1.Effects of GSRb3 on GABA in brain tissue of rats with injury of hypoxia
Hongmei SHEN ; Zhijun ZHANG ; Zhenglin JIANG
Journal of Clinical Neurology 1997;0(06):-
Objective To observe the influence of ginsenoside Rb3(GSRb3) on ?-aminobutyric acid (GABA) in brain tissue of rats with injury of hypoxia.Methods 20 rats were randomly divided into A, B, C, D and E group. The models of cerebral anoxia in group A and C were made by hypopiesia and hypoxia, and the models of hypoxia-reoxgenation were made in group B and D. 24 h and 1 h before establishment of models, ginsenoside Rb3 was injected peritoneally in rats of group C and D, respectively. The number and form of GABA-like immunoreactive neurons in hippocampus CA1 area of rats after brain hypoxia-reoxgenation were investigated with immunohistochemistry.Results (1)Compared with group E, GABA-like immunoreactive neuron density in CA1 area of group A and B decreased, presented with light staining and absence of prominency. GABA-like immunoreactive neuron density in CA1 area in group C and D was significantly higher than that in group A and B, but the shape was similar to group E. (2) The number of GABA-like immunoreactive neuron in CA1 area was 7.7?2.83 (group A), 10.1?2.08 (group B), 30.9?2.02 (group C), 33.1?4.2 (group D) and 16.9?1.05 (group E), respectively. The numbers were lower in group A and B than in group E, however higher in group C and D than in group E(all P
2.Combination of taurine and diazepam has neuroprotective effect on focal cerebral ischemia-reperfusion in rats
Guohua WANG ; Zhenglin JIANG ; Xia LI ; Xingjuan FAN ; Lihua SHEN
Chinese Journal of Pathophysiology 2010;26(4):737-741
AIM: To observe the neuroprotective effect of combined treatment with taurine and diazepam against focal cerebral ischemia-reperfusion in rats. METHODS: Sixty male Sprague-Dawley rats were randomly divided into five groups: sham-operation group, vehicle group, taurine group (200 mg/kg, ip), diazepam group (10 mg/kg, ip) and combined treatment group (taurine 100 mg/kg+diazepam 5 mg/kg). Focal cerebral ischemia was induced by the method of middle cerebral artery occlusion (MCAO) in rats, and reperfusion was emerged by removing the thread 2 h later. The drugs were administered respectively at the time of reperfusion, and subsequently repeated once 12 h later. The animals in vehicle group were intraperitoneally injected with isodose normal saline. The neurological deficit score, the brain water content and cerebral infarction were measured 48 h after MCAO. Other 5 group animals of focal cerebral ischemia-reperfusion (n=16 in each group) were set up as mentioned above and accepted treatments 10 h after reperfusion, likewise repeated once 12 h later. Twelve animals in each group were adopted the same management as the previous 5 groups at 48 h after MCAO. The remained 4 animals in each group were sacrificed until two weeks after MCAO to observe the histopathological changes by nissl staining. RESULTS: Compared to vehicle group, the animals in combined treatment group at 2 h or 12 h after MCAO both decreased the neurological deficit score, reduced the brain water content and infarct volume (P<0.01 or P<0.05). The combined treatment significantly alleviated the neurological necrosis as well. The neuroprotective effect of the combined treatment was superior to that of using taurine or diazepam alone. CONCLUSION: These results suggest that combination of taurine and diazepam treatment has a coordinate neuroprotective effect on both the acute and chronic brain damage of focal cerebral ischemia-reperfusion.
3.Application of rotational DSA dual volume technology in the displaying of intracranial artery stent and its effective analysis
Zhenglin SHEN ; Keqi HU ; Hongbin WEN ; Xiurong LI ; Liying CHANG
Journal of Practical Radiology 2016;32(10):1590-1593,1613
Objective To investigate the implementation and application of rotational DSA dual volume technology in displaying the intracranial artery stent.Methods Firstly,the “stent opacity”single volume technology was used to display 5 types of stent which were released in 7 cases of pure intracranial artery stenting and 12 cases of stent-assisted aneurysm embolization.Then we applied “vessel translucent”and “vessel opacity”single volume technology to display corresponding vessel segments.Finally,by coalescing the single volume imaging of stent and vessel,the “vessel opacity + stent opacity”dual volume image and “vessel translucent+ stent opacity”dual volume image were performed.We compared the effects of two kinds of dual volume imaging and assessed the imaging characteristics and influencing factors of each method.Results (1)On the “stent opacity”single volume display mode,in 7 cases of pure intracranial artery stenting,the display effect of two Pipeline stents and three Apollo stents belongs to level 1,the display effect of two Enterprise stents belongs to level 2;In 12 cases of stent-assisted aneurysm embolization,in the stent segments which weren’t influenced by artifacts,the display effect of two LEVIS stents belongs to level 1,the display effects of 5 Enterprise stents and 2 Solitaire AB stents belongs to level 2;While in the stent segments which were influenced by the artifact of spring coil and bone,the display effect significantly reduced, three pieces of Enterprise stents were even unable to identify.(2)On the “vessel opacity”single volume display mode,1 9 cases of vessel segment at the stent completed opacity display.The surface structure of vessel was very clear,but the structure under the surface was completely being covered.On the “vessel translucent”single volume display mode,the surface structure of 19 cases of vessel segment at the stent displayed clear at the tangential position.The vessel lumen also presented transparent state.(3)On the “stent opacity+vessels opacity”double volume display mode,the start-stop location and the adherence of stents in blood vessels in 1 6 cases were displayed clearly. When using the “stent opacity+ vascular opacity”double volume imaging,except 3 cases which used ball expansion Apollo stents could display comprehensive relationship between the blood vessels,in the other 13 cases,the relationship between stent and vascular could not be fully displayed.Conclusion On the condition that the single volume display technology shows stent well,the “stent opaque+vessels translucent”double volume display technology can well present the stent condition in the vessels.
4.Preliminary study of lateral cerebral angiography with reverse rotation in the digital image registration and subtraction
Zhenglin SHEN ; Dongyang LIU ; Zhenghai SHEN ; Shuping LI ; Ziyan ZHANG ; Yongjuan WU ; Peijun LIU
Chinese Journal of Radiology 2012;46(4):367-370
ObjectiveInvestigate the value and feasibility of image registration with reverse rotation in lateral cerebral DSA.Methods ( 1 ) Experimental study:the target images were subtracted directly,and subtracted again after reverse rotation.Software of registration and subtraction with reverse rotation edited by the author utilizing Visual Basic.The function of the automatic angle detection by the software were evaluated to see whether it detected the angle of line.The subtraction function of DSA by the software was evaluated.(2) Clinical retrospective study:the untreated mask and target inages of 15 patients with motion along vertical axis during lateral cerebral DSA were uploaded to the software.The target images were processed with and without the software to get two sets of images.( 3 ) Evaluation:four experienced radiologists read and compared the two sets of the images,and graded their findings.Results ( 1 ) The automatic detection by the software suggested that the target images should be rotated counterclockwise 1.3°. The subtraction result of the software was satisfactory.(2)In the 15 sets of images,there were only three sets of images deemed optimal after traditional subtraction.After reverse rotation,artifacts were significantly reduced and the image sharper. There were ten cases with significant artifacts after traditional subtraction,and those images were sharper and showed more peripheral vessels after reverse rotation. The traditional subtraction images of two sets could not be interpreted,the reverse rotation registration images reached the diagnostic quality.(3)Subjective evaluation: there were more information and less noise and distortion in the registration images with reverse rotation than in the traditional subtraction. But the image resolution decreased slightly after reverse rotation registration.ConclusionThe registration of digital angiography with reverse rotation can improve the image quality in lateral cerebral DSA.
5.Comparison of harvesting anterolateral thigh flap in medial and lateral approaches
Yonghui SHEN ; Dajiang SONG ; Xiao ZHOU ; Zan LI ; Zhenglin CHI ; Chunlin HOU
Journal of Chinese Physician 2017;19(5):671-674
Objective To investigate the results of defect reconstruction using anterolateral thigh free flap in medial and lateral approaches.Methods We reviewed the soft tissue defect reconstruction in 200 patients from February 2010 to June 2014 with anterolateral thigh flap in medial or lateral approach,to compare the operative time and donor site morbidity.Results The mean time of flap raising in medial group was (45 ± 4.5) minutes,while in lateral group was (65 ± 3.5) minutes.In medial group,fascial lata was closed directly in 39 cases (39%),while fascial lata was closed directly in all the cases (100%) in lateral group.All the 200 flaps survived uneventfully.All the donor sites healed smoothly.No infection occurred.An 8 to 32 months follow-up revealed a high satisfactory rate from the patients.No sensory deficit or functional impairment was noted in the donor sites.Conclusions Both in medial and lateral approach can achieve safely harvesting free anterolateral thigh flap.