1.Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: An in vitro study
Ava NIKBIN ; Zahra DALILI KAJAN ; Mehran TARAMSARI ; Negar KHOSRAVIFARD
Imaging Science in Dentistry 2018;48(4):245-254
PURPOSE: To assess the effects of object position in the field of view (FOV) and application of a metal artifact reduction (MAR) algorithm on the diagnostic accuracy of cone-beam computed tomography (CBCT) for the detection of vertical root fractures (VRFs). MATERIALS AND METHODS: Sixty human single-canal premolars received root canal treatment. VRFs were induced in 30 endodontically treated teeth. The teeth were then divided into 4 groups, with 2 groups receiving metal posts and the remaining 2 only having an empty post space. The roots from different groups were mounted in a phantom made of cow rib bone, and CBCT scans were obtained for the 4 different groups. Three observers evaluated the images independently. RESULTS: The highest frequency of correct diagnoses of VRFs was obtained with the object positioned centrally in the FOV, using the MAR algorithm. Peripheral positioning of the object without the MAR algorithm yielded the highest sensitivity for the first observer (66.7%). For the second and third observers, a central position improved sensitivity, with or without the MAR algorithm. In the presence of metal posts, central positioning of the object in the FOV significantly increased the diagnostic sensitivity and accuracy compared to peripheral positioning. CONCLUSION: Diagnostic accuracy was higher with central positioning than with peripheral positioning, irrespective of whether the MAR algorithm was applied. However, the effect of the MAR algorithm was more significant with central positioning than with peripheral positioning of the object in the FOV. The clinical experience and expertise of the observers may serve as a confounder in this respect.
Artifacts
;
Bicuspid
;
Cone-Beam Computed Tomography
;
Dental Pulp Cavity
;
Diagnosis
;
Humans
;
In Vitro Techniques
;
Ribs
;
Tooth
;
Tooth Fractures
2.Diagnostic performance of stitched and non-stitched cross-sectional cone-beam computed tomography images of a non-displaced fracture of ovine mandibular bone
Farzane OSTOVARRAD ; Sadra Masali MARKIYEH ; Zahra Dalili KAJAN
Imaging Science in Dentistry 2023;53(4):375-381
Purpose:
This study assessed the diagnostic performance of stitched and non-stitched cross-sectional cone-beam computed tomography (CBCT) images of non-displaced ovine mandibular fractures.
Materials and Methods:
In this ex vivo study, non-displaced fractures were artificially created in 10 ovine mandibles (20 hemi-mandibles) using a hammer. The control group comprised 8 hemi-mandibles. The non-displaced fracture lines were oblique or vertical, <0.5 mm wide, 10-20 mm long, and only in the buccal or lingual cortex. Fracture lines in the ramus and posterior mandible were created to be at the interface or borders of the 2 stitched images. CBCT images were obtained from the specimens with an 80 mm × 80 mm field of view before and after fracture induction. OnDemand software (Cybermed, Seoul, Korea) was used for stitching the CBCT images. Four observers evaluated 56 (28 stitched and 28 non-stitched) images to detect fracture lines. The diagnostic performance of stitched and non-stitched images was assessed by calculating the area under the receiver operating characteristic curve (AUC). Sensitivity and specificity values were also calculated (alpha=0.05).
Results:
The AUC was calculated to be 0.862 and 0.825 for the stitched and non-stitched images, respectively (P=0.747). The sensitivity and specificity were 90% and 75% for the non-stitched images and 85% and 87% for the stitched images, respectively. The inter-observer reliability was shown by a Fleiss kappa coefficient of 0.79, indicating good agreement.
Conclusion
No significant difference was found in the diagnostic performance of stitched and non-stitched cross-sectional CBCT images of non-displaced fractures of the ovine mandible.
3.A comparative study of metal artifacts from common metal orthodontic brackets in magnetic resonance imaging.
Zahra DALILI KAJAN ; Jalil KHADEMI ; Ahmad ALIZADEH ; Yasamin BABAEI HEMMATY ; Zahra ATRKAR ROUSHAN
Imaging Science in Dentistry 2015;45(3):159-168
PURPOSE: This study was performed to compare the metal artifacts from common metal orthodontic brackets in magnetic resonance imaging. MATERIALS AND METHODS: A dry mandible with 12 intact premolars was prepared, and was scanned ten times with various types of brackets: American, 3M, Dentaurum, and Masel orthodontic brackets were used, together with either stainless steel (SS) or nickel titanium (NiTi) wires. Subsequently, three different sequences of coronal and axial images were obtained: spin-echo T1-weighted images, fast spin-echo T2-weighted images, and fluid-attenuated inversion recovery images. In each sequence, the two sequential axial and coronal images with the largest signal-void area were selected. The largest diameters of the signal voids in the direction of the X-, Y-, and Z-axes were then measured twice. Finally, the mean linear values associated with different orthodontic brackets were analyzed using one-way analysis of variation, and the results were compared using the independent t-test to assess whether the use of SS or NiTi wires had a significant effect on the images. RESULTS: Statistically significant differences were only observed along the Z-axis among the four different brands of orthodontic brackets with SS wires. A statistically significant difference was observed along all axes among the brackets with NiTi wires. A statistically significant difference was found only along the Z-axis between nickel-free and nickel-containing brackets. CONCLUSION: With respect to all axes, the 3M bracket was associated with smaller signal-void areas. Overall, the 3M and Dentaurum brackets with NiTi wires induced smaller artifacts along all axes than those with SS wires.
Artifacts*
;
Bicuspid
;
Magnetic Resonance Imaging*
;
Mandible
;
Nickel
;
Orthodontic Brackets*
;
Orthodontic Wires
;
Stainless Steel
;
Titanium
4.Periosteal reaction as a crucial radiographic finding for desmoplastic fibroma of the jaw bone in children: A case report
Safa MOTEVASSELI ; Zahra YOUSEFI ; Zahra Dalili KAJAN ; Reza MODANLOU ; Niousha ROUDBARI
Imaging Science in Dentistry 2022;52(3):319-326
This report presents the case of a 5-year-old boy with a hard swelling on the right side of the mandible body. An important point of this case is that the primary imaging finding was fine spicules in the inferior border of the mandible on panoramic radiography without significant changes in bone density. Cone-beam computed tomography views revealed a lytic lesion on the lingual side of the right mandibular body with the destruction of the lingual cortex and periosteal reaction from the midline to the first molar area. Careful attention to this radiographic finding in the primary stage in the absence of other significant imaging findings, particularly in children, could result in the early diagnosis of desmoplastic fibroma. Therefore, a better prognosis can be expected following early surgicaltreatment.
5.The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries.
Zahra Dalili KAJAN ; Reza TAYEFEH DAVALLOO ; Mayam TAVANGAR ; Fatemeh VALIZADE
Imaging Science in Dentistry 2015;45(2):81-87
PURPOSE: Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. MATERIALS AND METHODS: Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying "Sharpening 2" and "Noise Reduction" processing options to the original images; (2) applying the "Magnification 1:3" option to the image obtained in the first step; (3) enhancing the original images by using the "Diagonal/" option; (4) reviewing the changes brought about by the third step of image processing and then, applying "Magnification 1:3"; (5) applying "Sharpening UM" to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying "Magnification 1:3." Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. RESULTS: The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). CONCLUSION: This study shows that the application of "Sharpening UM" along with the "Magnification 1:3" processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.
Dental Caries*
;
Humans
;
Image Enhancement
;
Noise*
;
Radiography, Dental, Digital
;
Tooth
6.Frequency of different maxillary sinus septal patterns found on cone-beam computed tomography and predicting the associated risk of sinus membrane perforation during sinus lifting.
Ali KHALIGHI SIGAROUDI ; Zahra DALILI KAJAN ; Shabnam RASTGAR ; Hamid NESHANDAR ASLI
Imaging Science in Dentistry 2017;47(4):261-267
PURPOSE: Analyzing different patterns of maxillary sinus septa in cone-beam computed tomography (CBCT) images and predicting maxillary sinus membrane perforations. MATERIALS AND METHODS: In this cross-sectional study, CBCT images of 222 patients ranging from 20 to 81 years old were evaluated. One hundred fifty-two patients (93 females and 59 males) who had maxillary sinus septa in axial views were included in this study. Cross-sectional images were used to determine classifications of sinus septa and the risk of membrane perforation using a method modified from Al-Faraje et al. Variables of sex, age, and dental status were considered. Chi-squared and Kruskal-Wallis tests were used for data analysis (P < .05). RESULTS: In this study, 265 maxillary sinus septal patterns were found. The mean age of the patients was 44.1±14.7 years old. The Class I and VII-div II patterns had the greatest and least prevalence, respectively. Furthermore, there was a significant relationship between the location of septa and the frequency of membrane perforation risk (P < .05). In this study, the relationship of different patterns of septa with dental status did not differ significantly (P>0.05). CONCLUSION: A higher prevalence of moderate risk of membrane perforation in the molar region relative to the premolar region was observed. Furthermore, maxillary sinus septa occur most frequently in the molar region, demonstrating the importance of paying attention to this region during sinus lift surgery. This study did not show any relationship between tooth loss and the presence of septa.
Bicuspid
;
Classification
;
Cone-Beam Computed Tomography*
;
Cross-Sectional Studies
;
Female
;
Humans
;
Lifting*
;
Maxillary Sinus*
;
Membranes*
;
Methods
;
Molar
;
Oral Surgical Procedures
;
Prevalence
;
Statistics as Topic
;
Tooth Loss
7.Comparison of high-resolution and standard zoom imaging modes in cone beam computed tomography for detection of longitudinal root fracture: An in vitro study.
Mehran TARAMSARI ; Zahra Dalili KAJAN ; Parinaz BASHIRZADEH ; Fatemeh SALAMAT
Imaging Science in Dentistry 2013;43(3):171-177
PURPOSE: The purpose of this study was to compare the efficacy of two imaging modes in a cone beam computed tomography (CBCT) system in detecting root fracture in endodontically-treated teeth with fiber posts or screw posts by selecting two fields of view. MATERIALS AND METHODS: In this study, 78 endodontically-treated single canal premolars were included. A post space was created in all of them. Then the teeth were randomly set in one of 6 artificial dental arches. In 39 of the 78 teeth set in the 6 dental arches, a root fracture was intentionally created. Next, a fiber post and a screw post were cemented into 26 teeth having equal the root fractures. High resolution (HiRes) and standard zoom images were provided by a CBCT device. Upon considering the reconstructed images, two observers in agreement with each other confirmed the presence or absence of root fracture. A McNemar test was used for comparing the results of the two modes. RESULTS: The frequency of making a correct diagnosis using the HiRes zoom imaging mode was 71.8% and in standard zoom was 59%. The overall sensitivity and specificity in diagnosing root fracture in the HiRes mode were 71.79% and 46.15% and in the standard zoom modes were 58.97% and 33.33%, respectively. CONCLUSION: There were no significant differences between the diagnostic values of the two imaging modes used in the diagnosis of root fracture or in the presence of root canal restorations. In both modes, the most true-positive results were reported in the post space group.
Bicuspid
;
Cone-Beam Computed Tomography
;
Dental Arch
;
Dental Pulp Cavity
;
Intention
;
Nerve Fibers, Myelinated
;
Sensitivity and Specificity
;
Tooth
;
Tooth Fractures
;
Tooth, Nonvital