1.Make efforts to improve overall levels of clinical nutriology in China.
Chinese Journal of Gastrointestinal Surgery 2012;15(5):426-428
Clinicians should assume the responsibility of nutritional therapy for satisfactory outcomes. They should master knowledge on nutritional metabolism, and participate in the administration of nutritional support. Clinicians should be acquainted with new concepts and standardized techniques in this field, such as different requirement of energy, understanding of early nutritional support, and optimal regimens of enteral or parenteral nutrition.
China
;
Enteral Nutrition
;
Humans
;
Nutritional Support
;
Parenteral Nutrition
2.Analysis on MRI system eliminable faults in Chinese literature
Xinhuai WU ; Yonghua ZHAO ; Zhouzhu HAN
Chinese Medical Equipment Journal 2003;0(10):-
MRI system,as an imaging diagnosis equipment,plays a very important role in diagnosis and treatment.For the steady avail of MRI system,MRI eliminable faults in CBMDisc(1995~2006) were analyzed.The types and occurrence frequency of MRI eliminable faults were elaborated so as to provide reliable data for reference.
3.Analysis on Chinese literature for MRI major subsystem eliminable faults
Xinhuai WU ; Yonghua ZHAO ; Zhouzhu HAN
Chinese Medical Equipment Journal 1989;0(01):-
MRI system is composed of many independent subsystems, in which RF, Gradient, Coil, MRI magnet subsystem are the most important and complex subsystems. Every subsystem consists of different components. Based on the analysis of MRI eliminable faults in CBMDisc (1995 ~ 2006), the types and occurrence frequency of MRI eliminable faults are expatiated so as to provide reliable data for reference.
4.Application of ARIMA Model to Drug Storeroom in Drug Purchasing Prediction
Jin HAN ; Qingguo ZHAO ; Rongrong WU
China Pharmacy 2007;0(31):-
OBJECTIVE:To explore the new drug purchasing mode using autoregressive integrated moving-average (ARIMA) prediction model for improvement of the working quality and efficiency in hospital drug storeroom.METHODS:Drug consumption data from week 1 to week 47 in 2008 were collected.According to ABC method,category A drugs were defined among which 10 kinds of drugs were sampled randomly.Based on the data of from week 1 to week 44 in 2008,software SPSS13 was applied for the modeling and fitting of ARIMA model.The established model was applied to predict the data of from week 45 to 47,with the predicated data compared with the actual consumption data.RESULTS:The predicted purchasing amount using ARIMA model were consistent with the actual consumption data,with prediction accuracy for quantity at 89.19% and prediction accuracy for whole unit of purchased drugs at 97.56%,respectively.CONCLUSIONS:Good fitting and high short-medium term predication accuracy were obtained in the prediction using ARIMA model,and which could provide scientific support for drug purchasing and help manage the drug stock reasonably without appearance of out of stock or overstock.
5.Analysis on Army Writers of Chinese literature on MRI System Repairing and Maintenance from 1994 to 2007
Xinhuai WU ; Yonghua ZHAO ; Zhouzhu HAN
Chinese Medical Equipment Journal 2004;0(09):-
Based on the analysis on "China biomedical medical literature database"(CBMdisc) in the field of MRI Maintenance composed by army writers from May,1994 to 2007,the following results can be obtained: the total number of writers amounts to 75,106 person-time,27 of them are the first writers,and 11 are main writers;among the total 48 pieces of work,33 pieces are written by more then one writer;the unit with the largest number of published writers is Jinan Military Area Command with Nanjing Military Area Command the second,Lanzhou Military Area Command the third;one main writer has a maximum of 7 pieces.The research makes a close study of the army writers in field of MRI maintenance,indicating the lack of intellectual personnel in the domain of Medicine Engineering in military system.
6.Study and experience from work of computer X-ray photography
Yuefeng HAN ; Xinhuai WU ; Zhouzhu HAN ; Xiangyong GAO ; Yonghua ZHAO
Chinese Medical Equipment Journal 1993;0(06):-
Technology of radiotheraphy has stepped into an era of digital photography and replaced the screen piece combination system.This thesis briefly expounds the advantages and prospect of computer X-ray photography,and discusses its problems and effective solutions in clinical practice.
7.Prognostic value of urine paraquat concentrations combined with poisoning time and creatinine clearance rate ;on prognosis in patients with acute paraquat poisoning
Haitao SHEN ; Na WU ; Jun HAN ; Hang ZHAO ; Xinfei HAN ; Min ZHAO
Chinese Critical Care Medicine 2016;28(10):881-885
Objective To evaluate the prognostic value of urine paraquat (PQ) concentrations combined with poisoning time and creatinine clearance rate (CCr) on prognosis of patients with acute paraquat poisoning (APP). Methods A retrospective case control study was conducted. Clinical data of 96 patients with APP admitted to Department of Emergency of Shengjing Hospital of China Medical University from March 2014 to May 2016 were analyzed. The gender, age, body weight, urine PQ concentrations (determined by semi-quantitative colorimetric method), poisoning time (time from oral poison to urine detection) and CCr of patients were collected, and poisoning index (poisoning index = urine PQ concentrations × poisoning time/CCr) and simplified poisoning index (simplified poisoning index = urine PQ concentrations × poisoning time) were calculated. The patients were divided into death group and survival group according to 2-month outcome after poisoned with clinical data and telephone follow-up. The urine PQ concentrations, poisoning index, and simplified poisoning index between the two groups were compared. Binary classification logistic regression was used to analyze the risk factors affecting prognosis. Receiver-operating characteristic curve (ROC) and diagnostic test were used to analyze the prognostic value of the parameters. Results Compared with survival group, the urine PQ concentrations [mg/L: 30.00 (10.00, 100.00) vs. 10.00 (3.00, 10.00)], poisoning index [mg·h-1·μmol-1: 12.72 (1.86, 33.75) vs. 0.56 (0.18, 1.12)], and simplified poisoning index [mg·h-1·L-1: 600.00 (150.00, 1 000.00) vs. 60.00 (18.00, 120.00)] in death group were significantly increased (all P < 0.01). It was shown by logistic regression analysis that both urine PQ concentrations [odds ratio (OR) = 1.046, 95% confidence interval (95%CI) = 1.006-1.087, P = 0.022] and poisoning index (OR = 1.353, 95%CI = 0.029-1.815, P = 0.031) were independent risk factors affecting the prognosis of patients with APP. It was shown by ROC curve and diagnostic test that the poisoning index had greater area under ROC curve (AUC was 0.902) for evaluating the prognosis of patients with APP. When the best cut-off value was greater than 1.23 mg·h-1·μmol-1, the sensitivity was 90.91%, and the specificity was 73.08%. The AUC of urine PQ concentrations for evaluating the prognosis was 0.759. When the best cut-off value was greater than 20.00 mg/L, the sensitivity was 63.64%, and the specificity was 76.92%. The AUC of simplified poisoning index for evaluating the prognosis was 0.846. When the best cut-off value was greater than 135.00 mg·h-1·L-1, the sensitivity was 81.82%, and the specificity was 76.92%. Conclusion The poisoning index calculated with urine PQ concentrations combined with poisoning time and CCr has prognostic value for prognosis of APP patients, and the prognostic value of poisoning index is greater than that of the urine PQ concentrations alone.
8.Feasibility of Dual Source CT Low Tube Voltage Combined with Iterative Reconstruction in Evaluating Coronary Artery Stents
Jie JIANG ; Xiaojie XIE ; Li WU ; Xunran ZHAO ; Dan HAN
Chinese Journal of Medical Imaging 2015;(4):289-292
Purpose To investigate the second generation dual source CT low tube voltage (100 kV) combined with sonogram-affirmed iterative reconstruction (SAFIRE) in assessing coronary artery stents. Materials and Methods One hundred and fifty-six patients underwent CT coronary angiography after implanted coronary artery stents. Among all the patients, 86 cases were performed with 100 kV combined with SAFIRE, and 70 cases with 120 kV combined with filtered back projection reconstruction (FBP). Mean CT values, image noise, SNR, SAIR, image quality scores, stents detecting and radiation dose of aortic root, inner-stent, and the coronary artery proximal to the stent were compared. Results The mean CT value of aortic root, inner-stent, and the coronary artery proximal to the stent of 100 kV group was higher than that of 120 kV group (t=2.75, 11.77 and 3.19, P<0.05), while image noise and SAIR of 100 kV group were lower than those of 120 kV group (t=-2.53 and -9.51, P<0.05). SNR of aortic root, inner-stent, and the coronary artery proximal to the stent was not statistically different between the two groups (t= -1.34, -0.95 and 1.67, P>0.05). There was no statistic difference of image quality score between the two groups (t= -0.203, P>0.05). Totally there were 243 stents detected, including 67 of right coronary artery, 123 of left anterior descending, 36 of left circumflex, and 17 of other branches. Stent length ranged 3.8 to 98.7 mm and averaged (27.5±16.4) mm. The CTDIvol, DLP and ED of 100 kV group were lower than those of 120 kV group (t= -11.03, -9.41 and -9.41, P<0.05). The effective dosage reduced about 51.5% in 100 kV group when compared with that of 120 kV group. Conclusion The second generation dual source CT low tube voltage (100 kV) combined with SAFIRE in assessing coronary artery stent could meet the diagnostic requirement and reduce the radiation dosage, without increasing image noise and beam hardening artifacts.
9.Effects of high-frequency oscillatory ventilation plus sildenafil in severe persistent pulmonary hypertension of newborns
Yuxiang ZHAO ; Liangrong HAN ; Rong WU ; Donglin JI ; Zhaojun PAN
Chinese Journal of General Practitioners 2013;12(11):918-920
A total of 60 infants with severe persistent pulmonary hypertension (PPHN) at our NICU from January 2006 to December 2012 were divided into research group[(n =32,high-frequency oscillatory ventilation(HFOV) plus sildenafil)]and control group (n =28,HFOV only).Mean pulmonary arterial pulmonary arterial (MPAP),blood gas analysis,oxygenation index (OI),PO2 to fraction of inspired oxygen ratio (PO2/FiO2) before and after treatment were compared between two groups.After 3-day treatment,MPAP (mm Hg)(32 ±6) vs.(43 ±9)mm Hg,PCO2(mm Hg)(36 ±9) vs.(43 ±9),OI(56 ±22) vs.(85 ±21) in research group were significantly lower than those in control group(P < 0.05) ; in comparison with control group,PO2(mm Hg) (89 ±15) vs.(72 ±22),PO2/FiO2(mm Hg) (223 ± 18) vs.(196 ±24) in research group were significantly higher(P < 0.05).The time of ventilation use (d) (5.4 ± 1.3) vs.(6.3 ± 1.6) in research group was shorter than that of control group(P <0.05) while research group showed a higher clinical efficiency rate(%) (81.2 vs.50.0) (P <0.05).A combination of HFOV and sildenafil for severe PPHN can significantly reduce MPAP,shorten the duration of ventilation use and improve cure rate.
10.Observation on efficacy of endoscopic submucosal dissection and endoscopic mucosal resection in the therapy of esophageal mucosal disease
Hongjian JIANG ; Huanqing WU ; Xuejin LI ; Wenliang HAN ; Chunling ZHAO
Chinese Journal of Postgraduates of Medicine 2014;37(7):54-56
Objective To evaluate the outcome and safety of endoscopic submucosal dissection (ESD) versus endoscopic mucosal resection (EMR) in the management of esophageal mucosal lesion.Methods The clinical data of 70 patients with esophageal mucosal lesion were analyzed.Twenty-five patients were treated by ESD (ESD group) and 45 patients were treated by EMR (EMR group).The enbloc resection rate,tissue healing resection rate,operation time,complication and recurrence rate were compared between two groups.Results The enbloc resection rate,tissue healing resection rate in ESD group were significantly higher than those in EMR group [60.0%(15/25) vs.48.9%(22/45),48.0%(12/25) vs.40.0% (18/45)] (P <0.05).The local recurrence rate in ESD group was lower than that in EMR group [4.0% (1/25) vs.20.0% (9/45)] (P < 0.05).The severe complication such as delayed hemorrhage,perforation,stenosis between two groups had no significant difference (P > 0.05).The operation time in ESD group was (64.3 ±27.1) min,and significantly longer than that in EMR group [(27.6 ± 14.1) min] (P <0.05).Conclusions Compare with EMR,ESD has better enbloc resection rate,tissue healing resection rate,and lower recurrence rate.It is more safe and effective in the therapy of esophageal mucosal disease.