1. Clinical value of echocardiography in differential diagnosis of segmental wall motion abnormalities in coronary heart disease
Qixun MAO ; Lifei SHAO ; Yang LIU ; Wen ZHU
Chinese Journal of Primary Medicine and Pharmacy 2019;26(15):1838-1841
Objective:
To explore the clinical value of echocardiography in differential diagnosis of segmental wall motion abnormalities in coronary heart disease(CHD), and to provide help for clinical treatment.
Methods:
From January 2017 to November 2018, 56 patients with segmental abnormal wall motion of CHD in Yuyao People's Hospital of Zhejiang Province were selected in the study.All patients were diagnosed by echocardiography and coronary angiography.The diagnostic coincidence rate, specificity, sensitivity, false negative rate, false positive rate and accuracy of echocardiography were evaluated.
Results:
Coronary angiography showed abnormal segmental wall motion in 56 patients, with 100.00% anastomosis rate.Echocardiography revealed abnormal segmental wall motion in 54 patients with CHD, 2 patients showed normal segmental wall motion, anastomosis rate was 96.43%.There was no statistically significant difference between the two diagnostic methods(χ2=0.635,
2.Efficacy comparison of 0.01% atropine eye drops combined with defocus incorporated multiple segment spectacle lenses or highly aspherical lenslets in delaying the progression of myopia in adolescents
Xiang LI ; Xiaoli MAO ; Shuangshuang YAO
International Eye Science 2024;24(10):1640-1644
AIM: To compare the effects of defocus incorporated multiple segments(DIMS)lens with highly aspherical lenslets(HAL)on delaying the progression of myopia in adolescents.METHODS: Clinical randomized controlled study. Totally 301 students aged 7-12 who underwent optometry in our hospital from January 2021 to June 2023 were randomly divided into two groups. The first group consisted of 154 patients who were fitted with DIMS lenses(DIMS group). In the second group, 147 cases were fitted with HAL(HAL group). Both groups used 0.01% atropine eye drops to control myopia and all students wore glasses for more than 12 h every day. The spherical equivalent(SE)and axial length(AL)after rapid mydriasis were recorded. The data of the right eyes were taken, and the results after fitting for 12 mo were compared between the two groups.RESULTS: Multiple linear regression analysis showed that baseline age was significantly correlated with the changes of SE and AL(all P<0.01). After controlling baseline variables, the adjusted changes in SE for 12 mo after wearing glasses in the DIMS group and HAL group were -0.41±0.18 and -0.34±0.13 D, respectively(P<0.001); the changes of AL in the DIMS group and HAL group were 0.31±0.08 and 0.27±0.06 mm, respectively(P<0.001). Patients were divided into younger group(7-9 years old)and older group(10-12 years old). The changes in SE(t=2.250, P=0.025)and AL(t=3.120, P=0.002)of the younger group who wearing DIMS lens were greater than those with HAL after 12 mo, and the same was true in the older group(t=5.931, 5.033, both P<0.001).CONCLUSION: Under the condition of combined use of 0.01% atropine eye drops, HAL is more effective than DIMS lens in controlling myopia diopter and AL of adolescents.
3. Resuscitative effect of aortic balloon occlusion on traumatic cardiac arrest in swine
Jiefeng XU ; Peng SHEN ; Senlin XIA ; Yuzhi GAO ; Shaoyun LIU ; Anyu QIAN ; Zilong LI ; Moli WANG ; Mao ZHANG
Chinese Journal of Trauma 2019;35(10):942-947
Objective:
To investigate the resuscitation effect of aortic balloon occlusion (ABO) on the traumatic cardiac arrest (TCA) in swine.
Methods:
Twenty-seven male domestic swine weighing (32.7±3.8)kg were utilized. After 40% of estimated blood volume was removed within 20 minutes, the animals were subjected to 5 minutes of untreated ventricular fibrillation and then 5 minutes of cardiopulmonary resuscitation. Additionally, fluid resuscitation was initiated coincident with the beginning of cardiopulmonary resuscitation. The animals were randomly divided into model group (
4.Application of automated breast volume scanner and mammography in differentiation of small breast lesions with BI-RADS-US 4.
Huan WEN ; Jidong XIAO ; Yuanquan ZHOU ; Fang HE ; Yuyao MAO
Journal of Central South University(Medical Sciences) 2018;43(10):1131-1136
To evaluate the value of automatic breast volume scanner (ABVS) and mammography (MG) in differential diagnosis for small breast lesions with breast imaging reporting and data system ultrasound (BI-RADS-US) 4.
Methods: ABVS and MG were performed for 103 patients with 109 breast lesions, which were classified as BI-RADS-US 4 by conventional ultrasound (US). Postoperative pathological diagnosis served as gold standard. The diagnostic efficacy for US, US combined with MG, US combined with ABVS and the combination of three methods were compared.
Results: The sensitivity of US, US combined with MG, US combined with ABVS and the combination of three methods were 85.5%, 86.8%, 94.7% and 96.0%, respectively. The specificity for them were 66.7%, 69.7%, 81.8% and 84.9%, respectively. The accuracy for them were 79.8%, 81.6%, 90.8% and 92.7%, respectively. The area under the receiver operating characteristic (ROC) curve (AUC) for them were 0.76, 0.78, 0.88 and 0.90, respectively. The accuracy and AUC for US combined with ABVS in differential diagnosis of BI-RADS-US 4 small breast lesions were significantly higher than those of US and US combined with MG (P<0.05). There was no significant difference in sensitivity and specificity among these 3 groups (P>0.05). No significant difference was found in sensitivity, specificity, accuracy, and AUC between US combined with ABVS and the combination of three methods (P>0.05).
Conclusion: Combination of US with ABVS can improve the diagnostic efficacy of conventional US in differential diagnosis for BI-RADS-US 4 small breast lesions, and it is superior to US combined with MG.
Breast
;
diagnostic imaging
;
Breast Neoplasms
;
diagnostic imaging
;
Female
;
Humans
;
Mammography
;
Reproducibility of Results
;
Sensitivity and Specificity
;
Ultrasonography, Mammary