1.Determination of Gastrodin in Tianyuan Granula by HPLC
Ying FENG ; Zhengyan XIA ; Qiang XU
Traditional Chinese Drug Research & Clinical Pharmacology 2009;20(4):354-356
Objective To establish a method for the determination of gastrodin in Tianyuan Granula. Methods The sample was refluxed with methanol, then eluted with 80 % ethanol through the alumina column(neutral). The chromato-graphic conditions were as follows: Diamonsil Cts chromatographic column(250 mm ×4.6 mm, 5 μm) with a mobile phase of acetonitrile-0. 15 % phosphoric acid (1 : 99), the detection wavelength being at 220 nm and the flow rate be-good (r=0.9999 95, n=7).The average recovery was 99.09 % and RSD=1. 50 % (n=6). Conclusion The method for determination of gastrodin in Tianyuan Granula is accurate, and with a good reproducibility.
2.Assay of ephedrina hydrochloridum and pseudoephedrine hydrochloride in Chuanliting Spray by HPLC
Shudan ZHANG ; Zhengyan XIA ; Ying FENG
Chinese Traditional Patent Medicine 1992;0(09):-
AIM: To establish a RP-HPLC method for determining ephedrina hydrochloridum and pseudoephedrine hydrochloride in Chuanliting Spray(Herba Ephedrae,Folium Artenisiae argyi,Radix et Rhizoma Asari,etc.). METHODS: HPLC conditions were as follows: C_(18)(4.6 mm?250mm,5?m) column,0.2% phosphoric acid—acetonitrile(96∶4) as mobile phase with flow rate of 1mL/min,and the detection wavelength at 205nm.(RESULTS:) The calibration curve of ephedrina hydrochloridum was linear between 0.448-3.416?g(r=(0.999 8,) n=7).The average recovery was 100.26% and RSD=2.17%(n=5).The calibration curve of pseudoephedrine hydrochloride was linear between 0.16-1.12?g(r= 0.999 1,n=7).The average recovery was 101.60% and RSD =2.19%(n=5). CONCLUSION: The method is convenient and efficient,and can be used for quantitative analysis and quality control of this preparation.
3.Determination of Puerarin in Huanglian Jiangtang Tablets by HPLC
Zhengyan XIA ; Ying FENG ; Shudan ZHANG
Traditional Chinese Drug Research & Clinical Pharmacology 2000;0(06):-
Objective To establish a method for the determination of Puerarin in Huanglian Jiangtang Tablets. Methods The sample was extracted with 30 %ethanol. The chromatographic conditions were as follows:Diamonsil C18 chromatographic column(250 mm?4.6 mm,5?m)with a mobile phase of acetonitrile-0.5 %glacial acetic acid,the detection wavelength being at 250 nm and the flow rate being 1.0 mL?min-1. Results A linearity was obtained from 0.338 ?g to 2.336 ?g of Puerarin in Huanglian Jiangtang Tablets with a good correlation (r=0.999997,n=7).The average recovery was 100.2% and RSD=1.80%(n=6). Conclusion This method for determination of Puerarin in Huanglian Jiangtang Tablets is easy,sensitive,specific and accurate.
4.Determination of Berberine Hydrochloride in Huanglian Jiangtang Pill by HPLC
Ying FENG ; Zhengyan XIA ; Jianming PAN
Traditional Chinese Drug Research & Clinical Pharmacology 1993;0(01):-
Objective To establish a method for the determination of berberine hydrochloride in Huanglian Jiangtang Pill. Methods The sample was extracted with hydrochloric acid-methanol(1 ∶ 100). The chromatographic conditions were as follows:Diamonsil C18 chromatographic column(250 mm? 4.6 mm,5 ? m)with a mobile phase of acetonitrile-0.05 mol/L potassium dihydrogen phosphate(28 ∶ 72),the detection wavelength at 350 nm and the flow rate being 1.0 mL? min-1. Results A good linearity was obtained from 0.244 ? g to 2.928 ? g of berberine hydrochloride in Huanglian Jiangtang Pill(r=0.999 9,n=7).The average recovery was 99.07 % and RSD=1.30 %(n=6). Conclusion This method is simple,sensitive,specific and accurate for determination of berberine hydrochloride in Huanglian Jiangtang Pill.
5.The effect of increased endometrial thickness on the outcome of in vitro fertilization and embryo transfer
Bencai TANG ; Shuhua LI ; Zhengyan HU ; Rong WANG ; Xia YANG
Chinese Journal of Primary Medicine and Pharmacy 2006;0(09):-
14mm.Results Group thick cycles had significantly lower implantation and pregnancy rates compared with group normal cycles(9.1% versus 13.5% and 18.8% versus 27.0%,respectively).Group thick cycles had significantly higher miscarriage rates compared with group normal cycles(50.0% versus 19.0%,respectively).Conclusion Increased endometrial thickness is associated with the decreased implantation or pregnancy rates and the increased miscarriage rates in IVF-ET.