1.Effects of electro-acupuncture on gastric emptying and Fos expression in the neuron of vagal-solitary complex of rat bulbus after LPS stimulation
Ming QIN ; Yuxin HUANG ; Jingjie WANG ; Qi YANG ; Zhiren RAO
Medical Journal of Chinese People's Liberation Army 2006;31(7):651-653
Objective To investigate the effects of electro-acupuncture on gastric emptying and Fos expression in the neuron of vagal-solitary complex (VSC) of rat bulbus after lipopolysaccharide (LPS) intraperitoneal injection (i.p.). Methods 40 male SD rats were randomly assigned to 4 groups: control group, LPS i.p. group, LPS i.p. plus electro-acupuncture at Tsusanli point group and LPS i.p. plus electro-acupuncture at non-meridian-non-acupoint group, 10 rats for each group. Immunohistochemical techniques were used to detect the Fos expression in VSC. The animal's gastric emptying was measured by phenol red method. Results The rats with gastric emptying decreased greatly to (20.7±4.5)% 2.5 hours after LPS injection, and Fos-positive neurons were significantly found in VSC (83.2±6.6) compared with control group. However, in the group of LPS i.p. plus electro-acupuncture at Tsusanli point, the gastric emptying was up-regulated to (44.1±6.2)%, and the expression of Fos -positive neurons were down-regulated to (37.9±3.8) compared with LPS i.p. group. No significant difference was found between the group of LPS i.p. plus electro-acupuncture at non-meridian-non-acupoint and the group of LPS i.p. Conclusion LPS i.p. can retard the gastric motility in rats, electro-acupuncture at Tsusanli point may well regulate the function in LPS model rats. This function may be connected with its protective effects on Fos immunoreactive neurons activity in VSC of rat bulbus.
2.Analysis of Early Monitoring for Heart Damage Caused by Anthracyclines Chemotherapy Drugs after Breast Cancer Surgery
Yuxin QI ; Jiao LIU ; Yingna HE ; Yanqing REN
China Pharmacy 2017;28(17):2356-2359
OBJECTIVE:To investigate the early changes of ECG,cTnⅠ,LDH,α-HBDH and CKMB in patients with anthra-cyclines chemotherapy-induced heart damage after breast cancer surgery,and to explore their significances in the diagnosis of early heart damage. METHODS:Medical information of 152 cases of anthracyclines chemotherapy after breast cancer surgery in our hos-pital during Jan. 2015-Jun. 2016 were analyzed retrospectively. According to diagnosis criteria of drug-induced cardiotoxicity,the occurrence of heart damage was evaluated during hospitalization and 1-year follow-up. According to evaluation results,those pa-tients were divided into heart damage group(50 cases)and control group(102 cases). The early changes of ECG,cTnⅠ,LDH, CKMB and α-HBDH were analyzed before chemotherapy(T0),24 h after first chemotherapy(T1),24 h after second chemothera-py(T2),24 h after forth chemotherapy. RESULTS:At T1,T2,T3,the proprotion of ECG abnormalities in heart damage group was significantly higher than control group;the serum levels of cTnⅠ,LDH,CKMB andα-HBDH in heart damage group were signifi-cantly higher than control group, with statistical significance (P<0.01). CONCLUSIONS:For anthracyclines chemotherapy drugs-induced heart damage after breast cancer surgery,early regular monitoring of ECG,cTnⅠ,LDH,CKMB and α-HBDH can improve the efficiency of early diagnosis of heart damage,and improve prognosis.
3.Role of thoracic electrical bioimpedance monitoring in the evaluation of cardiac function in peritoneal dialysis patients
Xiao JIANG ; Yuxin SHEN ; Zhiwei HU ; Min ZHAO ; Xiangming QI ; Yonggui WU
Chinese Journal of Nephrology 2013;29(9):655-659
Objective To evaluate the effectiveness of thoracic electrical bioimpedance(TEB)in monitoring the cardiac function of peritoneal dialysis patients.Methods One hundred and one patients with continuous ambulatory peritoneal dialysis (CAPD) and 30 healthy persons (control group)were included in the study.Thoracic electrical bioimpedance (TEB) noninvasive hcmodynamic monitoring and echocardiography were taken to analyze the correlation between indexes.Results Echocardiography showed that left atrial diameter (LAD),left ventricular end diastolic diameter (LVDd),left ventricular end systolic diameter (LVDs),interventricular septal thickness (IVST),interventricular septal thickness (PAP),left ventricle weight index (LVMI) of CAPD group were higher than that of the control group (all P < 0.05),early and late wave of mitral valve flow (E/A) of CAPD group was lower than that of control group (P < 0.05).TEB monitoring showed that cardiac output (CO),stroke volume (SV),acceleration index (ACI),ejection fraction (EF),velocity index (Ⅵ) of CAPD group were significantly lower than that of control group (all P < 0.01),systolic time ratio (STR),SVR,TFC of CAPD group were significantly higher than that of control group (P < 0.01).Correlation analysis show that left ventricular ejection fraction (LVEF) was negatively correlated with BNP (r =-0.467,P < 0.01),LVMI was positively correlated with BNP (r=0.416,P < 0.01),PEP,STR and TFC were positively correlated with BNP (r =0.404,P < 0.01; r =0.572,P < 0.01; r=0.471,P < 0.01),EF was negatively correlated with BNP (r =-0.664,P < 0.01).Correlation analysis between echocardiogaphy and TEB monitoring index showed there was significant correlation between EF and LVEF (r =0.451,P < 0.01),SVR and TFC were positively correlated with LVMI (r =0.232,P < 0.05; r =0.284,P < 0.05),SV was positively correlated with E/A (r =0.285,P < 0.05),pre-ejection period (PEP) and STR were negatively correlated with LVEF (r =-0.389,P < 0.01; r =-0.446,P < 0.01),TFC was positively correlated with LAD (r=0.279,P < 0.05).Conclusion TEB monitoring can accurately evaluate the cardiac function with the advantage of dynamic monitoring and simple operation.It can partly replace the echocardiography test.
4.Sonographic assessment for breast augmentation by repeated injection of low volume of autologous fat
Hongyan WANG ; Yuxin JIANG ; Hua MENG ; Keming QI ; Zhifei LIU ; Yuan YU
Chinese Journal of Medical Aesthetics and Cosmetology 2010;16(2):90-93
Objective To assess the absorbance rate of the fat after the operation of breast augmentation of the repeated injection of low volume, using ultrasonic imaging method. Methods Thirty three patients were injected with low volume of autologous fat (50-60 ml per time) to bilateral breasts for 1-5 times and breast sonographic examination was performed to evaluate the grafted fat tissues. The thickness of the retromammary fat layer before and after each injection was measured to calculate the absorbance index. Results The 264 points of breast were measured in this study. The fat was distributed in the retro-mammary fat layers at 224 points of the breast and in the pectoralis major muscle layer at 32 points of the breast, and the others distributed in the mammary gland layer.The average thickness of the retromammary fat layer increased gradually from 0.2 cm before the first operation to 1. 0 cm after the fifth operation. The average absorbance index one month after each operation was 34 %-66 %. Conclusion The present study demonstrates that breast augmentation by repeated autologous fat graft with low volume injection at each time is applicable and satisfactory and that breast ultrasound is an accurate and simple method to e-valuate the absorbance index.
5.Ultrasonographic features in complications of cosmetic augmentation with autologous fat obtained by liposuction
Hongyan WANG ; Yuxin JIANG ; Hua MENG ; Qingli ZHU ; Qing DAI ; Keming QI
Chinese Journal of Ultrasonography 2010;19(5):423-426
Objective To evaluate the ultrasonographic (US) features and evolution of breast fat necrosis after cosmetic augmentation with autologous fat obtained by liposuction, to help distinguish fat necrosis from more ominous breast masses. Methods Breast sonography was performed on 38 patients underwent bilateral breast augmentation by autologous fat injection to evaluate the grafted fat tissues in interval of 3-6 month after the operation. Observations in follow up sonography included the sizes,positions, shape,echogenicity,margin features, calcifications and evolutions of the suspicious nodules in the breasts. Results Seventy-six nodules occurred in 25 of the 38 patients were detected after the fat graft. Among the 76 nodules,52 were cystic(68. 4%) ,8 were complex(10. 5%) and 16 were solid(21.1%). The analysis of the predominant features of the nodules sonographic appearances were as follows: all the nodules had no flow signal, 66 (86. 8%) had clear margins,54(71. 1%) had regular shapes,52 were cystic(68. 4%) ,63(82. 9% ) had no calcifications, 10(13. 2%) had egg-like calcifications,74(97. 4% ) had no halo,and the positions of the solid components in 8 complex nodules move following the change of the detected body position. There were 7 nodules with fat necrosis removed surgically and confirmed by pathology. Conclusions Breast ultrasound is an accurate and simple method to follow up the temporal changes of the fat nodules after autologous fat injection. It may help to avoid unnecessary biopsies.
6.Method for calculating the blood concentration of isoflurane with the inspired and expired concentrations during laparoscopic surgery
Huimin BU ; Qi WU ; Weifu LEI ; Jun NIU ; Yuxin CHEN ; Enyu LIU
Chinese Journal of Current Advances in General Surgery 2004;0(05):-
Objective: To estimate the blood concentration of isoflurane with the inspired andexpired concentrations during laparoscopic surgery. Methods: 2 sections were divided in this experiment: section 1:23 adult patients (ASA I~II)were received abdominal surgeries,of whom,12 patients for non-laparoscopic surgeries and the others for laparoscopic surgeries. Central venous blood samples were collected for gas chromatography determination 20, 40, 60, 80 min after inhalating isoflurane . We could receive two different F value (the fraction of uptake of isoflurane)through the formula. Section 2: 27 patients were recruited for abdominal surgeries, 13 for laparoscopic surgeries and the others for non-laparoscopic surgeries. All of the processes were the same as the former. Then we confirm the results obtained from section1. Results: The F was 0.52 in the laparoscopic surgeries and 0.44 in the nonlaparoscopic surgeries. In the laparoscopic surgeries, the bias (MDPE) was 17% , accuracy (MDAPE)was 22.88% and the wobble was 11.7% .The correlation coefficient (r)was 0.83. In the nonlaparoscopic surgeries, the MDPE was 5.37% , the MDAPE was 16.02% , the wobble was 15.86% .The correlation coefficient was 0.90. Conclusion: The formula could be used in abdominal surgeries to evaluate the concentration of isoflurane according to the clinical standard of MDPE
7.Influence of sleep deprivation on serum interleukin-1β level in rats with coronary atherosclerosis
Li TAN ; Qi HUANG ; Demei LI ; Lingling CHEN ; Yuxin ZHANG ; Zhixiao WANG
Chinese Journal of cardiovascular Rehabilitation Medicine 2014;23(1):1-5
Objective: To explore influence of sleep deprivation (SDP) on serum interleukin-1β (IL-1β) level in rats with coronary atherosclerosis (CAS). Methods: A total of 96 healthy SD rats were randomly and equally divided into normal control group, CAS group, SDP group and SDP + CAS group according to number table; rats in CAS group and SDP + CAS group were fed with high cholesterol diet to establish CAS animal model; SDP group and SDP + CAS group received SDP through small platform with water environment. Radioimmunoassay was used to measure serum concentration of IL-1β; and serum concentrations of total cholesterol (TC), triglyceride (TG), high density lipoprotein-cholesterol (HDL-C) and low density lipoprotein-cholesterol (LDL-C) were measured respectively; above indexes were compared among four groups. Results: (1) Compared with serum IL-1β level of normal control group, there were significant increase in SDP group, CAS group and SDP + CAS group[(13.33±3.20) ng/L vs. (14.40±4.41) ng/L vs. (22.21±5.94) ng/L vs. (30.17±7.45) ng/L] (P<0.05~<0.01); (2) Levels of TC, TG and LDL-C in CAS group and SDP + CAS group were significantly higher, level of HDL were significantly less than those of normal control group and SDP group (P<0.05~<0.01), levels of above indexes in SDP + CAS group were significantly higher or less than those of CAS group (P<0.05 all). Conclusion: Sleep deprivation can significantly heighten serum interleukin-1β level and total cholesterol, triglyceride, low density lipoprotein-cholesterol levels, decrease HDL level in rats with coronary atherosclerosis or sleep deprivation.
8.Ultrasonographic analysis of mass-type cornual pregnancy
Na, SU ; Qing, DAI ; Yuxin, JIANG ; Zhenhong, QI ; Meng, YANG ; Yao, WEI
Chinese Journal of Medical Ultrasound (Electronic Edition) 2014;(9):749-754
Objective To summarize the sonographic features and differential diagnosis points of mass-type cornual pregnancy. Methods The sonographic ifndings of 23 pathological proven mass-type cornual pregnancy cases enrolled in PUMCH from 2011 January to 2013 January were retrospectively analyzed. Results All pathological proven mass-type cornual pregnancy were located at one corner of the uterus presenting as a heterogenous outward mass. Well-deifned margins were found in 20 cases, and interstitial-line signs were found in 15 cases. The surrounding muscle thickness is 0.1-0.3 cm. Typical hyperechoic villi were found on sonography in cases with bloodβ-hCG>20 000 IU/L. On Doppler, the lesion showed abundant peripheral vascularity with low resistance in 22 cases, 9 lesions also showed abundant internal vascularity. Among 23 mass-type cornual pregnancy cases, 7 cases were misdiagnosed as gestational trophoblastic neoplasia (GTN) due to the similar sonographic characteristics including mixed-echo and abundant vascularity with low resistance. Sixteen cases were diagnosed by ultrasound preoperatively, with featured sonographic signs including mass located in the endometrial extension line;clear margin;peripheral vascularity;or detection of interstitial-line sign and typical villus. Conclusions Mass-type cornual pregnancy may be correctly diagnosed according to the location, boundary of the mass and the distribution of blood flow combining with clinical manifestation and bloodβ-hCG level. Transvaginal sonography could play an important role in diagnosis of cornual pregnancy.
9.Application research on low radiation dose and low concentration of contrast medium of energy spectrum CT in the imaging of the coronary arteries
Xiaoxia CHEN ; Chunling MA ; Yuxin LEI ; Shuanhong LU ; Xin TIAN ; Qian TIAN ; Zhanli REN ; Qi YANG
Journal of Practical Radiology 2016;32(8):1285-1288
Objective To explore the application of low dose of radiation combined with low concentration of contrast medium in the energy spectrum CT of the coronary artery angiography.Methods 60 patients with suspected diagnosis of coronary heart disease were randomly divided into A,B two groups,30 cases in each group.Group A with 350 mg I/mL contrast agent,undergoing conventional CT scanning;Group B using 300 mg I/mL contrast agent,the gems energy spectrum CT scanning with low-dose.Two groups both adopted forward-looking heart switch control scanning mode.After scanning,group A reconstructed conventional images of 40% ASiR sequence,group B rebuilded axial surface images of single energy 65 keV and 40% ASiR sequence,all the reconstruction images were introduced to AW4.6 workstations used for analysis.Double-blind subjective rating was done by two experienced doctors to measure CT values and SD of aortic sinus (AS),left main (LMA),the left anterior descending branch proximal (LAD-p),left circumflex branch proximal (LCX-p), right coronary artery proximal (RCA-p)and pericardial fat,AS the noise (SD),to calculate the signal-to-noise ratio (SNR)and contrast to noise ratio (CNR),to calculate the effective doses of radiation(ED)by recording CTDI and DLP,and to record iodine intake.By using two independent samples t test to compare two groups of patients’the effective radiation doses,iodine intake,the average CT value,SD,SNR and CNR.Results The subjective image quality score differences and coronary measuring section CT values between the two groups had no statistical significance.In the aspects of effective radiation dose,group B reduced about 29% compared to group A,the difference was statistically significant.Iodine intake in group B decreased about 16% than in group A.Conclusion In coronary artery CT imaging, spectral scanning with low dose of radiation and reconstruction images with single energy can effectively reduce the radiation dose and iodine intake,at the same time it can obtain the approximate image quality like conventional scanning.
10.Personalized Energy Agreement Application in CT Scan of the Upper Abdomen
Xiaoxia CHEN ; Chunling MA ; Yuxin LEI ; Xin TIAN ; Zhanli REN ; Qian TIAN ; Qi YANG
Chinese Journal of Medical Imaging 2015;(12):955-958,960
PurposeTo explore the feasibility of personalized energy spectrum scanning in upper abdomen CT by comparing the image quality and radiation dose of optimizing choice spectrum scanning protocol with conventional 120 kVp scan.Material and Methods Sixty patients undergoing abdominal CT scan with and without contrast enhancement were prospectively collected and randomly assigned into two groups. Group A (30 patients) underwent conventional 120 kVp scan and spectral enhancement scanning; group B (30 patients) underwent spectrum scan and 120 kVp enhancement scanning. Spectral scanning protocol was based on individual choice with conventional 120 kVp NI10-5 mm average mAs scan for every patient. The CT dose index of volume (CTDIvol) and effective dose (ED) during non-contrast phase and portal venous phase were recorded. The CT value, standard deviation (SD), signal noise ratio (SNR) and contrast noise ratio (CNR) were measured in the liver parenchyma, spleen parenchyma and portal venous trunk.Results The CTDIvol and ED of spectrum scanning were less than 120 kVp scan but there was no statistical difference (P>0.05). The SD of group B GSI imaging was less than group A 120 kVp (P<0.05), while the SNR was greater than group A. The SD of group A GSI portal venous phase in the liver, spleen and portal vein was less than group B 120 kVp (P<0.05).ConclusionThe optimized energy spectrum scanning protocol can reduce radiation dose with quality of single energy image from the energy spectrum equal to or better than the conventional 120 kVp scanning protocol. Personalized energy spectrum scan protocol provides multi-parameter diagnosis and multi-application platform and can be used routinely in the upper abdomen scan.