1.Prospective study of improved elasticity scores in the differential diagnosis of malignant and benign breast lesions
Baoming LUO ; Haiyun YANG ; Xiaoyun XIAO ; Hui ZHI ; Yanling WEN
Chinese Journal of Ultrasonography 2009;18(6):514-516
Objective To explore the value of improved elasticity scores in differentiating malignant and benign breast lesions. Methods A prospective study was done in 394 patients with 508 breast lesions confirmed by pathology and the elastographic images of the lesions were evaluated by using old and improved elasticity scores respectively. Results The elastographic images of the lesions could be evaluated and classified in all patients by improved elasticity scores but could not be evaluated and classified in 82 lesions by old elasticity scores. The accuracy of ultrasonic elastography for diagnosing benign and malignant breast lesions was 88.8% and 78.1%, respectively by old elasticity scores and improved elasticity scores. Conclusions The elastographic images of breast lesions were accurately evaluated by using improved elasticity scores, and the use of improved elasticity scores is helpful to reduce the biopsy which is not necessary.
2.Initial study of contrast-enhanced ultrasound 5-point scoring system in the diagnosis of breast tumor
Xiaoyun XIAO ; Hui ZHI ; Haiyun YANG ; Huan WU ; Baoming LUO
Chinese Journal of Ultrasonography 2012;21(4):328-331
Objective To explore the application of contrast-enhanced scoring system in the diagnosis of breast tumor.Methods 249 patients with 260 lesions were examined by elastography and contrastenhanced ultrasound before surgery.All the lesions were scored according to the two different methods.Pathological results were made the golden criteria.The diagnosis accuracy of the two methods were compared.Results There were 145 benign and 115 malignant tumors.The diagnosis accuracy,specificity and sensibility of elastography were 85.0%,88.3%,80.1 % respectively.The critical value of contrastenhanced ultrasound was between 3 and 4.The diagnosis accuracy,specificity and sensibility of contrastenhanced ultrasound were 88.9%,87.6%,90.4% respectively.Area under ROC curve of the two methods were 0.901 and 0.910,the difference was not statistically significant.Conclusions Contrast-enhanced ultrasound 5-point scoring system was an initial quantitative criterion for breast tumor diagnosis.The diagnosis accuracy was parallel to that of elastography.
3.Diagnostic value of ultrasonic elastography and conventional ultrasound in differentiating the benign and malignant hepatic tumors
Xinchuan ZHOU ; Hui ZHI ; Xiaoyun XIAO ; Baoming LUO
Chinese Journal of Ultrasonography 2011;20(11):950-952
Objective To evaluate the diagnostic value of conventional ultrasound and ultrasonic elastography (UE) in differentiating benign and malignant hepatic lesions.Methods One hundred and forty-five patients with 159 hepatic tumors were included in the study.Conventional ultrasound scan and UE were performed on each patient.Pathological results were as the golden standard.The diagnostic performance of the 2 methods were evaluated with receiver operating characteristic (ROC) curves and the interobserver agreements were analysed.Results A better interobserver agreement was achieved in UE (κ =0.325 at conventional ultrasound versus κ =0.782 at UE).The area under ROC curve of conventional ultrasound,ultrasonic elastography and the combination of both methods were 0.76,0.77 and 0.87,respectively.After the combination of the 2 methods,the sensitivity and accuracy could be enhanced significantly ( P <0.05).Conclusions Conventional ultrasound combined with UE may be more helpful in differentiating malignant from benign hepatic tumors.
4.Application of the binary Logistic regression mode to analyze ultrasonographic features of the solid breast tumors
Jie ZENG ; Baoming LUO ; Hui ZHI ; Haiyun YANG
Chinese Journal of Ultrasonography 2008;17(7):601-603
Objective To evaluate the application of the binary Logistic regression model to analyze ultrasonographie indexes of the solid breast tumors. Methods The indexes of two dimensional gray scale ultrasonography,two dimensional color Doppler flow imaging,three dimensional gray scale ultrasonography, three dimensional color Doppler flow imaging and ultrasonic elastography were evaluated in 151 breast lesions confirmed by surgical pathology. A Logistic regression model for predicting breast rnalignaney on the basis of ultrasonographic indexes was obtained. A receiver operating characteristic (ROC) curve was used to assess the performance of the Logistic regression model. Results Six ultrasonic indexes were finally entering the Logistic regression model. They were elasticity score, shape,internal echo, RI, enhancement of posterior acoustic alteration and the converging pattern in the coronal plane. The area under the ROC curve was 0. 996. The percentage correct of prediction was 97.35 %. Conclusions The multivariate analysis model of binary Logistic regression can describe and analyze the process of differential diagnosis of malignant and benign solid breast tumors by ultrasonography and can select out the valuable indexes of differential diagnosis.
6.Color Doppler ultrasound in the diagnosis of lower extremity arterial disease in patients with type 2 diabetes mellitus
Haiyun YANG ; Chuanjiang GAO ; Bing OU ; Hui ZHI ; Baoming LUO
Chinese Journal of Interventional Imaging and Therapy 2009;6(6):506-508
Objective To analyze the value of color Doppler ultrasound in the diagnosis of lower extremity arterial disease in patients with type 2 diabetes mellitus.Methods A total of 800 patients with type 2 diabetes mellitus underwent color Doppler ultrasonography to examine anterior tibial artery (ATA),dorsalis pedis artery (DPA) and posterior tibial artery (PTA).Ultrasonic findings including vascular diameter,stenosis ratio and hemodynamics of lower extremity arterial disease were analyzed retrospectively.Results ATA and DPA had more plaques and stenosis than PTA.There was no statistical difference of vascular diameter,stenosis ratio and hemodynamics between left and right lower extremity artery in patients with type 2 diabetes mellitus including diabetic foot.Conclusion Color Doppler ultrasound is a useful method in the diagnosis of lower extremity arterial disease in patients with type 2 diabetes mellitus,providing information of stenosis ratio and hemodynamics of lower extremity artery,so as contributing to the clinical therapy of this disease.
7.Diagnostic value of sound velocity and real-time ultrasonic elastographpy in differentiation benign or malignant of breast lesions
Bing OU ; Hui ZHI ; Haiyun YANG ; Baoming LUO
Chinese Journal of Ultrasonography 2013;(1):59-62
Objective To compare the diagnostic value of sound velocity(SV) and real-time ultrasonic elastography in differentiating benign or malignant of breast lesions.Methods 75 patients with 99 lesions were examined with the zone speed index technique and real-time ultrasonic elastography respectively.Then the SVs of the lesions were calculated and elastography of the lesions were scored with 5-scoring method.The ROC curves were constructed with histology as the golden standard.Results There was significant difference between the SVs of benign and malignant breast lesions(P =0.0001).1561 m/s was the best cufoff point.And the areas under the curves (AUC) of SV and real-time ultrasonic elastography were 0.842 and 0.968,respectively.There was significant difference between the two methods of AUC (P =0.023).The sensitivity,specificity and accuracy for SV were 81.5%,91.7%,88.9%,respectively.There was no significant difference between sensitivity,specificity and accuracy of the two methods(P =1.0,P =0.125,P =0.146).Conclusions Both SV method and real-time ultrasonic elastography are helpful in the evaluation of benign or malignant of breast lesions.
8.PCR-SSCP Analysis of the Pronucleus Microbial Communities in Luzhou-flavor Daqu
Hui-Bo LUO ; Zhi-Guo HUANG ; Hao LI ; Qiang ZHANG ; Chun-Hui WEI ;
Microbiology 2008;0(09):-
PCR-SSCP(single-strand conformation polymorphism) was used for studying the community changes of pronucleus microorganisms in various fermenting stages of Luzhou-flavor Daqu. The results showed:(1) The pronucleus microorganism's community was similar and also had the polymorphism in each simple of various fermentation stage;(2) Different microflora had complex ecology effects of coordination and the restriction;(3) The diversity indexes of different stage of Daqu microorganisms were around 1.69~2.01,and the composition of them was stable relatively;(4) The similarity indexes were 0.67~1.00,and much higher in the approaching stages.
9.Detective Significance of Cerebral Electrical Admittance Plethysmogram in Newborns with Asphyxia
ke-ying, ZHOU ; jin-zhi, SONG ; jing-zhi, LI ; hui, LUO ; xue-chang, XIAO ; zhi-guang, LI ; ben-qing, WU
Journal of Applied Clinical Pediatrics 2006;0(20):-
Objective To study hemodynamics of cerebral blood flow in newborns with asphyxia.Method Bilateral cerebral electrical admittance plethysmogram(BCEAP) was used to explore characteristics of cerebral blood flow in 20 healthy newborns and 20 newborns with asphyxia respectively from first to fourth day after birth.Results Both the ratio of Hs to b-S(Hs/ b-S) and index of admittance differential loop(ADL) Ⅰ+Ⅱ decreased significantly in newborns with asphyxia compared to normal control from first to fourth day after birth(P
10.Water arsenic, fluoride and chloride detection capability assessment of the drinking water monitoring Labs in Guangdong province
Zhi-xiong, ZHONG ; Li-ping, LIU ; Bing-hui, ZHU ; Chang-yun, HE ; Zhi-bin, LUO ; He-yan, WU
Chinese Journal of Endemiology 2011;30(4):453-455
Objective To assess the proficiency of water monitoring laboratory at rural, county, and provincial levels in Guangdong province, to ensure the province's drinking water monitoring results accurate and reliable. Methods State quality of certified reference materials as water arsenic, fluoride and chloride of 90 copies each were numbered and distributed to 90 monitoring laboratories in the province for testing, The measurement results of the participatory labs were evaluated through normative values and expanded uncertainty, and were compared with those of robust statistics method. Results All participatory labs had timely feedback of their measurement results. The qualified rate was higher when arsenic was tested by hydride generation atomic fluorescence spectrometry and zinc-new silver salt of sulfuric acid spectrophotometric system, while fluoride and chloride by ion chromatography. The average qualified rates of water arsenic, fluoride and chloride of the province's rural drinking water quality monitoring laboratory were 66% (59/90), 72% (65/90) and 72% (65/90), respectively.Seven participatory labs failed the proficiency testing of all three analytes and unqualified rate was 7.8% (7/90)among the ninety participated monitoring labs. The qualified rates of robust statistics method for arsenic fluoride and chloride were greater than those evaluated by the expanded uncertainty, and large deviations with small sample sizes. Conclusions The testing ability of drink-water monitoring labs in Guangdong province has improved.However, by comparison with the requirements of national quality control and testing skills, there is still a gap. It is suggested that internal quality control be included in routine inspeetion to improve laboratory testing technology.