1.Minimally invasive posterior reconstructive plating by parallel Kirschner wires for unstable posterior pelvic fractures
Chengming ZHU ; Zhanying SHI ; Juzheng HU ; Renchong WANG ; Jianming HE ; Yongbao QIN
Chinese Journal of Orthopaedic Trauma 2019;21(6):504-510
Objective To explore the clinical efficacy of minimally invasive posterior reconstructive plating by parallel Kirschner wires in the treatment of unstable posterior pelvic fractures.Methods From January 2013 to December 2016,29 patients with unstable posterior pelvic fracture were treated at Trauma Center,Liuzhou Workers' Hospital.They were 22 men and 7 women,aged from 19 to 65 years (mean,44.2 years).By the Tile classification,10 cases were classified as type B and 19 as type C.The delay from injury to surgery ranged from 4 to 14 days (mean,8.7 days).All the patients received minimally invasive posterior fixation with a U-shaped reconstructive plate and parallel Kirschner wires.The length of incision,intraoperative bleeding,operation time,quality of fracture reduction,curative effects and complications at the last follow-up were recorded.Results The length of intraoperative unilateral incision ranged from 2.3 to 3.4 cm (average,2.99 cm);the volume of intraoperative bleeding ranged from 47 to 88 mL (average,69.9 mL);the average operation time ranged from 17 to 34 min (average,25.2 min).One patient was lost to the follow-up.The other 28 patients were followed up for 14 to 26 months (average,18.3 months).The fracture healing time ranged from 8 to 15 months (average,10.1 months).According to the Matta criteria for fracture reduction,17 cases were rated as excellent at the last follow-up,9 as good,one as fair and one as poor,giving an excellent to good rate of 92.9%.According to the Pohlemann functional scoring,14 cases were rated as excellent,11 as good,2 as fair and one as poor,giving an excellent to good rate of 89.3%.Conclusion In the treatment of unstable posterior pelvic fractures,minimally invasive posterior reconstructive plating by parallel Kirschner wires presents advantages of high security,limited surgical trauma,good curative effects and limited postoperative complications.
2.Report quality assessment and study characteristic analysis of randomized controlled trials published in Chinese Journal of Health Management
Yanli NIE ; Jie YANG ; Zhanying SHI ; Lin ZENG
Chinese Journal of Health Management 2020;14(4):339-344
Objective:To evaluate the report quality and study characteristics of randomized controlled trials (RCT) published in the Chinese Journal of Health Management.Methods:All studies published in the Chinese Journal of Health Management from January 2007 to July 2019 were retrieved via Wanfang data. Two researchers screened the articles strictly according to the inclusion and exclusion criteria independently. Based on the Consolidated Standards of Reporting Trials (CONSORT) statement 2010, the report quality and characteristics of the articles (including the type of participants, recruiting site, interventions, outcome measure, etc.) were extracted and summarized. Then the report quality, study characteristics were analysed among three periods based on the publishing date (2008—2011 , 2012—2015 , 2016—2019). Results:Titles, abstracts, and full text manuscripts were screened against inclusion criteria by two independent reviewers and 57 studies were included. There were 13/25 items of the CONSORT statement were fulfilled completely, the other 8/25 items were partly fulfilled, and the else 4/25 items were not met the standards in these studies. There was statistically significant difference in the description ratio of ‘randomization sequence generation’ (16.7% vs. 47.6% vs. 66.7%), foundation (25.0% vs. 33.3% vs. 75.0%) and informed consent (50.0% vs. 76.2% vs. 100.0%) during the three periods (all P<0.05). There was no statistically significant difference in the proportion of chronic diseases (58.3% vs. 85.7% vs. 66.7%), the description ratio of participant flow (41.7% vs. 33.3% vs. 75.0%) and baseline data (83.3% vs. 95.2% vs. 100.0%) in the studies from different periods, however, the description situation of participant flow and baseline data has been improved along the time. Conclusion:According to the CONSORT statement, it is found that the quality of research in health management still needs to be improved, especially in the concealment of randomization and trial registration.
3.A comparative study of orthopaedic robot and O-arm navigation to pelvic fractures
Chengzhi YANG ; Zhanzhu HUANG ; Jingli TANG ; Dan ZHOU ; Jianming HE ; Juzheng HU ; Zhanying SHI
Chinese Journal of Orthopaedics 2021;41(19):1387-1395
Objective:By comparing the clinical effect of minimally invasive hollow screw internal fixation Assisted by orthopedic robot (TiRobot) and O-arm navigation in the treatment of pelvic fractures, and practicability and security of both treatments were evaluated.Methods:Retrospective analysis of data of 42 cases of Tile C type pelvic fractures was employed during June 2017 to June 2020. Among them, 32 cases, twenty-four men, eight women, aged 34±6.2 years (range 24-68 years), were treated with percutaneous screw fixation guided by O-arm X wire instrument. According to Tile classification, there were 3 cases of C1.1 type, 8 cases of C1.2 type and 21case of C1.3 type. According to the Denis classification of sacral fractures, 17 cases were in zone I, and 8 cases in zone II. Ten patients, eight males and two females, aged 36±5.2 years (range 19-62 years) were treated by percutaneous screw fixation assisted by orthopedic robot. According to Tile classification, there were 1 case of C1.1 type, 2 cases of C1.2 type and 7 cases of C1.3 type. According to the Denis classification of sacral fractures, there were 5cases in zone I, 2 cases in zone II. For those who got obviously displaced pelvic fractures, Starr frames were used and then internal fixation was used to fix pelvic anterior ring and posterior ring injury respectively. Based on the times of needle adjustments, intraoperative fluoroscopy time, good screw position and incidence of complications two groups were statistically analysed. Matta score was employed to evaluate the quality of fracture reduction, while the Majeed score was employed to evaluate the clinical efficacy. Through the two groups of cases guide needle adjustment times, intraoperative fluoroscopy time, screw position excellent and good rate and the incidence of complications, which were statistically analyzed.Results:All screw positions were confirmed by CT scan after operation. The average time required for each screw placement of the O-arm group was 7.36±2.63 s, of the robot group was 6.80±3.20 s, so difference was not statistically significant ( P<0.05). An average of screw adjustments per one screw was 1.56±0.02 times by O-arm, and by the robot group was 0.34±0.06 times, so differences between the two groups were statistically significant ( P>0.05). The average operating time of O-arm group was 53.86±15.06 min, while the robot group was 52.52±15.14 min, so differences between the two groups were not statistically significant ( P>0.05). Position distribution of screw placement in two groups, all screws in O-arm group of position evaluations were excellent, excellent rate was 100%, all screw position evaluations by robot were excellent, excellent rate was 100%, so difference in screw distribution between the two groups was not statistically significant ( P>0.05). All cases were followed up for 6-12 months. Fracture healing time: 34.6±8.6 weeks for O-arm group, 33.4±9.4 weeks for robot group. Comparison between the two groups was not statistically significant ( P>0.05). Majeed score of O-arm group was 55-87, including Excellence of 17 cases, goodness of 9, fairness of 6. The rate of excellence and goodness was 81.2%, while robot group was 76-95, and that were excellent 7 cases,1 good, and the excellent and good rate was 80%, there was no significant difference between Matta and Majeed score between the two groups ( P>0.05). The incidence of complications between the two groups were no statistically significant ( P>0.05). Conclusion:Orthopedic robot system and O-arm navigation system assisted by percutaneous hollow screw fixation treatment of pelvic anterior and posterior ring injury, which are accurate, safe, minimally invasive, can reduce radiation damage to patients and surgeons. The efficacy were satisfactory. Both treatments are ideal for minimally invasive treatment of pelvic fractures, and the orthopedic robot have advantages of being programmed, standardized, stable and it’s learning curve is shorter.
4. Preliminary application of Starr reduction framecombined with O-arm navigation systemin the treatment ofcomplex pelvic fractures
Juzheng HU ; Zhanying SHI ; Renchong WANG ; Hao WU ; Haiwei YAN ; Zhanzhu HUANG ; Chunhua MAO ; Dan ZHOU ; You XIE
Chinese Journal of Orthopaedics 2019;39(13):817-825
Objective:
To investigate the feasibility and short term clinical efficacy of early minimally invasive treatment of complex pelvic trauma with Starr reduction frame combined with O-arm navigation system.
Methods:
From June 2017 to December 2018, thirty two patients with Tile C complex pelvic fractures were prospectively divided into two groups according to the random number table. The open treatment group included 17 cases (open reduction and internal fixation group; 10 males and 7 females, age 24-60 years, average 37±6.5 years; according to Tile classification, 8 cases of C1 type, 8 cases of C2 type and 1 case of C3 type; according to the Denis classification of sacral fractures, 9 cases in zone I, 6 cases in zone II and 2 cases in zone III). The combined treatment group included 15 cases (Starr reduction frame group combined with O-arm navigation system, 8 males and 7 females, age 32-57 years, average 40±5.2 years; according to Tile classification, 8 cases of C1 type, 6 cases of C2 type and 1 case of C3 type; according to the Denis classification of sacral fractures, 8 cases in zone I, 5 cases in zone II and 2 cases in zone III). The ilioinguinal and Stoppa approaches were used in the open treatment group, and the anterior and posterior ring injuries were fixed with reconstruction plate screws and hollow screws, respectively. In the combined treatment group, starr frame was used to assist reduction, combined with "O" arm navigation technique, infix internal fixation frame, superior pubic branch screw, sacroilium screw were used to fix the anterior and posterior ring injury. The quality of pelvic fracture reduction was evaluated by the Matta scoring system, and the Majeed score was used to evaluate the clinical efficacy.
Results:
All patients were followed up for 6 to 12 months. The hospitalization time (45±11 d), operation time (220.0±49.4 min) and fracture healing time (24.0±5.6 weeks) in the open treatment group were longer than those in the combined treatment group (21±9 d, 180.0±24.2 min, 16.1±3.8 weeks), and the intraoperative blood loss (820.0±140.4 ml) was significantly higher than that in the combined treatment group (24.0±10.4 ml)(
5.Design and finite element analysis of a new type of plate for hyperextension varus tibial plateau fractures
Zhongshuai LIANG ; Renchong WANG ; Lu ZHANG ; Juzheng HU ; Zhanying SHI ; You XIE ; Chunhua MAO
Chinese Journal of Tissue Engineering Research 2024;33(33):5283-5288
BACKGROUND:There is currently no anatomic locking plate suitable for the anteromedial platform,so the medial locking plate of the tibial plateau is usually placed forward to fix anteromedial compression fractures caused by hyperextension varus injury.Due to the inability of the locking screw to achieve vertical fixation of the fracture line,coupled with the influence of the patellar ligament,the clinical results are still unsatisfactory. OBJECTIVE:To compare the biomechanical performance of a new type of plate with traditional internal fixation methods in treating hyperextension varus tibial plateau fractures through finite element analysis. METHODS:CT data of 20 cases of hyperextension varus tibial plateau fractures were collected,and their morphological characteristics,such as medial posterior tibial slope,the medial articular fracture angle,surface area,and anterior cortical height were measured.A 24-year-old male volunteer with a height of 175 cm and a weight of 65 kg was selected,and his tibial CT data were imported into Mimics 21.0 software to generate a 3D model.Then,internal fixation models were imported into SolidWorks 2017 software.New type of plate,medial locking plate,posterior medial locking plate,and 6.5 mm hollow screws fixed data models were established based on the measured morphological data.Ansys 17.0 software was used to load stress on the four fixation models and compare their biomechanical performance. RESULTS AND CONCLUSION:(1)With the increase of axial load,the peak stresses of different internal fixation models approximately increased proportionally.At 500 N,the peak stress values were as follows:screw group(6.973 7 MPa)
6.3D navigation-assisted percutaneous sacroiliac screw fixation for Tile C1 pelvic fractures
Zhijie XI ; Wen SHU ; Jie LI ; Shuzhong HUANG ; Zhanying SHI
Chinese Journal of Orthopaedics 2023;43(19):1316-1323
Objective:To analyze the clinical efficacy of three-dimensional (3D) navigation-assisted percutaneous sacroiliac screw fixation in the treatment of Tile C1 pelvic fractures.Methods:A total of 12 patients with Tile C1 pelvic fractures who underwent percutaneous sacroiliac screw fixation assisted by 3D navigation in Liuzhou People's Hospital Affiliated to Guangxi Medical University from September 2019 to March 2022 were retrospectively analyzed. There were 8 males and 4 females, aged 43.08±16.93 years (range, 21-72 years). 24 patients with Tile C1 pelvic fractures who underwent fluoroscopy-assisted percutaneous sacroiliac screw internal fixation during the same period were selected as controls by pairing them according to age and sex in a ratio of 1:2. There were 15 males and 9 females, aged 45.75±11.69 years (range, 32-75 years). The operation time, intraoperative blood loss, number of screws, intraoperative fluoroscopy times, guide pin drilling times and pelvic function scores were compared between the two groups. The quality of pelvic fracture reduction was evaluated based on the Matta scoring criteria, the screw cut-out rate was calculated according to the Lonstein evaluation criteria, and the degree of postoperative heterotopic ossification was evaluated according to the Brooker grading system.Results:All patients were followed up for 18.1±4.7 months (range, 12-30 months). In the 3D navigation group, the operation time was 110.67±44.85 min, the number of intraoperative fluoroscopies was 24.42±9.94, and the number of guided needle drilling was 7.33±4.70, which was lower than 145.00±48.51 min, 75.75±29.47, and 13.92±5.78 in the fluoroscopically-assisted group, and the differences were statistically significant ( P<0.05). At the last follow-up, the Majeed pelvic function score of 3D navigation group was 89.08±3.89, and the excellent and good rate was 100% (12/12). The score of fluoroscopy-assisted group was 74.00±10.71, and the excellent and good rate was 79% (19/24). The difference was statistically significant ( χ2=10.23, P<0.001). The excellent and good rate of Matta grading was 92% (11/12) in the 3D navigation group and 79% (19/24) in the fluoroscopic assisted group, showing no significant difference between the two groups ( χ2=2.93, P=0.403). The screw cut-out rate and heterotopic ossification rate in the 3D navigation group were 17% (2/12) and 8% (1/12), which were lower than 71% (17/24) and 13% (3/24) in the fluoroscopy-assisted group, and the differences were statistically significant ( χ2=9.76, P=0.021; χ2=31.71, P<0.001). Conclusion:3D navigation-assisted percutaneous sacroiliac screw fixation for Tile C1 pelvic fractures can reduce the operation time and radiation exposure, improve the postoperative pelvic function, and reduce the incidence of screw cut-out and heterotopic ossification.
7.Clinical study of bone transport combined with bone graft and internal fixation at the docking site in the treatment of large segmental bone defect in lower limb
Juzheng HU ; Zhanying SHI ; Chengzhi YANG ; Renchong WANG ; Hao WU ; Chengming ZHU ; You XIE ; Chunhua MAO
Chinese Journal of Orthopaedics 2018;38(5):280-287
Objective To explore the feasibility and clinical value of Ilizarov bone transport technique combined with bone graft and internal fixation at the docking site in the treatment of large segmental bone defect of the lower limbs.Methods Thirty patients with large lower limbs bone defects were prospectively divided into two groups according to the random number table:pure bone transport group (Ilizarov bone transport technique alone,n=lS,10 males and 5 females,average age 34.4±4.6 years old,2 cases bone defect of femur,13 cases tibia,and the length of bone defect 6.2±2.4 cm),and combined bone transport group (Ilizarov bone transport technique with bone graft and internal fixation at the docking site,n=lS,12 males and 3 females with the average age of 33.8±5.2 years,1 case of bone defect and 14 tibia,and the length of bone defect 6.5±2.2 cm).The preoperative hospital for special surgery (HSS) knee functional scores,Baird-Jackson ankle function scores,external fixation time,external fixation index,bone union time,bone union index,postoperative ASAMI scores and incidence of complications were compared between the two groups.Results All patients were followed up for 9 to 24 months (mean 16.2 months).Pure bone transport group was followed up for 9 to 24 months (mean 16.2 months),and combined bone transport group was 10 to 24 months (mean 16.4 months).In pure bone transport group,the external fixation time was 17.6±5.4 months,and the bone union time was 11.2±3.1 months with the average bone union index 42.4±4.6 d/cm.While in combined bone transport group,the external fixation time of group B was 8.4± 2.1 months,and the bone union time was 7.2±2.1 months with the average bone union index 21.1±2.7 d/cm.The external fixation index of pure bone transport group was 32.4±2.1 d/cm,while in combined bone transport group it was 32.1±2.5 d/cm,and there was no significant difference between these two groups (t=0.812,P=0.884).According to the bone and function score of the ASAMI,in pure bone transport group,bone healing:excellent 6 cases,good 6 cases,fair 2 cases,poor 1 case,excellent rate was 80%.While in combined bone transport group:excellent in 8 cases,good 6 cases,fair 1 case,excellent rate was 93.3%.The difference between the two groups was statistically significant (X2=10.6,P=0.032).The lower limb function in pure bone transport group:excellent in 5 cases,good in 5,fair in 4,poor in 1,excellent rate was 66.7%;while in combined bone transport group:excellent in 6 cases,good in 7,fair in 2,excellent rate was 86.7%.There was also a significant difference in the incidence of complications between the two groups.Conclusion Both the pure Ilizarov bone transport technique and the Ilizarov technique with bone graft and internal fixation at the docking site could satisfactorily treat the large bone defect and shortening of the lower limb.But the latter technique had shorter healing time,higher healing rates,better limb function and fewer complications.
8.Treatment of acetabular anterior column fracture with percutaneous screw fixation with laser-assisted axial fluoroscopy
Juzheng HU ; Zhanying SHI ; Renchong WANG ; Hao WU ; You XIE ; Chunhua MAO ; Boyu LIU ; Jingli TANG ; Chengming ZHU ; Dan ZHOU ; Bing LI
Chinese Journal of Orthopaedics 2020;40(5):302-309
Objective:To investigate the feasibility and clinical efficacy of percutaneous screw fixation for acetabular anterior column fracture with laser-assisted axial fluoroscopy.Methods:Data of 20 patients (22 sided) with acetabular anterior column fracture treated by percutaneous screw fixation with laser-assisted axial fluoroscopy from January 2017 to December 2018 were retrospectively analyzed. There were 11 males and 9 females with an average of 42.1±3.2 years (range, 24-68 years). There were 7 cases of unilateral acetabular anterior column fracture, 2 cases of bilateral acetabular anterior column fracture (4 sides), 7 cases of anterior column with ipsilateral sacral fracture, and 4 cases of anterior column with sacroiliac joint injury. There were 3 hips of Area I, 6 Area II, 13 Area III of acetabular anterior column fractures according to Nakatani partition. The time from injury to surgery was 5 days (range, 3-11 days). All patients with acetabular anterior column fractures were fixed by percutaneous screw fixation with laser-assisted axial fluoroscopy, and patients with sacral fracture or sacroiliac joint injury were fixed by percutaneous sacroiliac screws with Starr frame-assisted reduction. The time of operation, the number of intraoperative fluoroscopy and the amount of intraoperative bleeding were recorded. Matta scoring criteria were used to assess fracture reduction quality, and hip function was assessed at the last follow-up according to the modified Merle D' Aubigné and Postel scoring system.Results:The average operative time was 22±10 min (range, 20-40 min) with an average times of intraoperative fluoroscopy of 30±8 times (range, 21-45 times), and the amount of intraoperative blood loss was 20±5 ml (range, 10-40 ml). 20 patients were followed up after operation for a period of 14±3.1 months (range, 12-18 months). The quality of postoperative fracture reduction was assessed according to the Matta acetabular fracture reduction criteria: anatomical reduction in 18 hips, satisfactory reduction in 2 hips, unsatisfactory reduction in 2 hips, with an excellent and good rate of 91% (20/22). The fracture healing time was 13±2.2 weeks (range, 11-16 weeks). At the lastest follow-up, hip function was assessed according to the modified Merle D' Aubigné and Postel scoring system: excellent 18, good 3, fair 1, and the satisfactory rate was 95%(21/22). No major neurological, vascular injury, wound infection and ectopic ossification were found during follow-up.Conclusion:Using laser-assisted axial fluoroscopy percutaneous screw to treat acetabular anterior column fracture, the operation is simple. And there is low risk to damage important blood vessels and nerves. This method can shorten the operation time of acetabular anterior column fracture, reduce the amount of blood loss during the operation, and the outcome is satisfactory.
9.Application of cellular metabolomics in central nervous system diseases
Xiaoli HE ; Yiwei SHI ; Hui WANG ; Jianying DAI ; Zhanying HONG
Journal of Pharmaceutical Practice 2023;41(2):63-69
Cell metabolomics is an important branch of metabolomics, which could dynamically monitor cell response and metabolic changes after drugs acting on cells, and look for potential biomarkers. Cell metabolomics has been widely used in illustration of disease mechanism, evaluation of drug efficacy and development of new drug through elucidating the pathophysiological mechanism of the disease and the effect of drug treatment intervention. The researches process of cellular metabolomics and its application in central nervous system diseases were reviewed in order to provide theoretical basis for in-depth study of the pathogenesis and prevention and treatment of central nervous system diseases.
10.Evaluation of toxin-induced injury and protective effect of triptolide based on a cardiovascular chip model
Xiaoli HE ; Yiwei SHI ; Lan CHEN ; Yue LIU ; Zhanying HONG
Journal of Pharmaceutical Practice 2023;41(3):149-154
Objective To construct a cardiovascular chip model for evaluating the damage of vascular glycocalyx induced by four marine toxins: okadaic acid (OA), conotoxin (CTX), tetrodotoxin (TTX) and gymnodimine (GYM), and explore the protective effect of triptolide on toxin-induced injury. Methods Human umbilical vein endothelial cells(HUVEC) were inoculated into a three-channel microfluidic chip. CCK-8 method and immunofluorescence staining were used to analyze the damage of cell viability and glycocalyx tissue induced by low, middle and high concentrations of marine toxin, as well as the protective effect of triptolide on toxin-induced injury. Results The cells in the cardiovascular chip grew well and had structurally intact glycocalyx. Compared with the control group, the activity of HUVEC cells were inhibited in group of the medium and high concentration of OA and high concentration of GYM (P<0.05). The activity of cells had not been inhibited by CTX and TTX significantly , but all the four toxins caused serious damage to the glycocalyx tissue (P<0.01). After pre-protection with triptolide, the toxicity of the four toxins to HUVEC cells and the damage rate of glycocalyx decreased significantly. Conclusion The four marine biotoxins could damage the activity and glycocalyx of HUVEC cells in a dose-dependent manner, while triptolide has a protective effect on HUVEC cells injured by toxin.