1.Cervical Symmetric Dumbbell Ganglioneuromas Causing Severe Paresis.
Akira HIOKI ; Kei MIYAMOTO ; Yoshinobu HIROSE ; Yusuke KITO ; Kazunari FUSHIMI ; Katsuji SHIMIZU
Asian Spine Journal 2014;8(1):74-78
We report an extremely rare case with bilateral and symmetric dumbbell ganglioneuromas of the cervical spine in an elderly patient. A 72-year-old man came by ambulance to our hospital due to progressive incomplete paraplegia. Magnetic resonance imaging demonstrated bilateral symmetric dumbbell tumors at the C1/2 level. We performed total resection of the intracanalar tumor, aiming at complete decompression of the spinal cord, and partial and subtotal resection of foraminal outside portions. Histopathological examination of the surgical specimen indicated the tumor cells to be spindle cells with the presence of ganglion cells and no cellular pleomorphism, suggesting a diagnosis of ganglioneuroma. Although the surgery was not curative, the postoperative course was uneventful and provided a satisfactory outcome. This is the fourth known case of cervical ganglioneuromas of the bilateral symmetric dumbbell type.
Aged
;
Ambulances
;
Decompression
;
Diagnosis
;
Ganglion Cysts
;
Ganglioneuroma*
;
Humans
;
Magnetic Resonance Imaging
;
Paraplegia
;
Paresis*
;
Spinal Cord
;
Spine
2.Comparison of 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma using endoscopic ultrasound fine-needle aspiration
Mitsuru OKUNO ; Keisuke IWATA ; Tsuyoshi MUKAI ; Yusuke KITO ; Takuji TANAKA ; Naoki WATANABE ; Senji KASAHARA ; Yuhei IWASA ; Akihiko SUGIYAMA ; Youichi NISHIGAKI ; Yuhei SHIBATA ; Junichi KITAGAWA ; Takuji IWASHITA ; Eiichi TOMITA ; Masahito SHIMIZU
Clinical Endoscopy 2024;57(3):364-374
Background/Aims:
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) using a 19-gauge needle is an efficient sampling method for the diagnosis of lymphadenopathy. This study compared 19-gauge conventional and Franseen needles for the diagnosis of lymphadenopathy and classification of malignant lymphoma (ML).
Methods:
Patient characteristics, number of needle passes, puncture route, sensitivity, specificity, and accuracy of cytology/histology for lymphadenopathy were analyzed in patients diagnosed with lymphadenopathy by EUS-FNA using conventional or Franseen needles.
Results:
Between 2012 and 2022, 146 patients met the inclusion criteria (conventional [n=70] and Franseen [n=76]). The median number of needle passes was significantly lower in the conventional group than in the Franseen group (3 [1–6] vs. 4 [1–6], p=0.023). There were no significant differences in cytological/histological diagnoses between the two groups. For ML, the immunohistochemical evaluation rate, sensitivity of flow cytometry, and cytogenetic assessment were not significantly different in either group. Bleeding as adverse events (AEs) were observed in three patients in the Franseen group.
Conclusions
Both the 19-gauge conventional and Franseen needles showed high accuracy in lymphadenopathy and ML classification. Considering sufficient tissue collection and the avoidance of AEs, the use of 19-gauge conventional needles seems to be a good option for the diagnosis of lymphadenopathy.