1.EXPERIMENTAL STUDY OF HELICAL CT COLONOSCOPY
Zhaoying WEN ; Wanshi ZHANG ; Dong WANG
Medical Journal of Chinese People's Liberation Army 2001;0(08):-
To explore diagnostic acuity of helical CT colonscopic examination, simulated polyps were reproduced in 10 pig colons and 6 human colons obtained from colon resection. Helical CT colonoscopic scanning with different parameters was performed. The images were evaluated with Nav, Axial+MPR, SSD+Raysum. The diagnostic sensitivity of each method for the detection of simulated colonic polyps were assessed. The results indicated that the image quality of CT colonoscopy was improved with the decrease in collimation and pitch. The optimal angle of the colon lumen to the gantry was 90?. CT colonoscopy was superior to other imaging methods. Therefore, the performance of CTVC has a close relationship with the scanning parameters. The optimal scanning parameters were 5mm collimation, 1 5 pitch, and filling the colon with air. The combination of CTVC with other imaging methods would contribute to improving the diagnostic accuracy for the detection of colonic polyps.
2.Left atrial volume and function evaluation by dual source CT:a comparison with real-time three-dimensional echocardiography(RT-3DE)
Zhaoying WEN ; Ying ZHAO ; Xingmei ZHANG ; Wei YU ; Zhaoqi ZHANG
Medical Journal of Chinese People's Liberation Army 1981;0(06):-
0.05). The interobserver variability in DSCT measurements was lower than in RT-3DE measurements in indexed left atrial volume and function. Conclusion DSCT can provide not only the information of coronary artery,but also highly reliable measurements of left atrial phasic volume and function at the same time.
3.Therapeutic Observation of Hair Needle Therapy for Dry Eye Syndrome
Deyu ZHANG ; Yanfei XING ; Xiaoli SONG ; Zhaoying WANG
Shanghai Journal of Acupuncture and Moxibustion 2015;(12):1195-1197
ObjectiveTo observe the clinical efficacy of hair needle therapy in treating dry eye syndrome (DES).Method Eighty patients diagnosed with DES were randomized into a treatment group and a control group, 40 cases in each group. The treatment group was intervened by 0.1% Sodium Hyaluronate eye drops plus Hair needle therapy; the control group was by 0.1%Sodium Hyaluronate eye drops alone. The subjects were re-examined after 1-month treatment. The therapeutic efficacy was evaluated by observing the subjective symptoms, SchirmerⅠtest (SIT), tear break-up time (BUT), and fluorescein test (FL).Result The subjective symptoms, SIT, BUT, and FL scores were significantly improved after intervention in the treatment group (P<0.05);the control group only had the subjective symptoms improved after intervention (P<0.05), while other indexes didn’t show significant differences (P>0.05); after treatment, there were significant differences in comparing the subjective symptoms, SIT, BUT, and FL scores between the two groups (P<0.01).ConclusionHair needle therapy plus Sodium Hyaluronate eye drops can produce a more significant efficacy than Sodium Hyaluronate eye drops alone in treating DES.
4.Effect of Pentoxifylline on type 1 diabetes in NOD mice
Junhua HE ; Lizhen LAN ; Zhili ZHANG ; Zhaoying LI
Chinese Journal of Endocrinology and Metabolism 2001;0(05):-
Objective To study the effect of phosphodiesterase inhibitor pentoxifylline (PTX) on type 1 diabetes in NOD mice and its possible mechanism.Methods Blood glucose, urinary glucose, insulitis and incidence of diabetes were investigated in NOD mice treated with PTX, insulitis was observed by HE staining and the expressions of IFN ?, TNF ?, IL 10 in pancreas were measured by RT PCR technique. Results The incidence of diabetes in the PTX group was 30.0% which was significantly lower than 67.9% in the control group (P
5.Efficacy Observation of Polyene Phosphatidyl Choline Combined with Hugan Tablets in the Treatment of Drug-induced Liver Injury
Dongping ZHANG ; Zhaoying XIAO ; Aifeng WU ; Yan SHAO
China Pharmacist 2014;(9):1524-1525,1528
Objective:To observe the efficacy of polyene phosphatidyl choline combined with Hugan tablets in the treatment of drug-induced liver injury. Methods:Totally 80 cases of drug-induced liver injury were randomly divided into the observation group (40 cases )and the control group(40 cases). The observation group was given polyene phosphatidyl choline injections 697. 5mg+5%glucose injections 250ml,ivd,qd,combined with Hugan tablets 1. 44g,po,tid,the control group was given polyene phosphatidyl choline injections 697. 5mg+5%glucose injections 250ml,ivd,qd,and the symptomatic treatment in the two groups was the same. The two groups were treated for 20d. Alanine aminotransferase ( ALT), aspartate aminotransferase ( AST), total bilirubin ( TBIL), glutamyl transpeptidase(GGT) and alkaline phosphatase(ALP)were detected respectively before and after the treatment, and the therapeutic effects were compared between the two groups. Results: After the treatment,the total effective rate in the observation group was 97. 5%,which was significantly higher than that in the control group(P <0. 01),Symptoms,signs and biochemical indices in the two groups were improved obviously. The decrease of ALT,AST and GGT in the observation group after the treatment was obviously lower than that in the control group(P<0. 05). Conclusion: Polyene phosphatidylcholine injections combined with Hugan tablets in the treatment of liver injury is better than polyene phosphatidyl choline, which is worthy of clinical application.
6.Assessment of left atrial volume and function with dual-source CT: comparison with 3.0 T MRI
Zhaoying WEN ; Zhaoqi ZHANG ; Wei YU ; Zhanming FAN ; Jing DU ; Biao LU
Chinese Journal of Radiology 2011;45(12):1122-1126
ObjectiveTo assess the performance of dual-source CT (DSCT) for left atrial volume and function evaluation and compare this performance to that of cardiac cine MR ( CMR ),which was considered as the standard reference technique.Methods Forty-nine patients referred for CT coronary angiography were enrolled in this study.DSCT data sets and FIESTA cines of the vertical long axis covering the left atrium and the short axis covering the left ventricle were obtained on the same day without additional medicine.All images were analyzed to obtain left atrial volume at different time and its function values.All the parameters were corrected by body surface area.Inter-modality agreement was tested through linear regression and Bland-Altman analyses.Repeated measurements were performed to determine inter-observer variation.ResultsThe indexed measurements of DSCT and CMR were (47.4 ± 11.1 ) and (46.2 ± 9.7 )ml/m2 for LAVmax,( 22.2 ± 6.9) and ( 21.3 ± 5.8 ) ml/m2 for LAVmin,( 34.8 ± 8.8 ) and ( 33.6 ± 7.8 )ml/m2 for LAVp,(24.0 ±5.7)and(21.5 ±5.0) ml/m2 for LARV,(11.6 ±3.9)and(10.9 ±3.9) ml/m2 for LAPV,(12.4 ±3.9)and(10.7 ±3.6) ml/m2 for LAAV,(22.6 ±8.4)and(21.0 ±6.4) ml/m2 for LACV,(52.8 ± 7.4) % and ( 54.5 ± 6.3 ) % for LAEF,respectively.The correlation coefficients between DSCT and CMR measurements for LAVmax,LAVmin,LAVp,LARV,LAPV,LAAV,LACV and LAEF were 0.89,0.90,0.90,0.80,0.82,0.80,0.76 and 0.78,respectively.However,DSCT slightly overestimated LAVmax,LAVmin,LAVp,LARV,LAPV,LAAV and LACV,and the deviation was 1.2,0.9,1.1,0.3,0.1,0.2 and 0.4 ml/m2,respectively.Compared with CMR,DSCT slightly underestimated LAEF of about 0.6%.Interobserver variation was lower in DSCT examination than CMR for the measurements of left atrial function.ConclusionDSCT provided accurateand reproducible measurements of left atrial volume and function.
7.Application and overview of image guided surgery system.
Wenkui SU ; Yuli ZHANG ; Dongmei LI ; Zhaoying ZHOU
Chinese Journal of Medical Instrumentation 2010;34(4):284-288
This paper introduces the development and the key technology of image guided Surgery Systems (IGSS) and analyses its prospect in this paper. IGSS can be used in clinical surgery as an assistant tool, and it would be an advanced medical equipment combined with medical robotics.
Robotics
;
Surgery, Computer-Assisted
;
instrumentation
;
methods
8.Robust low-dose CT myocardial perfusion deconvolution via high-dimension total variation regularization.
Changfei GONG ; Dong ZENG ; Zhaoying BIAN ; Hua ZHANG ; Zhang ZHANG ; Jing ZHANG ; Jing HUANG ; Jianhua MA
Journal of Southern Medical University 2015;35(11):1579-1585
OBJECTIVETo develop a computed tomography myocardial perfusion (CT-MP) deconvolution algorithm by incorporating high-dimension total variation (HDTV) regularization.
METHODSA perfusion deconvolution model was formulated for the low-dose CT-MPI data, followed by HDTV regularization to regularize the consistency of the solution by fusing the spatial correlation of the vascular structure and the temporal continuation of the blood flow signal.
RESULTSBoth qualitative and quantitative studies were conducted using XCAT and pig myocardial perfusion data to evaluate the present algorithm. The experimental results showed that this algorithm achieved hemodynamic parameter maps with better performances than the existing methods in terms of streak-artifacts suppression, noise-resolution tradeoff, and diagnosis structure preservation.
CONCLUSIONThe proposed algorithm can achieve high-quality hemodynamic parameter maps in low-dose CT-MPI.
Algorithms ; Animals ; Artifacts ; Models, Theoretical ; Phantoms, Imaging ; Swine ; Tomography, X-Ray Computed
9.Edge-detecting operator-based selection of Huber regularization threshold for low-dose computed tomography imaging.
Shanli ZHANG ; Hua ZHANG ; Debin HU ; Dong ZENG ; Zhaoying BIAN ; Lijun LU ; Jianhua MA ; Jing HUANG
Journal of Southern Medical University 2015;35(3):375-379
OBJECTIVETo compare two methods for threshold selection in Huber regularization for low-dose computed tomography imaging.
METHODSHuber regularization-based iterative reconstruction (IR) approach was adopted for low-dose CT image reconstruction and the threshold of Huber regularization was selected based on global versus local edge-detecting operators.
RESULTSThe experimental results on the simulation data demonstrated that both of the two threshold selection methods in Huber regularization could yield remarkable gains in terms of noise suppression and artifact removal.
CONCLUSIONBoth of the two methods for threshold selection in Huber regularization can yield high-quality images in low-dose CT image iterative reconstruction.
Artifacts ; Humans ; Image Processing, Computer-Assisted ; Tomography, X-Ray Computed
10.Low-dose CT angiography image restoration using normal dose scan-induced non-local means algorithm.
Yunwan ZHANG ; Yang LIU ; Jing HUANG ; Dong ZENG ; Zhaoying BIAN ; Hua ZHANG ; Jianhua MA
Journal of Southern Medical University 2013;33(9):1299-1303
OBJECTIVETo minimize of the radiation dose of cardiovascular CT angiography (CTA) imaging while preserving the image quality.
METHODSTo reduce the radiation dose in CTA imaging, the normal-dose scan induced non-local means (ndiNLM) algorithm was adapted for low-mAs scanned CTA image restoration by using the previous scanned high-quality image.
RESULTSQualitative and quantitative evaluations were carried out on both simulated phantom and clinical CTA scans in terms of accuracy and resolution properties. Compared to the original NLM algorithm, the ndiNLM method could achieve noticeable gains in terms of noise-induced artifacts suppression and enhanced structure preservation.
CONCLUSIONThe ndiNLM algorithm is a potential useful technique to reduce the radiation dose in CTA imaging.
Algorithms ; Coronary Angiography ; Humans ; Image Processing, Computer-Assisted ; methods ; Models, Statistical ; Radiation Dosage ; Tomography, X-Ray Computed