1.Additive Manufacturing and Its Medical Applications.
Zewen SONG ; Guohui WANG ; Qin GAO ; Shaihong ZHU
Journal of Biomedical Engineering 2015;32(2):485-488
Additive manufacturing (AM) is a collection of technologies based on the layer-by-layer manufacturing. Characterized by its direct manufacturing and rapidity, it has been regarded by the Economist Journal as one of the key techniques which will trigger the third industry reformation. The present article, beginning with a brief introduction of the history of AM and the process of its major technologies, focuses on the advantages and disadvantages and medical applications of the technique.
Medicine
;
Printing, Three-Dimensional
2.Dual stent placements for occlusion/stenosis of subclavian artery associated with stenosis of adjacent vertebral artery initial site
Wei MU ; Yue LIU ; Jingxian ZHANG ; Jin SHEN ; Feng GAO ; Zewen SU ; Xiaojun LIU ; Haiyan WANG
Journal of Interventional Radiology 2015;(10):865-868
Objective To evaluate the efficacy of dual stent placements for the treatment of occlusion/stenosis of subclavian artery associated with stenosis of adjacent vertebral artery initial site. Methods The clinical data of 9 patients with occlusion/stenosis of subclavian artery associated with stenosis of adjacent vertebral artery initial site were retrospectively analyzed. Stent implantations in the affected subclavian artery and vertebral artery were separately performed; the patients were followed up for 3-12 months after the treatment. The therapeutic efficacy was evaluated with the clinical symptoms and Doppler ultrasonic examination. Results Successful implantation of two stents was accomplished in all 9 patients, with the technical success rate of 100%. After the treatment, the blood flow in both the subclavian and vertebral arteries was unobstructed. Following-up examination showed that the subjective symptoms were obviously improved in all 9 patients, and no serious procedure-related complications occurred. Doppler ultrasound examination showed that no in-stent restenosis or stent displacement was observed. Conclusion For the treatment of occlusion/stenosis of subclavian artery associated with stenosis of adjacent vertebral artery initial site, dual stent placement technique is a safe and feasible means with satisfactory effect in improving vertebro-basilar arterial insufficiency.
3.Effect of the size,number or location of fibroids on therapeutic efficacy of uterine artery embolization
Wei MU ; Shuangyong CHANG ; Yu'e LIU ; Jingxian ZHANG ; Jin SHEN ; Feng GAO ; Zewen SU ;
Chinese Journal of Primary Medicine and Pharmacy 2015;(13):1927-1929,1930
Objective To evaluate whether the size,number or location of fibroids affect therapeutic efficacy of uterine artery embolization (UAE).Methods 84 patients with symptomatic uterine fibroids who had received uterine fibroid embolization with the use of polyvinyl alcohol(PVA)or gelfoam sponge particles(GSP).According to the lesion's size,number or location,all patients were divided into different groups and following -up as outpatients. Patient's symptomatic improvement and imaging following -up was assessed after UAE.Results A technically suc-cessful embolization was done in all patients.Postoperative 12 -month following -up was performed in 77 cases.No major life -threatening complications were found and the clinical symptoms were improved after UAE.In the different groups,the uterine size and the leiomyoma size after UAE were markedly decreased(t =5.842,P <0.05).Further comparison showed that the mean reduction in fibroids volume after UAE was not significant between the two groups, so was the mean reduction in uterine volume.Solitary leiomyoma group showed no significant difference in volume reduction rate of fibroids and uterine after UAE as compared with multiple leiomyoma group.Changes were not signifi-cantly in Submucosal uterine fibroids,Subserosal uterine fibroids,Intramural uterine fibroids.Conclusion UAE is an effective treatment for uterine fibroids.In this study,the size,number,and location of fibroids did not affect therapeutic efficacy or the complication rate of UAE.
4.The role of mitochondria in osteogenic, adipogenic and chondrogenic differentiation of mesenchymal stem cells.
Qianqian LI ; Zewen GAO ; Ye CHEN ; Min-Xin GUAN
Protein & Cell 2017;8(6):439-445
Mesenchymal stem cells (MSCs) are progenitors of connective tissues, which have emerged as important tools for tissue engineering due to their differentiation potential along various cell types. In recent years, accumulating evidence has suggested that the regulation of mitochondria dynamics and function is essential for successful differentiation of MSCs. In this paper, we review and provide an integrated view on the role of mitochondria in MSC differentiation. The mitochondria are maintained at a relatively low activity level in MSCs, and upon induction, mtDNA copy number, protein levels of respiratory enzymes, the oxygen consumption rate, mRNA levels of mitochondrial biogenesis-associated genes, and intracellular ATP content are increased. The regulated level of mitochondrial ROS is found not only to influence differentiation but also to contribute to the direction determination of differentiation. Understanding the roles of mitochondrial dynamics during MSC differentiation will facilitate the optimization of differentiation protocols by adjusting biochemical properties, such as energy production or the redox status of stem cells, and ultimately, benefit the development of new pharmacologic strategies in regenerative medicine.
Adipogenesis
;
physiology
;
Animals
;
Cell Differentiation
;
physiology
;
Chondrogenesis
;
physiology
;
Humans
;
Mesenchymal Stem Cells
;
cytology
;
metabolism
;
Mitochondria
;
genetics
;
metabolism
;
Mitochondrial Proteins
;
genetics
;
metabolism
;
Osteogenesis
;
physiology
;
RNA
;
genetics
;
metabolism
;
RNA, Messenger
;
genetics
;
metabolism
;
RNA, Mitochondrial
;
Reactive Oxygen Species
;
metabolism
5.Retrospective single center analysis:sutureless technique for neonates with total anomalous pulmonary venous connec-tion
Xiaohua LI ; Zewen CHEN ; Jimei CHEN ; Jian ZHUANG ; Yifan LI ; Jianzheng CEN ; Shusheng WEN ; Gang XU ; Qiang GAO ; Junfei ZHAO
Chinese Journal of Thoracic and Cardiovascular Surgery 2018;34(11):675-678
Objective To retrospectively analyse the outcomes following primary Sutureless technique used in our hospi-tal for neonates with total anomalous pulmonary venous connection(TAPVC)and sum up surgical operative experiences. Meth-ods Date were collected retrospectively in 42 neonates who underwent primary Sutureless technique for TAPVC between Janu-ary 2008 and December 2015. Cardiopulmonary bypass time,aortic clamped time,velocity of pulmonary veins and other relat-ed data were recorded during and after operation. Results There were 31 males and 11 females with median age of 8. 0 days old,of whom 25 were supracardiac TAPVC(59. 5%)and 17 were infracardiac TAPVC(40. 5%). After operation, 1 neonate died and none suffered from pulmonary vein obstruction(PVO). In follow-up period,there was 1 neonates suffered from PVO. Six neonates came back to hospital again because of septicemia,poor wound healing,bronchopneumonia and incomplete intesti-nal obstruction. Conclusion Sutureless technique is a wise surgical strategy for neonates with TAPVC for better outcomes and decreasing postoperative mortality rate and recurrence rate of PVO.