2.Clinical study of the effect of cardiac resynchronization therapy in patients of chronic heart failure
Xi SU ; Zhen LI ; Hongwei HAN
Chinese Journal of Interventional Cardiology 1996;0(04):-
Objective To investigate the effect of cardiac resynchronization therapy on improving heart function and reversing left ventricular remodeling in chronic heart failure patients. Methods Eleven patients with NYHA class Ⅲ to Ⅳ heart failure, ejection fraction ≤35% and QRS duration ≥130 ms were implanted synchronous biventricular pacemaker. Serial assessment was performed before and up to 1-36 months after pacing. Results There were significant improvement of LVEF、 LVFS; and decrease in MR、 LVED and QRS duration. The NYHA class of heart function was improved from Ⅲ-Ⅳ to Ⅰ-Ⅱ. Six-minute hall walk distances were also improved. Conclusion For patients with NYHA class Ⅲ to Ⅳ heart failure and ventricular conduction delay, cardiac resynchronization therapy could reverse left ventricular remodeling and improve heart function.
4.Influence of Pulmonary Hypertension Induced by Left-to-Right Shunt on Pulmonary Collagen Remodeling
zhen-hui, HAN ; xi, ZHANG ; zhen-yu, XIONG ; yong, GAI
Journal of Applied Clinical Pediatrics 2004;0(12):-
Objective To establish a rat model of pulmonary hypertension induced by left-to-right shunt and explore the influence of high pulmonary blood flow on pulmonary vascular collagen remodeling.Methods Abdominal aorta and inferior vena cava shunting was produced in rats. Pulmonary artery meanpressure (PAMP) of each rat was measured by using a right cardiac catheterization.Pulmonary artery collagen Ⅰ and Ⅲ were detected using immunohistochemisty.Results After 11 weeks of shunting the Qp/Qs was 3.3∶1.0,indicating a large shunt. Pulmonary artery mean pressure was increased as compared with controls[(23.0?0.9) mm Hg vs (15.7? 1.1) mm Hg,P
6.Encephalic lymphomatoid granulomatosis.
Li YU ; Zhen-Xi LIU ; Sha XIAO ; Cheng-Yi LUO
Chinese Journal of Pathology 2005;34(2):121-122
8.Comparison of surgical efficacies of transurethal enucleation of prostate with transurethal resection of prostate
Zhen HUANG ; Mengjie ZHAO ; Shaoming LIU ; Jinbo XI
Clinical Medicine of China 2013;29(9):984-986
Objective To compare the surgical effects of transurethal enucleation of prostate (TUEP)with transurethal resection of prostate (TURP) by a retrospective analysis of clinical data.Methods The patients in this study were divided into the groups of TUEP (enrolled in 2010 and 2011,n =77) and TURP (enrolled in 2009,n =27) with prostate larger than 60 g and smaller than 60 g respectively.Comparisons were made between the two groups in operation time,blood loss volume and weight of resected prostate.Results In the group of patients with prostate larger than 60 g,there was no significant difference in prostate weight ((88.5 ± 9.2) g vs.(107.0 ± 15.30) g,P =0.255),operation time ((91.5 ± 8.8) min vs.(118.3 ± 20.2)min,P =0.083),and weight of resected prostate ((48.0 ± 4.6) g vs.(58.4 ± 5.4) g,P =0.32) between the TUEP (53 patients) and the TURP (12 patients) groups.There was significant difference in blood loss ((110.0 ± 16.4) ml vs.(193.3 ± 22.3) ml,P =0.011) between the two groups.In the group of patients with prostate smaller than 60 g,there was no significant difference in prostate weight ((43.1 ± 3.2) g vs.(36.8 ± 3.4) g,P =0.072),operation time ((62.7 ±6.8) min vs.(69.3 ±6.2) min,P =0.431),blood loss ((56 ± 5) ml vs.(110±20) ml,P=0.082),and weight of resected prostate ((26.3 ±2.4) g vs.(23.6 ±2.1) g,P =0.291) between the TUEP (24 patients) and the TURP (15 patients) groups.Conclusion Compared with TURP,TUEP has the advantages of less blood loss in the treatment of patients with prostate larger than 60 g.With the improvement of surgeon' s experience and development of operation techniques,TURP will be replaced by TUEP.In the treatment of patients with prostate smaller than 60 g,the operation modality can be chosen by the surgeon based on his experience and proficiency.
9.Analysis of self-efficacy and its influencing factors in adult patients with low vision
Yu ZENG ; Shuxin XI ; Yanmei ZHU ; Zhen YANG ; Jing SUN
Chinese Journal of Practical Nursing 2013;29(19):51-53
Objective To evaluate the status of self-efficacy and its influencing factors in adult patients with low vision,then explore an effective approach to improve their self-efficacy levels.Methods Seventy adult patients with low vision were sampled by random number table method.General social-demographic questionnaire and self-efficacy questionnaire were used to investigate these patients' general information and self-efficacy.Seventy pieces of questionnaires were issued and returned with the valid rate of 100%.Results The total score of self-efficacy in seventy adult patients with low vision was(16.25:±:1.93) points,92% of patients had a low level of self-efficacy.The influencing factors of self-efficacy in adult patients with low vision were the attitude toward disease,mental status and gender.Conclusions The selfefficacy in patients with low vision was affected by many factors at different levels,so we should focus on main influencing factors to adopt corresponding nursing measures in order to improve self-efficacy of adult patients with low vision.
10.Preparation and Application of Naringin Sensor Based on Molecularly Imprinting Technique
Xiuling MA ; Riyao CHEN ; Xi ZHENG ; Xiao CHEN ; Zhen CHEN
Chinese Journal of Analytical Chemistry 2010;38(1):100-104
The sensor of naringin(NG), a non-electroactive substance, was prepared based on the molecular imprinting technique.Using cyclic voltammetry technique (scan rate is 100 mV/s), the naringin imprinting sensitive film, poly-o-aminophenol was coated on the surface of a graphite electrode in the presence of naringin which was considered as the template, and characterized by SEM and X-ray reflective spectrophotometry (XRR).Using K_3Fe(CN)_6 as an electroactive marker, the electrochemical properties of the NG sensor were investigated by CV, electrochemical impedance spectroscopy (EIS), differential pulse voltammmetric and chronoamperometric.The results showed that the imprinted electrode was significantly different from the non imprinted electrode in morphologies and electrochemical properties, and a linear relationship between the peak current and the naringin concentration was found in the range of 6.0 × 10 ~(-5)-1.4 × 10 ~(-4) mol/L with a detec tion limit of 1.6 × 10 ~(-5) mol/L.Moreover, the imprinted electrode exhibited a good selectivity and rapid response to the naringin template molecules, as well as an excellent reproducibility(RSD = 1.8 %, n=5).