1.Advances in the application of enhanced recovery after surgery in perioperative management of lung transplantation
Qiang FU ; Chunxiao HU ; Shuo ZHENG ; Pilai HUANG ; Xinzhong NING ; Qiang WU ; Jia HUANG ; Fulan CEN ; Peifen CHEN ; Jingyu CHEN ; Kun QIAO
Organ Transplantation 2025;16(6):976-982
Enhanced recovery after surgery (ERAS) is a series of perioperative optimization measures based on evidence-based medicine aimed at achieving rapid recovery. Existing studies have shown that ERAS can effectively reduce surgical stress, decrease the incidence of complications, shorten hospital stays, save medical costs, and improve patient satisfaction. Although lung transplantation techniques have become increasingly mature, lung transplant recipients still have a high incidence of complications during perioperative period. To further improve the perioperative survival rate of lung transplant recipients, introducing ERAS concept into the perioperative management strategy of lung transplantation is of great significance for reducing incidence of perioperative complications, promoting rapid recovery and long-term survival of lung transplant recipients. This article discusses the advances in application of ERAS concept in the perioperative management of lung transplantation, aiming to provide references for optimizing the perioperative management of lung transplant recipients and reducing perioperative complications.
2.Comparison of short-term clinical efficacy between CO external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures.
Min-Rui FU ; Chang-Long SHI ; Yong-Zhong CHENG ; Ming-Ming MA ; Zheng-Lin NIU ; Hai-Xiang SUN ; Jing-Hua GAO ; Zhong-Kai WU ; Yi-Ming XU
China Journal of Orthopaedics and Traumatology 2025;38(1):10-17
OBJECTIVE:
To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
METHODS:
Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.6±11.3) years old. Among them, there were 7 patients of traffic accidents and 18 patients of falls, resulting in a total of 25 patients of closed fractures and no open fractures, the treatment was conducted using closed reduction and CO external fixation. The internal fixation group consisted of 23 patients, comprising 8 males and 15 females, age ranged from 41 to 59 years old, with an average age of(53.3±13.7) years old. Among them, 8 patients resulted from car accidents while the remaining 15 patients were caused by falls. All 23 patients were closed fractures without any open fractures observed. The technique of open reduction and internal fixation with steel plate was employed. The perioperative data, including injury-operation time, operation duration, blood loss, and length of hospital stay, were assessed in both groups. Additionally, the QuickDASH score and visual analogue scale (VAS) were evaluated. Range of motion and grip strength assessment, imaging findings such as palmar inclination angle, ulnar declination angle, radius length, articular surface step, intra-articular space measurements were also examined along with any complications.
RESULTS:
The follow-up duration ranged from 0 to 24 months, with an average duration of (16.0±3.8) months. The CO external fixation exhibited significantly shorter time from injury to operation (2.4±3.3) d vs (7.4±3.7) d, shorter operation duration (56.27±15.23) min vs (74.10±5.26) min, lower blood loss (14.52±6.54) ml vs (32.32±10.03) ml, and reduced hospitalization days (14.04±3.24 )d vs (16.45±3.05) d compared to the internal fixation group (P<0.05). The QuickDASH score at 12 months post-operation was (8.21±1.64) in the CO external fixation group, while no significant difference was observed in the internal fixation group (7.04±3.64), P>0.05. There were no statistically significant differences in VAS between two groups at 6 weeks, as well as 1 and 3 months post-surgery (P>0.05). Additionally, there were no significant disparities observed in terms of range of motion and grip strength between two groups at the 2-year follow-up after the operation (P>0.05). After 12 months of surgery, the CO external fixation group exhibited a significantly smaller palmar inclination angle (17.90±2.18) ° vs (19.87±3.21) °, reduced articular surface step (0.11±0.03) mm vs (0.17±0.02) mm, and shorter radius length (8.16±1.11) mm compared to the internal fixation group (9.59±1.02) mm, P<0.05. The ulnar deviation angle and intra-articular space did not show any significant difference between two groups (P>0.05). The reduced fell within the allowable range between the CO external fixation group (23 out of 25 cases) and the internal fixation group (21 out of 23 cases) was not statistically significant (P=0.29). There was no significant difference in complications between the two groups(P>0.05).
CONCLUSION
Both the CO external fixation and open reduction with plate internal fixation demonstrate clinical efficacy in managing unstable distal radius fractures. The CO external fixation offers advantages in shorter injury-to-operation times, reduced intraoperative blood loss, and decreased surgical durations, while radial shortening is more effectively controlled by internal fixation.
Humans
;
Male
;
Female
;
Middle Aged
;
Radius Fractures/physiopathology*
;
Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
External Fixators
;
Retrospective Studies
;
Fracture Fixation/methods*
;
Wrist Fractures
3.Single-incision laparoscopic totally extraperitoneal retrieval of retroperitoneal vas deferens in vasovasostomy for obstructive azoospermia patients postchildhood bilateral herniorrhaphy.
Chen-Wang ZHANG ; Wei-Dong WU ; Jun-Wei XU ; Jing-Peng ZHAO ; Er-Lei ZHI ; Yu-Hua HUANG ; Chen-Cheng YAO ; Fu-Jun ZHAO ; Zheng LI ; Peng LI
Asian Journal of Andrology 2025;27(1):137-138
4.Delayed covering causes the accumulation of motile sperm, leading to overestimation of sperm concentration and motility with a Makler counting chamber.
Lin YU ; Qing-Yuan CHENG ; Ye-Lin JIA ; Yan ZHENG ; Ting-Ting YANG ; Ying-Bi WU ; Fu-Ping LI
Asian Journal of Andrology 2025;27(1):59-64
According to the World Health Organization (WHO) manual, sperm concentration should be measured using an improved Neubauer hemocytometer, while sperm motility should be measured by manual assessment. However, in China, thousands of laboratories do not use the improved Neubauer hemocytometer or method; instead, the Makler counting chamber is one of the most widely used chambers. To study sources of error that could impact the measurement of the apparent concentration and motility of sperm using the Makler counting chamber and to verify its accuracy for clinical application, 67 semen samples from patients attending the Department of Andrology, West China Second University Hospital, Sichuan University (Chengdu, China) between 13 September 2023 and 27 September 2023, were included. Compared with applying the cover glass immediately, delaying the application of the cover glass for 5 s, 10 s, and 30 s resulted in average increases in the sperm concentration of 30.3%, 74.1%, and 107.5%, respectively (all P < 0.0001) and in the progressive motility (PR) of 17.7%, 30.8%, and 39.6%, respectively (all P < 0.0001). However, when the semen specimens were fixed with formaldehyde, a delay in the application of the cover glass for 5 s, 10 s, and 30 s resulted in an average increase in the sperm concentration of 6.7%, 10.8%, and 14.6%, respectively, compared with immediate application of the cover glass. The accumulation of motile sperm due to delays in the application of the cover glass is a significant source of error with the Makler counting chamber and should be avoided.
Humans
;
Male
;
Sperm Motility/physiology*
;
Sperm Count
;
Semen Analysis/methods*
;
Spermatozoa/physiology*
;
Time Factors
6.Development of a smartphone-integrated handheld automated biochemical analyzer for point-of-care testing of urinary albumin.
Ze WU ; Peng ZHANG ; Wei XIAO ; Qian CHEN ; Wangrun LIN ; Peipei CHEN ; Kangwei CHEN ; Qiangqiang FU ; Zhijian WANG ; Lei ZHENG
Journal of Pharmaceutical Analysis 2025;15(3):101041-101041
The level of urinary albumin is a critical indicator for the early diagnosis and management of chronic kidney disease (CKD). However, existing methods for detecting albumin are not conducive to point-of-care testing due to the complexity of reagent addition and incubation processes. This study presents a smartphone-integrated handheld automated biochemical analyzer (sHABA) designed for point-of-care testing of urinary albumin. The sHABA features a pre-loaded, disposable reagent cassette with reagents for the albumin assay arranged in the order of their addition within a hose. The smartphone-integrated analyzer can drive the reagents following a preset program, to enable automatic sequential addition. The sHABA has a detection limit for albumin of 5.9 mg/L and a linear detection range from 7 to 450 mg/L. The consistency of albumin level detection in 931 urine samples using sHABA with clinical tests indicates good sensitivity (95.78%) and specificity (90.16%). This research advances the field by providing an automated detection method for albumin in a portable device, allowing even untrained individuals to monitor CKD in real time at the patient's bedside. In the context of promoting tiered diagnosis and treatment, the sHABA has the potential to become an essential tool for the early diagnosis and comprehensive management of CKD and other chronic conditions.
7.Development and application on a full process disease diagnosis and treatment assistance system based on generative artificial intelligence.
Wanjie YANG ; Hao FU ; Xiangfei MENG ; Changsong LI ; Ce YU ; Xinting ZHAO ; Weifeng LI ; Wei ZHAO ; Qi WU ; Zheng CHEN ; Chao CUI ; Song GAO ; Zhen WAN ; Jing HAN ; Weikang ZHAO ; Dong HAN ; Zhongzhuo JIANG ; Weirong XING ; Mou YANG ; Xuan MIAO ; Haibai SUN ; Zhiheng XING ; Junquan ZHANG ; Lixia SHI ; Li ZHANG
Chinese Critical Care Medicine 2025;37(5):477-483
The rapid development of artificial intelligence (AI), especially generative AI (GenAI), has already brought, and will continue to bring, revolutionary changes to our daily production and life, as well as create new opportunities and challenges for diagnostic and therapeutic practices in the medical field. Haihe Hospital of Tianjin University collaborates with the National Supercomputer Center in Tianjin, Tianjin University, and other institutions to carry out research in areas such as smart healthcare, smart services, and smart management. We have conducted research and development of a full-process disease diagnosis and treatment assistance system based on GenAI in the field of smart healthcare. The development of this project is of great significance. The first goal is to upgrade and transform the hospital's information center, organically integrate it with existing information systems, and provide the necessary computing power storage support for intelligent services within the hospital. We have implemented the localized deployment of three models: Tianhe "Tianyuan", WiNGPT, and DeepSeek. The second is to create a digital avatar of the chief physician/chief physician's voice and image by integrating multimodal intelligent interaction technology. With generative intelligence as the core, this solution provides patients with a visual medical interaction solution. The third is to achieve deep adaptation between generative intelligence and the entire process of patient medical treatment. In this project, we have developed assistant tools such as intelligent inquiry, intelligent diagnosis and recognition, intelligent treatment plan generation, and intelligent assisted medical record generation to improve the safety, quality, and efficiency of the diagnosis and treatment process. This study introduces the content of a full-process disease diagnosis and treatment assistance system, aiming to provide references and insights for the digital transformation of the healthcare industry.
Artificial Intelligence
;
Humans
;
Delivery of Health Care
;
Generative Artificial Intelligence
8.Development of a pretreatment workstation for detecting free silica levels in dust
Jian WU ; Yuqiao ZHENG ; Meng LUO ; Mengping ZHANG ; Junyi HUANG ; Fei SHEN ; Feng ZHANG ; Sheng FU ; Xuelei CHEN ; Zongli HUO ; Banghua WU
China Occupational Medicine 2025;52(4):455-459
Objective To investigate an automated pretreatment technology for detecting levels of free silica in workplace dust. Methods An fully automated pretreatment workstation for detecting free silica levels in workplace dust was developed by integrating graphite-controlled digestion temperature, online-controlled dilution of digestion solutions, and filtration endpoint recognition based on monitoring technology, combined with multi-channel synchronous measurements. Results The fully automatic pretreatment workstation was used to digest and filter 14 standard samples of free silica produced by three institutions, and then detected by pyrophosphate method. The result range of high-, medium-, and low-level free silica standard samples detection was 66.5%-84.8%, 40.0%-44.5%, and 2.1%-24.8%, respectively. The mean relative standard deviations were 3.9%, 1.4% and 1.5%. Conclusion The fully automated pretreatment workstation produced results that met relevant requirements. It can effectively replace the manual digestion and filtration steps of the pyrophosphate method to measure free silica levels in workplace dust and enable rapid detection of free silica in dust samples.
9.Comparison of growth characteristics of different genotypes of Japanese encephalitis virus in different cell lines
Weijia ZHANG ; Shenghui LIU ; Xiaohui YAO ; Yuke ZHENG ; Jiehui WU ; Ruichen WANG ; Shihong FU ; Qikai YIN ; Fan LI ; Kai NIE ; Qianqian CUI ; Songtao XU ; Huanyu WANG
Chinese Journal of Experimental and Clinical Virology 2024;38(1):15-20
Objective:To analyze the growth characteristics of different genotypes of Japanese encephalitis virus (JEV) in different cell lines, and to provide scientific basis for the selection of cell lines in the study of JEV.Methods:BHK-21, Vero, C6/36, PK-15, DF-1, N2a, SH-sy5y and MDCK cell lines were selected. The proliferation ability of genotype 1 (NX1889 strain), genotype 3 (P3 strain) and genotype 5 (XZ0934 strain) JEV in these cell lines was evaluated by plaque assay and RT-qPCR.Results:Significant cytopathogenic effects (CPE) were observed in BHK-21, Vero, C6/36, DF-1, N2a and PK-15 cell lines across all three JEV genotypes. However, no significant differences in CPE characteristics were observed within the same cell line. SH-sy5y and MDCK cell lines did not show significant CPE, but virus proliferation was detected in SH-sy5y cell line, while MDCK cell line were found to be insensitive to JEV. No significant difference was observed in the proliferation curves of G1, G3 and G5 JEV in BHK-21, Vero and SH-sy5y cell lines. In C6/36 and PK-15 cell lines, the titer of G1 JEV was higher than that of G3 and G5. In DF-1 cell line, G5 demonstrated a higher titer than the other two genotypes, whereas in N2a cell line, G5 showed a lower titer than the other two.Conclusions:There are differences in the proliferation of three different genotypes of JEV in different cell lines, which can provide reference for the study of JEV in different directions.
10.Preparation and characterization of methacryloylated hyaluronic acid/acellular Wharton's jelly composite hydrogel scaffold
Xun YUAN ; Zhengang DING ; Liwei FU ; Jiang WU ; Yazhe ZHENG ; Zhichao ZHANG ; Guangzhao TIAN ; Xiang SUI ; Shuyun LIU ; Quanyi GUO
Chinese Journal of Tissue Engineering Research 2024;28(22):3517-3523
BACKGROUND:As tissue engineering brings new hope to the worldwide problem of articular cartilage repair,the construction of light-curing 3D printed hydrogel scaffolds with biomimetic composition is of great significance for cartilage tissue engineering. OBJECTIVE:To construct a biomimetic methacryloylated hyaluronic acid/acellular Wharton's jelly composite hydrogel scaffold by digital light processing 3D printing technology,and to evaluate its biocompatibility. METHODS:Wharton's jelly was isolated and extracted from human umbilical cord,then decellulated,freeze-dried,ground into powder,and dissolved in PBS to prepare 50 g/L acellular Wharton's jelly solution.Methylallylated hyaluronic acid was prepared,lyophilized and dissolved in PBS to prepare 50 g/L methylallylated hyaluronic acid solution.Acellular Wharton's jelly solution was mixed with methacrylyacylated hyaluronic acid solution at a volume ratio of 1:1,and was used as bio-ink after adding photoinitiator.Methylacrylylated hyaluronic acid hydrogel scaffolds(labeled as HAMA hydrogel scaffolds)and methylacrylylated hyaluronic acid/acellular Wharton's jelly gel scaffolds(labeled as HAMA/WJ hydrogel scaffolds)were prepared by digital light processing 3D printing technology,and the microstructure,swelling performance,biocompatibility,and cartilage differentiation performance of the scaffolds were characterized. RESULTS AND CONCLUSION:(1)Under scanning electron microscope,the two groups of scaffolds showed a three-dimensional network structure,and the fiber connection of HAMA/WJ hydrogel scaffold was more uniform.Both groups achieved swelling equilibrium within 10 hours,and the equilibrium swelling ratio of HAMA/WJ hydrogel scaffold was lower than that of HAMA hydrogel scaffold(P<0.05).(2)CCK-8 assay showed that HAMA/WJ hydrogel scaffold could promote the proliferation of bone marrow mesenchymal stem cells compared with HAMA hydrogel scaffold.Dead/live staining showed that bone marrow mesenchymal stem cells grew well on the two groups of scaffolds,and the cells on the HAMA/WJ hydrogel scaffolds were evenly distributed and more cells were found.Phalloidine staining showed better adhesion and spread of bone marrow mesenchymal stem cells in HAMA/WJ hydrogel scaffold than in HAMA.(3)Bone marrow mesenchymal stem cells were inoculated into the two groups for chondrogenic induction culture.The results of qRT-PCR showed that the mRNA expressions of agglutinoglycan,SOX9 and type Ⅱ collagen in the HAMA/WJ hydrogel scaffold group were higher than those in the HAMA hydrogel scaffold group(P<0.05,P<0.01).(4)These findings indicate that the digital light processing 3D bioprinting HAMA/WJ hydrogel scaffold can promote the proliferation,adhesion,and chondrogenic differentiation of bone marrow mesenchymal stem cells.

Result Analysis
Print
Save
E-mail