1.A modified surgical technique of robot-assisted inferior vena cava thrombectomy for patients with left renal cell carcinoma and tumor emboli: a report of 7 cases eliminating preoperative interventional embolization
Shengzheng WANG ; Jinshan CUI ; Zhenhao LI ; Yunlong LIU ; Shuanbao YU ; Yafeng FAN ; Zhaowei ZHU ; Jin TAO ; Xuepei ZHANG
Journal of Modern Urology 2025;30(2):128-132
Objective: To explore the safety and feasibility of the disconnection of the left renal artery preferentially during robot-assisted inferior vena cava (IVC) thrombectomy for patients with left renal cell carcinoma and tumor emboli. Methods: Clinical data of 7 patients who underwent robot-assisted IVC thrombectomy and radical nephrectomy in the First Affiliated Hospital of Zhengzhou University during Dec.2021 and Oct.2024 were retrospectively analyzed.Thrombectomy was performed first,followed by nephrectomy. The “IVC-first, kidney-last”robotic technique was developed to minimize chances of IVC thrombus. When patients in left lateral decubitus position, the left renal artery was severed from the right side through the inferior vena cava and abdominal aorta. After removal of thrombus from IVC was completed, patients changed to the right lateral position to complete radical left nephrectomy. Results: Imaging examinations revealed that the median diameter of the renal cell carcinomas was 83(46-99) mm; the median length of the inferior vena cava cancerous emboli was 49(2-91) mm.According to the Mayo classification,the cancerous emboli were gradeⅠ in 2 cases,gradeⅡ in 4 cases,and grade Ⅲ in 1 case.All surgeries were successful.The median operation time was 248(201-331) minutes,blood loss 500(200-1000) mL,and 6 cases required intraoperative blood transfusion.The median time for transition into the intensive care unit was 1(1-4) days,and drainage tube removal 6(5-12) days.Serum creatinine increased significantly in 5 cases,4 of which returned to normal after 1 week,but 1 had renal insufficiency (creatinine 166 μmol/L).Chylous fistula occurred in 1 patient,and lower extremity venous thrombosis developed in 3 patients.Pathological examinations indicated 6 cases of renal cell carcinoma and 1 case of MiT family translocation renal cell carcinoma.During the median follow-up of 17(1-35) months,5 cases were tumor-free,while 2 had lung and retroperitoneal metastases.They received targeted therapy of axitinib combined immunotheraphy and lived with tumors. Conclusion: In the left lateral position for left renal cell carcinoma with cancerous emboli,robot-assisted laparoscopic thrombectomy by crossing the inferior vena cava and abdominal aorta and disconnecting the left renal artery first is safe and feasible.
2.Practice pathway and effectiveness evaluation of GCP resident pharmacists in the management of dermatolo-gical drug clinical trials
Yunlong WANG ; Limin ZHOU ; Hua ZHANG ; Quanchao LI
China Pharmacy 2025;36(20):2507-2511
OBJECTIVE To explore the practice pathway and evaluate the effectiveness of the resident pharmacists stationed in the Drug Clinical Trial Institution Office (hereinafter referred to as the “GCP resident pharmacist”) in the management of dermatological drug clinical trials. METHODS The practical approach of GCP resident pharmacists participating in dermatological drug clinical trials at our hospital was introduced. A retrospective analysis was conducted on the data of dermatological drug clinical trials from 2021 to 2024, comparing efficiency and quality indicators between dermatological clinical trials and those of other specialties. RESULTS With the involvement of our hospital’s GCP resident pharmacists throughout, the process for dermatology drug clinical trials was constructed and optimized, a dedicated quality control system was established, and the acceleration strategy for subject enrollment was optimized. The number of dermatological drug clinical trials at our hospital showed a compound annual growth rate of 69.56% from 2021 to 2023. In terms of efficiency indicators, the approval waiting time for dermatological drug clinical trials was (12.31±4.99) days, which was significantly shorter than that of other specialties ([ 19.68±6.09) days, P<0.05]. Regarding quality indicators, the enrollment rate for dermatological drug clinical trials was 75.71%(50.00%,114.48%), which was significantly higher than that of other specialties [51.00%(25.00%,174.17%), P<0.05]. The numbers of first quality control issues ([ 8.31±3.25)items vs.( 11.68±4.49)items] and protocol deviations [5.5(2.0,11.0)times vs. 11.0(5.5,17.5)times] were significantly lower than those of other specialties (P<0.05). CONCLUSIONS GCP resident pharmacists significantly enhance the overall efficiency of dermatological drug clinical trials, playing a crucial role in ensuring the reliability and authenticity of drug clinical trials, as well as safeguarding the rights and safety of trial subjects.
3.Treating secondary organizing pneumonia after infection based on Sanjiao membranous tube theory
Yanni LI ; Xiaomei ZHANG ; Tianshu YANG ; Yunlong SUN ; Mengqian LI ; Yuxin LAI ; Liangduo JIANG
Journal of Beijing University of Traditional Chinese Medicine 2025;48(6):746-750
Secondary organizing pneumonia after infection is a pathological condition characterized by connective tissue filling and obstructing the alveoli and bronchioles, in which following an infection in the lung, the inflammatory response is not controlled in a timely and effective manner. The pathogenesis and treatment of this condition can be interpreted through the Sanjiao membranous tube theory and the concept of stagnation within the pulmonary micro-membrane. Sanjiao is conceptualized as a four-way membranous tube that internally connects with the zangfu organs and externally with the skin and muscles, enabling the circulation of energy and fluids throughout the body. It also maintains communication with the zangfu micro-membranes. Within the lungs, the pulmonary micro-membrane is distributed and connected to the upper jiao membranous tube, facilitating the movement of qi and fluids and supporting nutrient distribution. External pathogens may invade the Sanjiao membranous system through the external membranous tube, travel internally along this system, and transform into latent pathogens that settle within the pulmonary micro-membrane. These latent pathogens can subsequently transform into heat or dampness, leading to the depletion of lung qi and impairing the lung′s ability to regulate and transport body fluids. Consequently, fluids may seep into the pulmonary micro-membrane, where they are transformed into dampness, turbidity, and phlegm. The accumulation of damp-turbidity and phlegm obstructs the flow of qi and blood, resulting in blood stasis in the pulmonary collaterals. This stagnation occurring within both the pulmonary micro-membrane and its associated collaterals underlies the development of secondary organizing pneumonia after infection. In severe cases, this condition may progress to pulmonary interstitial fibrosis. The therapeutic approach emphasizes expelling latent pathogens, regulating and dredging the pulmonary micro-membrane, tonifying the healthy qi, and supporting health. Regulating and dredging the pulmonary micro-membrane is a crucial step, with a focus on promoting the flow of lung qi, resolving dampness and phlegm, and activating blood circulation to remove stasis.
4.Perifornical UCN3 Neurons Regulate Overeating-Induced Weight Gain.
Shanshan LU ; Xinran ZHANG ; Wanqi CHEN ; Baofang ZHANG ; Haiyang JING ; Yunlong XU ; Fengling LI ; Chenyu JIANG ; Gaowei CHEN ; Xiaofei DENG ; Yingjie ZHU
Neuroscience Bulletin 2025;41(6):1103-1108
5.Preparation of monoclonal antibodies with high specificity for glycated hemoglobin and establishment of a rapid detection method.
Chaofan YIN ; Yingfu ZHANG ; Kebei WANG ; Jichuang WANG ; Yongwei LI ; Xiaojun WANG ; Xudong WANG ; Panpan SHI ; Yunlong WANG
Chinese Journal of Biotechnology 2025;41(8):3165-3177
Hemoglobin A1c (HbA1c) has a unique structure that makes monoclonal antibody (mAb) preparation challenging. This study aims to develop a method for preparing HbA1c mAbs and establish a fluorescent immunochromatographic assay (FICA) for rapid detection of HbA1c. Three glycosylated peptides were synthesized and used to prepare complete antigens, which were identified by dot enzyme-linked immunosorbent assay (Dot-ELISA) and ultraviolet absorption spectroscopy. The complete antigens and natural HbA1c were used for cross-immunization of mice, and the optimal complete antigen was selected. The mouse with the highest serum titer was chosen for mAb preparation. The purity and specificity of the mAbs were verified, and a FICA method was developed. The optimal complete antigen, with a titer of 1:512 000, was successfully prepared and selected. Fusion with splenocytes resulted in four specific HbA1c antibodies (purity > 90%). The best antibody exhibited a binding constant (Ka) of 1.67×1010 L/mol with the antigen. Based on this antibody, a FICA method was successfully established, capable of producing results within 15 min. The method demonstrated a good linear range (3%-13% HbA1c, y=0.071 3x+0.005 6, R2=0.993 7), recovery rates of 98%-102%, precision < 10.00%, and no nonspecific reactions. Clinical testing of 210 samples showed positive agreement of 96.36%, negative agreement of 97.00%, and overall agreement of 96.68%. The receiver operating characteristic (ROC) curve analysis yielded an area under curve (AUC) of 0.980 9 [95% confidence interval (CI): 0.961 0-1.000 0], with high consistency verified in multicenter studies. We successfully developed a key technique for preparing HbA1c monoclonal antibodies and established a FICA method for rapid detection of HbA1c. It will provide an efficient and convenient detection method for the early diagnosis and long-term management of diabetes and its complications.
Antibodies, Monoclonal/biosynthesis*
;
Animals
;
Mice
;
Glycated Hemoglobin/immunology*
;
Mice, Inbred BALB C
;
Humans
;
Antibody Specificity
;
Chromatography, Affinity/methods*
;
Enzyme-Linked Immunosorbent Assay/methods*
;
Female
6.Research progress on the intervention of traditional Chinese medicine in renal interstitial fibrosis based on PI3K/Akt signaling pathway
Xue LI ; Yunlong ZHANG ; Ziyi SONG ; Zhujiang ZHANG ; Chao YANG ; Tianjiao REN ; Linzhen JIA
China Pharmacy 2024;35(14):1795-1800
Renal interstitial fibrosis(RIF) is the main pathological manifestation of chronic kidney disease. Due to the complexity of the mechanism, there is no specific treatment for RIF in clinical practice. The abnormal activation of the phosphatidylinositol 3-kinase (PI3K)/protein kinase B(Akt) signaling pathway and the activation of downstream target genes are key drivers of RIF induction and progression. Traditional Chinese medicine has the characteristics of precise efficacy and minimal toxic side effects, and the occurrence and development of RIF can be regulated by multiple targets and mutual coordination. This review focuses on the PI3K/Akt signaling pathway and summarizes the potential targets and regulatory mechanisms of traditional Chinese medicine in the treatment of RIF. It is found that various effective ingredients (such as sinomenine, mangiferin, coumarin derivates from Hydrangea paniculata, etc.) and formulas (such as Fushengong decoction, Qi-Bang-Yi-Shen formula, etc.) of traditional Chinese medicine can inhibit fibroblast proliferation, improve inflammation and oxidative stress, maintain mitochondrial stability, and slow down ferroptosis through this pathway, thereby delaying the occurrence and progression of RIF.
7.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
8.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
9.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.


Result Analysis
Print
Save
E-mail