1.Cytocompatibility of nano-hydroxyapatite/bacterial cellulose nanocomposites and its residues
Qi ZHENG ; Tingfei XI ; Yanmei CHEN ; Zhaoxu WANG ; Yizao WAN ; Chuan GAO
Chinese Journal of Tissue Engineering Research 2010;14(3):405-409
BACKGROUND: The nano-hydroxyapatite/bacterial cellulose (nHAP/BC) nanocomposites has a good prospect of application in bone tissue engineering, and the bone tissue engineered materials and its degradation products Should have excellent compatibility. This study further assessed DAN synthesis cycle using flow cytometry on the basis of evaluating cell compatibility by metabolic 3-(4, 5-dim ethylthiazo 1-2-y 1) -2, 5-Dipheny 1-2H-tetrazolium (MTT) assay. OBJECTIVE: To evaluate the cytocompatibility of a new-pattern nHAP/BC nanocomposites and its residues. METHODS: Effects of nHAP/BC nanocomposites and its residues on morphclogicel changes in osteoblasts were observed using in vitro cell culture method. Effects of nHAP/BC nanocomposites and its residues on osteoblast growth and prclifera'don were evaluated by MTT assay. Cell cycle phase changes were detected using flow cytometry to evaluate matsdal effects on cell proliferation on molecular levels. RESULTS AND CONCLUSION: The nHAP/BC nanocomposites and its residues had neither remarkable effects on cell morphology, nor significant inhibition on osteoblast growth and proliferation. Test of MTT cytotoxicity showed that the average cell proliferation rate was over 80% after treated with the material and its residues, with the cytotoxity grade of 1 (non-toxic). Flow cytometry indicated that the rate of G_0/G_1 was reduced, and the rates of S, G2/M were increased, and the synthesis of DNA was increased, the cellular growth and repair in osteoblasts was accelerated. These indicated that nHAP/BC nanocomposites have good cytocompatibility, and it will be safe and prospected scaffolds in bone tissue engineering.
2.In vivo safety of self-filling osmotic tissue expander
Chuanwei SUN ; Zhaoxu WANG ; Huade CHEN ; Shaoyi ZHENG ; Huining BIAN ; Wen LAI
Chinese Journal of Tissue Engineering Research 2013;(51):8881-8886
BACKGROUND:The osmotic tissue expander is a self-fil ing device consisting of an osmotic active hydrogel which is made of vinylpyrrolidone and mehtylmethacrylate. It can absorb body fluids and swel up gradual y after embedded.
OBJECTIVE:To explore the short-term and long-term regular patterns as wel as histocompatibility of the osmotic tissue expander in vivo.
METHODS:A self-control design was carried out in Wistar rats by embedding the osmotic tissue expander and high-density polyethylene into each side of their spinal column subcutaneously. Wound healing, tissue expansion and inflammatory reaction were detected and compared at different periods after operation.
RESULTS AND CONCLUSION:Al the wounds got primary healing. The device expanded fastest at week 1 after the implantation. After being enlarged to about nine times that of the initial size at week 4, the expander slowed down its swel ing. It reached its ultimate volume at week 12 which was about 10 times as big as that of the initial one. Then it remained almost the same size until the end of our design. Pathological sections showed that the inflammatory reaction of osmotic-tissue-expander-group had no significant difference from that of the control group (P>0.05). These findings suggest that osmotic tissue expander has a slow-lasting swel ing ability and good histocompatibility.
3.A biomechanical comparison of conventional versus an anatomic plate and compression bolts for fixation of intra-articular calcaneal fractures.
Haili, WANG ; Zhaoxu, YANG ; Zhanpo, WU ; Wei, CHEN ; Qi, ZHANG ; Ming, LI ; Zhiyong, LI ; Yingze, ZHANG
Journal of Huazhong University of Science and Technology (Medical Sciences) 2012;32(4):571-5
The purpose of this study was to compare the biomechanical stability obtained by using our technique featured an anatomical plate and compression bolts versus that of the conventional anatomic plate and cancellous screws in the fixation of intraarticular calcaneal fractures. Eighteen fresh frozen lower limbs of cadavers were used to create a reproductive Sanders type-III calcaneal fracture model by using osteotomy. The calcaneus fractures were randomly selected to be fixed either using our anatomical plate and compression bolts or conventional anatomic plate and cancellous screws. Reduction of fracture was evaluated through X radiographs. Each calcaneus was successively loaded at a frequency of 1 Hz for 1000 cycles through the talus using an increasing axial force 20 N to 200 N and 20 N to 700 N, representing the partial weight bearing and full weight bearing, respectively, and then the specimens were loaded to failure. Data extracted from the mechanical testing machine were recorded and used to test for difference in the results with the Wilcoxon signed rank test. No significant difference was found between our fixation technique and conventional technique in displacement during 20-200 N cyclic loading (P=0.06), while the anatomical plate and compression bolts showed a great lower irreversible deformation during 20-700 N cyclic loading (P=0.008). The load achieved at loss of fixation of the constructs for the two groups had significant difference: anatomic plate and compression bolts at 3839.6±152.4 N and anatomic plate and cancellous screws at 3087.3±58.9 N (P=0.008). There was no significant difference between the ultimate displacements. Our technique featured anatomical plate and compression bolts for calcaneus fracture fixation was demonstrated to provide biomechanical stability as good as or better than the conventional anatomic plate and cancellous screws under the axial loading. The study supports the mechanical viability of using our plate and compression bolts for the fixation of calcaneal fracture.
4. Differences in Microsatellite Instability, K-ras Gene Mutation and Other Clinicopathological Features Between Left and Right Hemicolon Cancer
Chinese Journal of Gastroenterology 2019;24(7):400-405
Background: Colon cancer is one of the most common malignant tumor of digestive system. There are differences in pathogenesis, biological behavior, gene expression between left and right hemicolon cancer. Aims: To investigate the differences in clinicopathological features, microsatellite instability (MSI) and K-ras gene mutation between left and right hemicolon cancer. Methods: Data of 144 patients with colon cancer diagnosed by postoperative pathology from June 2017 to June 2018 at Qingdao Municipal Hospital were collected. MSI was assessed by immunohistochemistry, K-ras gene mutation was detected by PCR. The differences in clinicopathological features, MSI and K-ras gene mutation between the two groups were compared. Results: Right hemicolon cancer was more common in female, and left hemicolon cancer was more common in male. The incidence of lymph node metastasis, positivity rate of CEA and MSI in right hemicolon cancer were significantly higher than left hemicolon cancer (P<0.01), while the K-ras gene mutation rate in left hemicolon cancer was significantly higher than right hemicolon cancer (P<0.05). The K-ras gene mutation in left hemicolon cancer was correlated with gender, lymph node metastasis and positivity rate of CEA (P<0.05). MSI in right hemicolon cancer was correlated with gender, age, and lymph node metastasis (P<0.05). Conclusions: There are differences in the MSI and K-ras gene mutation between left hemicolon cancer and right hemicolon cancer, which can be used as the reference for diagnosis, individualized treatment and prognosis of colon cancer.
5.Effects of grasp seed procyanidins on homocysteine-induced proliferation and migration in vascular smooth muscle cells
Weizhen XUE ; Jiliang WANG ; Zhaoxu MAO ; Zhimin XU ; Xiaoping CHEN ; Zhenti DANG ; Jie REN ; Dengfeng MA ; Yingjie TAI ; Yigang HE
Chinese Journal of Pathophysiology 1986;0(02):-
AIM:To investigate the effects of grasp seed procyanidins(GSP) on homocysteine-induced proliferation and migration in vascular smooth muscle cells(VSMC) and related molecular mechanisms.METHODS: Cell count and -TdR assay were used for detecting cell proliferation and DNA synthesis,ELISA assay was used for detecting inflammatory response,DCFH-DA assay for examining the levels of reactive oxygen species(ROS),Western blotting for detecting protein expression.RESULTS: Homocysteine(0.1-1 mmol/L) increased VSMC proliferation and migration,and the levels of ROS were in a dose-dependent manner.The results of Western blotting showed that homocysteine significantly increased the expression of MCP-1,IL-6 and TNF-?.However,Compared with control group,in GSP(5-20 g/L) group,the increased VSMC proliferation,migration and the production of ROS and the expression of MCP-1,IL-6 and TNF-? mediated by homocysteine were markedly suppressed.EMSA showed that in GSP treatment group,the NF-?B activation was also almost completely inhibited.CONCLUSION: GSP inhibits homocysteine-induced VSMC proliferation,migration and inflammatory response through interfering with ROS dependent on NF-?B signal pathway.
6.Laparoscopic colorectomy for colorectal cancer.
Min TAN ; Baoxian GUO ; Zhimian WU ; Guotai CHEN ; Zhaoxu ZHENG ; Zhenxian ZHAO
Chinese Journal of Surgery 2002;40(10):769-772
OBJECTIVETo evaluate the result of laparoscopic colorectomy in treatment of colorectal cancer.
METHODSLaparoscopic colorectal surgery was performed in 78 patients with colorectal cancer. Operative procedures, complications and postoperative recovery were studied.
RESULTNone of the 78 patients died of laparoscopic colorectal surgery or complications. Eleven patients died from tumor metastasis and 2 from other causes. Twenty-one, 17, 8 patients for 1, 3, 5 years survived respectively. In nine patients who had received operation less than 1 year, no tumor recurrence or metastasis was found except in 1 patient 11 months after operation.
CONCLUSIONLaparoscopic colorectal cancer resection is essential to colectomy for colon and rectum cancer when indicated.
Adult ; Aged ; Aged, 80 and over ; Colectomy ; methods ; Colorectal Neoplasms ; mortality ; pathology ; surgery ; Female ; Humans ; Laparoscopy ; Male ; Middle Aged ; Neoplasm Staging ; Rectum ; surgery
7. Intervention of edaravone against renal injury induced by acute paraquat poisoning in rats
Sheng ZHANG ; Zhaoxu CHEN ; Yingying JIANG ; Qiqi CAI ; Zhihui YANG ; Changrong WANG ; Xiaoyu WU ; Pan YING ; Zhongqiu LU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2017;35(6):408-413
Objective:
To investigate the dynamic change of paraquant-induced kidney injury in rats and the protective effect of edaravone.
Methods:
Eighty SD rats were randomly divided into 4 groups: the normal control group, paraquat poisoning group, edaravone treatment group and edaravone control group. The normal control group of 8 rats were given 1 ml of 0.9% sodium chloride through the abdominal cavity, and the same amount of fluid into the abdominal cavity after 30 minutes. The paraquat poisoning group of 24 rats were given 1 ml of paraquat solution (20 mg/kg) through the abdominal cavity to build poisoning models, and the same amount of 0.9% sodium chloride was injected into the abdominal cavity after 30 minutes. The edaravone treatment group of 24 rats were given edaravone (5 mg/kg) through the abdominal cavity after 30 minutes when the poisoning models were set up. The edaravone control group of 24 rats were given 1 ml of 0.9% sodium chloride through the abdominal cavity, and edaravone (5 mg/kg) was injected into the abdominal cavity after 30 minutes. In addition to the normal control group, the other groups processed 1 times a day to mantain 7 d. On 1, 3, 7, 21 d several rats in each group were excuted and the kidney tissue and serum samples were collected, then each pathological changes of the kidney were observed with light microscopy. Serum creatinine, KIM-1, NGAL were measured by ELISA, the expression of HSP70 protein in kidney were observed with immunohistochemical staining.
Results:
The pathological examination reveald that the damage of kidney tissue in the paraquat group was the most serious on 3 d, and the damage was consistently alleviated in edaravone treatment group at the same time, renal fibrosisn was unseen in each group until 21 d. Compared with normal control group, there was no statistically significant in edaravone control group (
8.A biomechanical comparison of conventional versus an anatomic plate and compression bolts for fixation of intra-articular calcaneal fractures.
Haili WANG ; Zhaoxu YANG ; Zhanpo WU ; Wei CHEN ; Qi ZHANG ; Ming LI ; Zhiyong LI ; Yingze ZHANG
Journal of Huazhong University of Science and Technology (Medical Sciences) 2012;32(4):571-575
The purpose of this study was to compare the biomechanical stability obtained by using our technique featured an anatomical plate and compression bolts versus that of the conventional anatomic plate and cancellous screws in the fixation of intraarticular calcaneal fractures. Eighteen fresh frozen lower limbs of cadavers were used to create a reproductive Sanders type-III calcaneal fracture model by using osteotomy. The calcaneus fractures were randomly selected to be fixed either using our anatomical plate and compression bolts or conventional anatomic plate and cancellous screws. Reduction of fracture was evaluated through X radiographs. Each calcaneus was successively loaded at a frequency of 1 Hz for 1000 cycles through the talus using an increasing axial force 20 N to 200 N and 20 N to 700 N, representing the partial weight bearing and full weight bearing, respectively, and then the specimens were loaded to failure. Data extracted from the mechanical testing machine were recorded and used to test for difference in the results with the Wilcoxon signed rank test. No significant difference was found between our fixation technique and conventional technique in displacement during 20-200 N cyclic loading (P=0.06), while the anatomical plate and compression bolts showed a great lower irreversible deformation during 20-700 N cyclic loading (P=0.008). The load achieved at loss of fixation of the constructs for the two groups had significant difference: anatomic plate and compression bolts at 3839.6±152.4 N and anatomic plate and cancellous screws at 3087.3±58.9 N (P=0.008). There was no significant difference between the ultimate displacements. Our technique featured anatomical plate and compression bolts for calcaneus fracture fixation was demonstrated to provide biomechanical stability as good as or better than the conventional anatomic plate and cancellous screws under the axial loading. The study supports the mechanical viability of using our plate and compression bolts for the fixation of calcaneal fracture.
Biomechanical Phenomena
;
physiology
;
Bone Plates
;
Fracture Fixation
;
methods
;
Fractures, Bone
;
physiopathology
;
surgery
;
Humans
;
Male
;
Middle Aged
9. Compliance rate of screening colonoscopy and its associated factors among high-risk populations of colorectal cancer in urban China
Hongda CHEN ; Ni LI ; Jiansong REN ; Jufang SHI ; Yueming ZHANG ; Shuangmei ZOU ; Zhaoxu ZHENG ; Kai ZHANG ; Min DAI
Chinese Journal of Preventive Medicine 2018;52(3):231-237
Objective:
To evaluate the compliance rate of screening colonoscopy and associated factors in high-risk populations of colorectal cancer (CRC) in urban China.
Methods:
CRC screening data from the Program of Cancer Screening in Urban China conducted in 12 provinces in 2012-2014 was used in the present study. All 97 445 participants were asked to take epidemiological questionnaire survey to evaluate their cancer risk. Participants who were evaluated as "high risk for CRC" were recommended to receive colonoscopy at designated hospitals. Chi-square tests were used to compare the differences of participation rates between groups. Multivariate logistic regression models were applied to explore the potential factors associated withthe compliance rate of screening colonoscopy.
Results:
Overall, 97 445 participants of CRC high-risk were included in this analysis, and 14 949 of them took screening colonoscopy, yielding a participation rate of 15.3%. The participation rate varied greatly across provinces, ranging from 25.2% (2 785/11 071) in Heilongjiang to 9.7% (1 698/17 515) in Liaoning. Moreover, the participation rate in 2013-2014 was significantly higher than that in 2012-2013 (17.1%(9 766/57 280) vs 12.9% (5 183/40 165), χ2=57.67,
10.Long-term oncological and functional outcomes of transanal full-thickness resection after non-curative local resection of early rectal cancer
Fei HUANG ; Zhao LU ; Pu CHENG ; Mingguang ZHANG ; Haipeng CHEN ; Zhaoxu ZHENG
Chinese Journal of General Surgery 2020;35(10):753-756
Objective:To explore the safety of transanal re-excision (TAR) after positive-margin local resection for early rectal cancer.Methods:A retrospective analysis was made data of 44 patients with rectal cancer after local excision from Mar 2006 to Oct 2018 at the Department of Colorectal Surgery, Cancer Hospital of Chinese Academy of Medical Sciences. All patients had positive margin or suspicious tumor remains after local excision, and subsequently salvage TAR surgery was performed after informed consent was given.Results:Forty-four patients after local excision were with pathologically showed residual condition, including 26 cases of positive margin and 18 cases of suspicious tumor remaining. The pathological types were all adenocarcinoma. Forty-one (93%) patients with pT1 and 3 (7%) patients with pT2. The median follow-up time after salvage TAR was 100 (11-164) months. During follow-up, 3 patients (7%) developed mild anal incontinence. One patient (2%) had local recurrence, 3 (7%) patients had distant metastases, and 3 patients (7%) died of non-tumor specific deaths. The overall 5-year survival rate and disease-free survival rate were 98% and 93 %, respectively.Conclusions:Transannal full thickness tumor re-excision is safe and reliable for the salvage treatment after non-complete local resection of early rectal cancer. The long-term follow-up results show that the 5-year survival rate is comparable to that of radical surgical resection, and with a good anal function.