsum Fibrosum were amorphous fibrous. However, the particle size and conductivity were significantly different between the decoctions of CaSO_4·2H_2O and Gypsum Fibrosum alone.(2) Under SEM, Glycyrrhizae Radix et Rhizoma-CaSO_4·2H_2O was a hybrid system with various morphologies, while Glycyrrhizae Radix et Rhizoma-Gypsum Fibrosum presented uniform nanoparticles.(3) The particle sizes and conductivities of Glycyrrhizae Radix et Rhizoma-CaSO_4·2H_2O and Glycyrrhizae Radix et Rhizoma-Gypsum Fibrosum were significantly different and did not follow the same tendency as those of the decoctions of CaSO_4·2H_2O and Gypsum Fibrosum alone.(4) Compared with Glycyrrhizae Radix et Rhizoma-CaSO_4·2H_2O, Glycyrrhizae Radix et Rhizoma-Gypsum Fibrosum had stronger molecular binding ability and functional group structure change.(5) The crystal form was largely different between the freeze-dried powder of CaSO_4·2H_2O decoction and Gypsum Fibrosum decoction, and their crystal forms were also significantly different from those of the freeze-dried powder of Glycyrrhizae Radix et Rhizoma-CaSO_4·2H_2O and Glycyrrhizae Radix et Rhizoma-Gypsum Fibrosum decoctions. The reason for the series of differences is that Gypsum Fibrosum is richer in trace elements than CaSO_4·2H_2O. The XRD results of GA-Gypsum Fibrosum and GA-CaSO_4·2H_2O decoctions further prove the importance of trace elements in Gypsum Fibrosum for supramolecule formation. This research preliminarily reveals the influence of compatibility of Gypsum Fibrosum or CaSO_4·2H_2O on decoction phase state, material form, and crystal form, providing a basis for the rational clinical application of Gypsum Fibrosum.
Drugs, Chinese Herbal/chemistry*
;
Calcium Sulfate/chemistry*
;
Glycyrrhiza/chemistry*
;
Crystallization
;
Particle Size
;
Medicine, Chinese Traditional
;
Rhizome/chemistry*
3.Functional characterization of flavonoid glycosyltransferase AmGT90 in Astragalus membranaceus.
Guo-Qing PENG ; Bing-Yan XU ; Jian-Ping HUANG ; Zhi-Yin YU ; Sheng-Xiong HUANG
China Journal of Chinese Materia Medica 2025;50(6):1534-1543
Astragalus membranaceus(A. membranaceus), a traditional tonic, contains flavonoids as one of its main bioactive components and key indicators for quality standard detection. These compounds predominantly exist in glycosylated forms after glycosylation modification within the plant. The catalytic products of flavonoid glycosyltransferases in A. membranaceus have been reported to be mostly monoglycosides, and only AmUGT28 catalyzes luteolin to form diglycosides. In this study, we cloned a glycosyltransferase gene, AmGT90, from A. membranaceus, with an ORF length of 1 335 bp, encoding 444 amino acids, and the protein had a relative molecular mass of 50.5 kDa. Phylogenetic tree analysis indicated that AmGT90 belongs to the UGT74 family. In vitro enzymatic reaction showed that AmGT90 had broad substrate specificity and could catalyze the glycosylation of various flavonoids, including isoflavones, flavones, flavanones, and chalcones. AmGT90 not only catalyzed the formation of monoglycosides but also diglycosides. In addition, the mechanism of AmGT90 catalyzing the formation of diglycosides from luteolin was preliminarily explored. The experimental results showed that AmGT90 may preferentially recognize C4'-OH of luteolin and then recognize C7-OH to form diglycosides. This study reported a glycosyltransferase from A. membranaceus capable of converting flavonoids into monoglycosides and diglycosides. This finding not only enhances our understanding of the biosynthetic pathways of flavonoid glycosides in A. membranaceus but also introduces a new component for glycoside production through synthetic biology.
Glycosyltransferases/chemistry*
;
Flavonoids/chemistry*
;
Astragalus propinquus/classification*
;
Phylogeny
;
Glycosylation
;
Plant Proteins/chemistry*
;
Substrate Specificity
;
Cloning, Molecular
;
Amino Acid Sequence
4.Biomechanical advantages of personalized Y-shaped plates in treatment of distal humeral intra-articular fractures.
Hao YU ; Jiachen PENG ; Jibin YANG ; Lidan YANG ; Zhi XU ; Chen YANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):574-583
OBJECTIVE:
To compare the biomechanical properties of personalized Y-shaped plates with horizontal plates, vertical plates, and traditional Y-shaped plates in the treatment of distal humeral intra-articular fractures through finite element analysis, and to evaluate their potential for clinical application.
METHODS:
The study selected a 38-year-old male volunteer and obtained a three-dimensional model of the humerus by scanning his upper limbs using a 64-slice spiral CT. Four types of fracture-internal fixation models were constructed using Mimics 19.0, Geomagic Wrap 2017, Creo 6.0, and other software: horizontal plates, vertical plates, traditional Y-shaped plate, and personalized Y-shaped plate. The models were then meshed using Hypermesh 14.0 software, and material properties and boundary conditions were defined in Abaqus 6.14 software. AnyBody 7.3 software was used to simulate elbow flexion and extension movements, calculate muscle strength, joint forces, and load torques, and compare the peak stress and maximum displacement of the four fixation methods at different motion angles (10°, 30°, 50°, 70°, 90°, 110°, 130°, 150°) during elbow flexion and extension.
RESULTS:
Under dynamic loading during elbow flexion and extension, the personalized Y-shaped plate exhibits significant biomechanical advantages. During elbow flexion, the peak internal fixation stress of the personalized Y-shaped plate was (28.8±0.9) MPa, which was significantly lower than that of the horizontal plates, vertical plates, and traditional Y-shaped plate ( P<0.05). During elbow extension, the peak internal fixation stress of the personalized Y-shaped plate was (18.1±1.6) MPa, which was lower than those of the other three models, with significant differences when compared with horizontal plates and vertical plates ( P<0.05). Regarding the peak humeral stress, the personalized Y-shaped plate model showed mean values of (10.9±0.8) and (13.1±1.4) MPa during elbow flexion and extension, respectively, which were significantly lower than those of the other three models ( P<0.05). Displacement analysis showed that the maximum displacement of the humerus with the personalized Y-shaped plate during elbow flexion was (2.03±0.08) mm, slightly higher than that of the horizontal plates, but significantly lower than that of the vertical plates, showing significant differences ( P<0.05). During elbow extension, the maximum displacement of the humerus with the personalized Y-shaped plate was (1.93±0.13) mm, which was lower than that of the other three models, with significant differences when compared with vertical plates and traditional Y-shaped plates ( P<0.05). Stress contour analysis showed that the stress of the personalized Y-shaped plate was primarily concentrated at the bifurcation of the Y-shaped structure. Displacement contour analysis showed that the personalized Y-shaped plate effectively controlled the displacement of the distal humerus during both flexion and extension, demonstrating excellent stability.
CONCLUSION
The personalized Y-shaped plate demonstrates excellent biomechanical performance in the treatment of distal humeral intra-articular fractures, with lower stress and displacement, providing more stable fixation effects.
Humans
;
Male
;
Adult
;
Healthy Volunteers
;
Finite Element Analysis
;
Tomography, Spiral Computed
;
Models, Anatomic
;
Biomechanical Phenomena
;
Humeral Fractures, Distal/surgery*
;
Fracture Fixation, Internal/instrumentation*
;
Bone Plates
;
Computer Simulation
;
Precision Medicine/methods*
;
Elbow Joint/surgery*
;
Elbow/surgery*
;
Humerus/surgery*
;
Torque
;
Stress, Mechanical
;
Intra-Articular Fractures/surgery*
;
Prosthesis Design/methods*
;
Imaging, Three-Dimensional
;
Range of Motion, Articular
5.Clinical analysis of clavicle anatomical plate in the treatment of AllmanⅡC type of clavicle fracture.
Jian-Zhong GE ; Jin-Rui GU ; Peng XU ; Zhi-Ling ZHANG ; Kai WANG
China Journal of Orthopaedics and Traumatology 2025;38(7):711-715
OBJECTIVE:
To evaluate the clinical efficacy and safety of clavicular anatomical plate in the treatment of clavicular Allmanic fracture.
METHODS:
Between January 2016 and December 2022, 27 patients with Allman ⅡC distal clavicle fractures were treated with clavicular anatomical plate. There were 19 males and 8 females, aged from 16 to 69 years old, with an average of (39.74±12.71) years old. There were 15 patients on the left side and 12 patients on the right side. There were 15 patients with single clavicle fracture and 12 patients complicated with other parts of the body or organ injury. The broken ends of the fractures were fixed with clavicular anatomical plate, including common compression clavicular anatomical plate in 19 patients and locking clavicular anatomical plate in 8 patients. The operation time and hospitalization days were recorded. Visual analogue scales (VAS) were utilized to assess subjective pain levels both preoperatively and 3 days postoperatively. Postoperatively, patients were monitored at intervals of 1 to 3 months until X-ray films confirmed fracture healing. In accordance with the University of California, Los Angeles (UCLA) shoulder rating system, evaluations were conducted on postoperative pain alleviation, functional recovery, range of motion in forward flexion, strength in forward flexion, and patient satisfaction.
RESULTS:
All patients were followed up for a period ranging from 12 to 18 months with an average of (14.70±1.61) months, and all clavicular fractures achieved successful union. The wounds of 24 patients healed in one stage, and 3 patients developed bleeding and exudation, they were cured after dressing change. There were no complications such as infection, plate and screw fracture, vascular and nerve injury. The operation time was(67.56±11.01) min. Significant differences were observed in pain relief, functional improvement, range of motion for forward flexion, strength of forward flexion, patient satisfaction, and overall scores at preoperative, 3 months postoperatively, 6 months postoperatively, and at the final follow-up(P<0.001).
CONCLUSION
The utilization of clavicular anatomical plates for the management of Allman typeⅡC fractures can provide early and stable fixation without compromising the acromioclavicular joint, thereby enabling patients to commence early mobilization and ensuring optimal fracture healing.
Humans
;
Male
;
Female
;
Clavicle/surgery*
;
Adult
;
Bone Plates
;
Middle Aged
;
Fractures, Bone/physiopathology*
;
Adolescent
;
Aged
;
Fracture Fixation, Internal/instrumentation*
;
Young Adult
6.A finite element biomechanical study of anterior transpedicular root screw plate fixation system in the lower cervical spine.
Xiao-Ping XU ; Zhi-Peng HOU ; Liu-Jun ZHAO
China Journal of Orthopaedics and Traumatology 2025;38(8):848-855
OBJECTIVE:
To establish a two-segment vertebrectomy model using the finite element method, and to measure and compare the biomechanical properties of the lower cervical anterior transpedicular root screw (ATPRS) plate system, lower cervical anterior pedicle screw (ATPS) plate system, and lower cervical anterior cervical locked-plate (ACLP) system on this model.
METHODS:
CT data of the cervical spine (C0-T1) from a 34-year-old healthy adult male volunteer were collected. A nonlinear complete model of the lower cervical spine (C3-C7) was established using Mimics 10.01 software, based on which the ATPRS fixation model, ATPS fixation model, and ACLP fixation model were constructed respectively. An axial pressure of 75 N and a pure couple moment of 1.5 N·m were applied to C3 to make the model perform flexion-extension, left-right lateral bending, and left-right rotation movements. The range of motion (ROM) and stress distribution of each model under different working conditions were compared.
RESULTS:
The ROM of the C4-C7 segments in the ACLP group, ATPS group, and ATPRS group was reduced to 0.65° (-95.2%), 0.58° (-95.7%), and 0.62° (-95.4%) respectively compared with the intact model during flexion-extension movement;during lateral bending movement, it was reduced to 0.58° (-95.2%), 0.51°(-95.8%), and 0.60° (-95.1%) respectively;during rotation movement, it was reduced to 1.17° (-89.6%), 1.26° (-88.8%), and 1.27°(-88.7%) respectively. In terms of the stress on the titanium mesh graft, the ATPS group and ATPRS group had the maximum load during extension and the minimum load during flexion. Compared with the ACLP group, the stress on the titanium mesh graft in ATPS and ATPRS decreased by (-33.7%) and (-15.8%) in flexion, (-29.4%) and (-13.2%) in extension, (-26.2%) and (-23.4%) in lateral bending, and (-18.8%) and (-5.4%) in rotation, respectively. In terms of bone-screw interface stress, the peak bone stress near the C7 screw in the ACLP group, ATPS group, and ATPRS group increased by 49.2%, 45.0%, and 47.6% respectively compared with the peak bone stress near the C4 screw during extension. However, during flexion and lateral bending, there was no significant difference in the peak bone stress near the C4 and C7 screws. During rotation, the difference between the peak bone stress near the C4 screw and that near the C7 screw showed that in the ACLP group, left rotation (37.6%) was similar to right rotation (36.7%), while in the ATPS group and ATPRS group, left rotation was lower than right rotation.
CONCLUSION
Compared with the ACLP group, the ATPS group and ATPRS group have greater fixation stiffness and more stable fixation. However, in rotational movement, due to the uneven distribution of fixation stiffness, the stress distribution during torsion is uneven, but it is still better than the ACLP group. This indicates that ATPRS, like ATPS, has good primary stability, providing favorable conditions for bone graft fusion.
Humans
;
Finite Element Analysis
;
Male
;
Cervical Vertebrae/physiopathology*
;
Adult
;
Biomechanical Phenomena
;
Bone Plates
;
Bone Screws
;
Range of Motion, Articular
;
Fracture Fixation, Internal
7.Protective effect of sub-hypothermic mechanical perfusion combined with membrane lung oxygenation on a yorkshire model of brain injury after traumatic blood loss.
Xiang-Yu SONG ; Yang-Hui DONG ; Zhi-Bo JIA ; Lei-Jia CHEN ; Meng-Yi CUI ; Yan-Jun GUAN ; Bo-Yao YANG ; Si-Ce WANG ; Sheng-Feng CHEN ; Peng-Kai LI ; Heng CHEN ; Hao-Chen ZUO ; Zhan-Cheng YANG ; Wen-Jing XU ; Ya-Qun ZHAO ; Jiang PENG
Chinese Journal of Traumatology 2025;28(6):469-476
PURPOSE:
To investigate the protective effect of sub-hypothermic mechanical perfusion combined with membrane lung oxygenation on ischemic hypoxic injury of yorkshire brain tissue caused by traumatic blood loss.
METHODS:
This article performed a random controlled trial. Brain tissue of 7 yorkshire was selected and divided into the sub-low temperature anterograde machine perfusion group (n = 4) and the blank control group (n = 3) using the random number table method. A yorkshire model of brain tissue injury induced by traumatic blood loss was established. Firstly, the perfusion temperature and blood oxygen saturation were monitored in real-time during the perfusion process. The number of red blood cells, hemoglobin content, NA+, K+, and Ca2+ ions concentrations and pH of the perfusate were detected. Following perfusion, we specifically examined the parietal lobe to assess its water content. The prefrontal cortex and hippocampus were then dissected for histological evaluation, allowing us to investigate potential regional differences in tissue injury. The blank control group was sampled directly before perfusion. All statistical analyses and graphs were performed using GraphPad Prism 8.0 Student t-test. All tests were two-sided, and p value of less than 0.05 was considered to indicate statistical significance.
RESULTS:
The contents of red blood cells and hemoglobin during perfusion were maintained at normal levels but more red blood cells were destroyed 3 h after the perfusion. The blood oxygen saturation of the perfusion group was maintained at 95% - 98%. NA+ and K+ concentrations were normal most of the time during perfusion but increased significantly at about 4 h. The Ca2+ concentration remained within the normal range at each period. Glucose levels were slightly higher than the baseline level. The pH of the perfusion solution was slightly lower at the beginning of perfusion, and then gradually increased to the normal level. The water content of brain tissue in the sub-low and docile perfusion group was 78.95% ± 0.39%, which was significantly higher than that in the control group (75.27% ± 0.55%, t = 10.49, p < 0.001), and the difference was statistically significant. Compared with the blank control group, the structure and morphology of pyramidal neurons in the prefrontal cortex and CA1 region of the hippocampal gyrus were similar, and their integrity was better. The structural integrity of granulosa neurons was destroyed and cell edema increased in the perfusion group compared with the blank control group. Immunofluorescence staining for glail fibrillary acidic protein and Iba1, markers of glial cells, revealed well-preserved cell structures in the perfusion group. While there were indications of abnormal cellular activity, the analysis showed no significant difference in axon thickness or integrity compared to the 1-h blank control group.
CONCLUSIONS
Mild hypothermic machine perfusion can improve ischemia and hypoxia injury of yorkshire brain tissue caused by traumatic blood loss and delay the necrosis and apoptosis of yorkshire brain tissue by continuous oxygen supply, maintaining ion homeostasis and reducing tissue metabolism level.
Animals
;
Perfusion/methods*
;
Disease Models, Animal
;
Brain Injuries/etiology*
;
Swine
;
Male
;
Hypothermia, Induced/methods*
8.Single-incision laparoscopic totally extraperitoneal retrieval of retroperitoneal vas deferens in vasovasostomy for obstructive azoospermia patients postchildhood bilateral herniorrhaphy.
Chen-Wang ZHANG ; Wei-Dong WU ; Jun-Wei XU ; Jing-Peng ZHAO ; Er-Lei ZHI ; Yu-Hua HUANG ; Chen-Cheng YAO ; Fu-Jun ZHAO ; Zheng LI ; Peng LI
Asian Journal of Andrology 2025;27(1):137-138
9."A diamond-shaped" penoplasty technique with or without concurrent suprapubic liposuction for adult-acquired buried penis: clinical outcomes and patient satisfaction rates.
Jing WANG ; Jian NI ; Yang XU ; Wen YU ; Zhi-Peng XU ; Yu-Tian DAI ; Yi-Qiong YANG ; Xiao-Zhi ZHAO
Asian Journal of Andrology 2025;27(1):72-75
Various techniques have been described for reconstructing the skin of the penile shaft; however, no universally accepted standard exists for correcting buried penis in adults. We aimed to describe a new technique for correcting an adult-acquired buried penis through a diamond-shaped incision at the penopubic junction. We retrospectively analyzed data from patients treated with our technique between March 2019 and June 2023 in the Department of Andrology, Nanjing Drum Tower Hospital (Nanjing, China). Forty-two adult males with buried penises, with a mean (±standard deviation [s.d.]) age of 26.6 (±6.6) years, underwent surgery. All patients were obese, with an average (±s.d.) body mass index of 35.56 (±3.23) kg m -2 . In addition to phalloplasty, 32 patients concurrently underwent circumcision, and 28 underwent suprapubic liposuction. The mean (±s.d.) duration of the operation was 98.02 (±13.28) min. The mean (±s.d.) duration of follow-up was 6.71 (±3.43) months. The length in the flaccid unstretched state postoperatively was significantly greater than that preoperatively (mean ± s.d: 5.55±1.19 cm vs 1.94±0.59 cm, P < 0.01). Only minor complications, such as wound disruption (7.1%) and infection (4.8%), were observed. The mean (±s.d.) score of patient satisfaction was 4.02 (±0.84) on a scale of 5. This technique provides excellent cosmetic and functional outcomes with a minimal risk of complications. However, additional clinical studies are needed to evaluate the long-term effects of this procedure.
Humans
;
Male
;
Patient Satisfaction
;
Adult
;
Lipectomy/methods*
;
Penis/surgery*
;
Retrospective Studies
;
Treatment Outcome
;
Plastic Surgery Procedures/methods*
;
Young Adult
;
Penile Diseases/surgery*
;
Urologic Surgical Procedures, Male/methods*
10.Trend in testicular volume change after orchiopexy in 854 children with cryptorchidism.
Ying-Ying HE ; Zhi-Cong KE ; Shou-Lin LI ; Hui-Jie GUO ; Pei-Liang ZHANG ; Peng-Yu CHEN ; Wan-Hua XU ; Feng-Hao SUN ; Zhi-Lin YANG
Asian Journal of Andrology 2025;27(6):723-727
The aim of this study was to investigate the trend in testicular volume changes after orchiopexy in children with cryptorchidism. The clinical data of 854 children with cryptorchidism who underwent orchiopexy between January 2013 and December 2016 in Shenzhen Children's Hospital (Shenzhen, China) were retrospectively analyzed. The mean (standard deviation) age of the patients was 2.8 (2.5) years, and the duration of follow-up ranged from 1 year to 5 years. Ultrasonography was conducted preoperatively and postoperatively. The variables analyzed included age at the time of surgery, type of surgical procedure, laterality, preoperative testicular position, preoperative and postoperative testicular volumes, and the testicular volume ratio of them. The average testicular volumes preoperatively and at 1 year, 2 years, 3 years, and 5 years postoperatively were 0.27 ml, 0.38 ml, 0.53 ml, 0.87 ml, and 1.00 ml, respectively ( P < 0.001). The corresponding testicular volume ratios were 0.67, 0.76, 0.80, 0.83, and 0.84 ( P < 0.001). The mean volume of the undescended testes was significantly smaller than the mean normative value ( P < 0.001, lower than the 10 th percentile). The postoperative testicular volumes in children with cryptorchidism were generally lower than those in healthy boys but were still greater than the 10 th percentile and exhibited an increasing trend. The older the child is at the time of surgery, the larger the gap in volume between the affected and normal testes. Although testicular volume tends to gradually increase after orchiopexy for cryptorchidism, it could not normalizes. Earlier surgery results in affected testicular volumes closer to those of healthy boys.
Humans
;
Male
;
Cryptorchidism/diagnostic imaging*
;
Orchiopexy
;
Child, Preschool
;
Testis/surgery*
;
Retrospective Studies
;
Organ Size
;
Ultrasonography
;
Infant
;
Child
;
Postoperative Period
;
Follow-Up Studies

Result Analysis
Print
Save
E-mail