1.Simultaneous Axillo-Axillary Crossover Bypass Grafting and Off-Pump CABG Using Bilateral Internal Thoracic Arteries in a Patient with Severe Atherosclerosis in Both the Ascending Aorta and Proximal Left Subclavian Artery
Yutaka Iba ; Sunao Watanabe ; Takehide Akimoto ; Kouhei Abe ; Hitoshi Koyanagi
Japanese Journal of Cardiovascular Surgery 2004;33(3):158-161
Combined surgery for left Subclavian artery revascularization and CABG was performed in a 74-year-old man with diabetes mellitus. The preoperative coronary angiogram showed critical stenoses in all three major branches, and arteriography revealed obstruction at the left proximal subclavian artery. Severe atherosclerotic calcification was acknowledged circumferentially in the ascending aorta and in the aortic arch. For this patient axillo-axillary crossover bypass grafting was performed first using and expanded PTFE graft, followed subsequently by off-pump CABG using all in situ grafts (right internal thoracic artery-left anterior descending artery (RITA-LAD), left internal thoracic artery-diagonal branch (LITA-diagonal branch), gastroepiploic artery-right coronary artery (GEA-RCA)). Postoperative recovery was smooth, with disappearance of significant pressure difference between both arms (preoperatively, 46mmHg). An angiogram on the 7th postoperative day showed a widely patent axillo-axillary bypass graft along with good flow of all three coronary grafts, in which LITA was visualized well through the axillo-axillary bypass graft. For complex atherosclerotic disease of the proximal aorta and incipient portion of neck vessels associated with severe coronary sclerosis, this technique is a suitable option.
2.A “Back Light System” for Identification of Sites for Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Solid Pancreatic Masses: A Prospective, Randomized Study with a Crossover Design
Ryo HARADA ; Hironari KATO ; Soichiro FUSHIMI ; Hirofumi INOUE ; Daisuke UCHIDA ; Yutaka AKIMOTO ; Takeshi TOMODA ; Kazuyuki MATSUMOTO ; Yasuhiro NOMA ; Naoki YAMAMOTO ; Shigeru HORIGUCHI ; Koichiro TSUTSUMI ; Hiroyuki OKADA
Clinical Endoscopy 2019;52(4):334-339
BACKGROUND/AIMS: We applied a back light system (BLS) with a magnifying glass to improve the ability to assess the adequacy of specimen sampling using endosonography. We conducted this study to evaluate the efficacy of the BLS in sampling of specimens by endoscopic ultrasound-guided fine needle aspiration of solid pancreatic masses. METHODS: This was a prospective, randomized, crossover, single-center clinical trial. An endosonographer evaluated adequacy on gross visual inspection and identified whitish specimen sampling sites with and without the BLS according to a randomization sequence in the first and second passes with a 25-G needle. On cytological evaluation, the presence of well-defined pancreatic ductal epithelium was evaluated by a cytopathologist who was blinded to any clinical information. RESULTS: A total of 80 consecutive patients were eligible during the study period. Adequacy was observed for 52 specimens (65%) with the BLS and 54 (68%) without the BLS (p=0.88). In assessment of specimen adequacy on gross examination, only fair agreement was observed both with and without BLS (kappa score 0.40 and 0.29, respectively). CONCLUSIONS: The BLS did not influence the ability to identify specimen sampling sites or reliable assessment of specimen site adequacy using gross visual inspection.
Biopsy, Fine-Needle
;
Cross-Over Studies
;
Endoscopic Ultrasound-Guided Fine Needle Aspiration
;
Endosonography
;
Epithelium
;
Glass
;
Humans
;
Needles
;
Pancreatic Ducts
;
Pancreatic Neoplasms
;
Prospective Studies
;
Random Allocation