1.Design of a testing system for antithrombotic pressure circulatory equipment.
Xun ZHOU ; Haipo CUI ; Kun SHANG ; Zhelong LI ; Enqing CHENG
Journal of Biomedical Engineering 2014;31(1):192-195
A new type of testing system used for antithrombotic pressure circulatory equipment has been developed, which realized a new method for the calibration of pressure sensor. Multi-path control and acquisition functions are achieved by this method based on human-computer interaction testing system. The precision of pressure sensor is ob tained by polynomial fitting for each test point using linear interpolation method. The result showed that the precision test of pressure sensor could be realized easily and efficiently, using the developed testing system, and the parameters of pressure sensor could be calibrated effectively, so that it could be accurately used in the antithrombotic pressure circulatory equipment. The developed testing system has a prosperous future in the aspects of promotion and application.
Algorithms
;
Calibration
;
Equipment Design
;
Humans
;
Monitoring, Physiologic
;
instrumentation
;
Pressure
;
Thrombosis
;
diagnosis
2.Testing system design and analysis for the execution units of anti-thrombotic device.
Zhelong LI ; Haipo CUI ; Kun SHANG ; Yuehua LIAO ; Xun ZHOU
Journal of Biomedical Engineering 2015;32(1):187-191
In an anti-thrombotic pressure circulatory device, relays and solenoid valves serve as core execution units. Thus the therapeutic efficacy and patient safety of the device will directly depend on their performance. A new type of testing system for relays and solenoid valves used in the anti-thrombotic device has been developed, which can test action response time and fatigue performance of relay and solenoid valve. PC, data acquisition card and test platform are used in this testing system based on human-computer interaction testing modules. The testing objectives are realized by using the virtual instrument technology, the high-speed data acquisition technology and reasonable software design. The two sets of the system made by relay and solenoid valve are tested. The results proved the universality and reliability of the testing system so that these relays and solenoid valves could be accurately used in the antithrombotic pressure circulatory equipment. The newly-developed testing system has a bright future in the aspects of promotion and application prospect.
Equipment Design
;
Humans
;
Monitoring, Ambulatory
;
instrumentation
;
Pressure
;
Reproducibility of Results
;
Software
;
Thrombosis
;
diagnosis
3.Establishment of cyclophosphamide-induced cardiotoxicity mouse model and ultrasound evaluation
Guangli HOU ; Lijun YUAN ; Ruijing SHI ; Lianbi ZHAO ; Zhelong LI
Chinese Journal of Ultrasonography 2017;26(11):1001-1004
Objective To analyze the dose dependent cardiotoxicity of cyclophosphamide and thus establish the mouse models for understanding the underlying mechanisms . Methods Thirty mice ( 7 -8 weeks old) were randomly divided into 6 groups:control of one course group ,control of two courses group , one course of low dose ( 50 mg/kg) group ,two courses of low dose group ,one course of high dose ( 100 mg/kg) group ,two courses of high dose group . The changes of cardiac function and morphology were analyzed at indicated times by ultrasound and histology respectively . Results Compared with the control groups , injection of low dose cyclophosphamide either with one course or two courses ,and injection of high dose with only one course had no in statically significant changes in hair color ,physical activity ,body weight and cardiac function( P > 0 .05) . Treatment of two courses with high dose resulted in significant decrease of physical activity and body weight ( P < 0 .05 ) . Meanwhile ,cardiac systolic function was significantly decreased( P <0 .05) . Histology study revealed robust cardiac hypertrophy and fibrosis . Conclusions Two courses of intraperitoneal injection of cyclophosphamide at high dose result in obvious cardiotoxicity , especially systolic dysfunction .Intraperitoneal injection of two courses of cyclophosphamide serves as a good strategy to induce cardiotoxicity in mice ,which could be applied for future mechanism study .
4.Internal audit of Organ Procurement Organization under the requirements of high-quality development
Shunliang YANG ; Lizhi LYU ; Zhelong JIANG ; Yushu LI ; Dong WANG ; Zaixin WU
Organ Transplantation 2023;14(4):485-
High-quality development is the primary task of building a socialist modern country in an all-round way. Organ donation and transplantation in China are evolving from high-speed growth to high-quality development, which put forward new requirements for the safe, stable and healthy operation of Organ Procurement Organization (OPO). Safety is the foundation and prerequisite for achieving the goal of high-quality development. As an independent and comprehensive department, internal audit should create new achievements in the new era. The department should include OPO and organ donation into the scope of internal audit, shift the emphasis upon the overall development of organ donation. Besides, it should fully consider the actual situation in different places, conduct all-round, objective and fair evaluation, provide evaluation and consulting services for OPO to properly implement organ donation, and give full play to the supervision and prevention role of internal audit.
5.The question of death criteria in human organ donation
Shunliang YANG ; Zhelong JIANG ; Lizhi LYU ; Yushu LI ; Dong WANG
Organ Transplantation 2024;15(3):359-366
Donation after death is the most important ethical principle to carry out organ donation after citizens’ death. The newly-revised Regulations on Human Organ Donation and Transplantation does not define death, and avoids the key question of “whether to recognize brain death”. Certain legal risks or damages to the rights and interests of donors may exist in organ donation. Death is an inevitable part of human life. It is necessary to establish specific criteria, which is also the only approach, to define death in any era. Death criteria are established based on the view of death, and restricted by the development level of productive forces and other social factors. The determination of death criteria hugely varies between China and the West. To standardize organ donation and transplantation and promote high-quality development of organ donation, medical staff must adhere to the principle of pure motivation, take informed consents as the premise, respect the donors' and their close relatives' rights to choose their own death criteria, strictly follow the death judgment procedures and operating norms, and ensure the scientificity, accuracy and fairness of death determination.