1.Study on differentiation of murine embryonic stem cells into hepatocyte-functional cells induced by hepatocyte growth factor (HGF)
Yuru FU ; Yue CHEN ; Tianling FANG
Medical Journal of Chinese People's Liberation Army 2001;0(10):-
Objective To investigate the functional role of mur in e hepatocyte growth factor (HGF) in inducing in vitro the mouse embryonic st em cells (ESC) to differentiate unidirectionally into hepatocyte. Method s Both spontaneous and HGF induced differentiations of the primordial c ell elusters formed by suspended culture in vitro of ESC were daily observed with microscope for 5-7 days. After 4 weeks of culture, the cells were stained with HE and glycogen staining, their morphology were observed, The synthesis of urea nitrogen and triglycerides in the culture medium, the expression of myocard ial MHC, albumin, AFP and CK18, and the indocyanine green (ICG) staining were a lso detected. Results It was hard to control the spontaneous di fferentiation of ESC. HGF could promote the differentiation of ESC into endoderm , and more likely into myocardium. HGF could also induce the expression o f albumin, AFP and CK18, and positive staining of ICG and FDA. Conclusio ns HGF may induce the differentiation of ESC into hepatocyte, but the f unctional role is limited. It implies that a comprehensive effort of multiple fa ctors might be needed in inducing the hepatocyte differentiation.
2.Effect of Storing Time of Venous Blood Samples on the Differential Counts of White Blood Cells by Sysmex XE-2100 Hematology Analyzer
Weizhen FANG ; Mei CHEN ; Yuru FU ; Changzhen XU
Journal of Tropical Medicine 2005;5(6):786-789,799
Objective To evaluate the influence of the storing time of venous blood samples on the differential count of WBC by Sysmex XE-2100 hematology analyzer. Methods At room temperature, the precision of the differential count of WBC by Sysmex XE-2100 hematology analyzer were tested. 38 samples were taken the differential count of WBC by Sysmex XE-2100 hematology analyzer after stored for 0, 2, 4, 8, 24 and 48 h. Differential count of WBC was also taken under microscope for comparison. Results The precision of differential count of WBC by Sysmex XE-2100for all the samples was in the allowable range. The correlation coefficient of the differential count of WBC by two methods for neutrophils, lymphocytes, monocytes, eosinophils and basophils were 0.9859, 0.9775, 0.8053, 0.8695and 0.5243 (P<0.01). There was insignificant difference in the test at 8h, very significant difference of MONO and EOS at 48 h. Differences of EOS, MONO between two methods were significant increased at 8 h. Conclusion At room temperature, the differential count of WBC of venous blood samples by Sysmex XE-2100 hematology analyzer should finish within 8 h.
3.Evaluation on the Identification and Counting of Nucleated Red Blood Cells by Sysmex XE-2100 Hematology Analyzer
Mei CHEN ; Weizhen FANG ; Yuru FU ; Qiongzhu LIN ; Changzhen XU
Journal of Tropical Medicine 2005;5(1):45-48,25
Objective To evaluate the identification and counting effeciency of nucleated red blood cells by Sysmex XE-2100 Hematology Analyzer. Methods Accurancy: nucleated red blood cells were counted from 38 specimens by Sysmex XE-2100 Hematology Analyzer and compared with the number counted under microscopy. Precision: 3 specimens with different values were counted for the nucleated red blood cells 10 times by Sysmex XE-2100 Hematology Analyzer and compared with the number counted under microscopy. The CV(% ) value was estimated.Results There was insignificant difference between the results obtained from Sysmex XE-2100 Hematology Analyzer and those under microscopy. In the T-test, P >0.05, r=0.9893(P< 0.01).CV(% ) were 8.1% and 15.8% . It means that the Sysmex XE-2100 is more precise in analyzing the nucleated red blood cells than that under microscopy. Conclusion The nucleated red blood cells count by Sysmex XE-2100 is accurate and fast to obtain clinical data.
4.Modified Bascom cleft lift procedure for chronic pilonidal sinus
Liancheng LIU ; Yuru ZHANG ; Hongyan DUAN ; Yue SU ; Bin HUANG ; Xu HAN ; Chuncheng REN ; Min WANG ; Tuanjie ZHAO ; Zhiliang ZHANG ; Fang XIONG
Chinese Journal of General Surgery 2019;34(1):42-44
Objective To evaluate the clinical efficacy of modified Bascom cleft lift procedure in the treatment of chronic sinus.Methods Modified Bascom cleft lift procedure was performed in 53 patients admitted from Oct 2012 to Jul 2016.49 cases were male and 4 were female.The average age was (25.4± 2.3) years.Results All patients were satisfied with the operation.There were 49 cases of primary healing and 4 cases of incision complications.The average follow-up was (12.1 ±4.3) months,no recurrence was observed.Conclusion The modified Bascom cleft lift technique is effective and reliable,with less complications and a lower recurrence rate.
5.Establishment of platelet donor gene bank involving specific antigen HPA 1-6/10/15/21 by real-time fluorescent PCR
Wensheng YUAN ; Qianying CHEN ; Huiyan LIN ; Yuru FANG ; Xiaolan ZHENG ; Yongqing KUANG
Chinese Journal of Blood Transfusion 2023;36(3):204-208
【Objective】 To research the genetic polymorphism of HPA 1-6/10/15/21 in platelet donors in Zhongshan area, and establish a gene bank of platelet donors with HPA locus. 【Methods】 The HPA 1-6/10/15/21 system genotyping was performed by Real time fluorescent PCR combined with TaqMan probe technology on 192 platelet donors in Zhongshan area, and the genotype frequency and gene frequency were calculated. 【Results】 Only HPA-aa genotype was found within HPA-4/10, and no allele HPA-b had been detected. The majority of HPA-1, 2, 5, 6 and 21 genotypes were aa. HPA-3 and HPA-15 showed high heterozygosity, with genotype frequency of 0.307 3, 0.494 8 and 0.197 9 for HPA- 3aa, HPA-3ab and HPA-3bb, while 0.270 8, 0.505 2 and, 0.224 0 for HPA -15aa, HPA-15ab and HPA-15bb, respectively. 【Conclusion】 The distribution characteristics of HPA 1-6 /10/15/21 of platelet donors in Zhongshan shows regional differences compared with similar researches from other regions. The establishment of HPA gene bank is helpful to avoid alloimmunization caused by incompatible platelet transfusion.
6.Prevalence of anti- "Mia" in blood donors and patients, Zhongshan city
Qiao LI ; Ainong SUN ; Shengbao DUAN ; Yonglun WU ; Yanting LIAO ; Yuru FANG ; Zhizhao YANG
Chinese Journal of Blood Transfusion 2021;34(2):114-117
【Objective】 To understand the frequency and significance of anti-" Mia" (anti-" Mia" mixtures of antibodies) in local population in Zhongshan, and the influence of different experimental conditions on the activity of human anti-" Mia" . 【Methods】 The microplate-based agglutination assay and polybrene method were used to screen anti-" Mia" in 3 587 blood samples from voluntary blood donors and patients using O type red blood cells with positive Mia antigen, then.rechecked by tube method and microcolumn gel card method. 【Results】 The frequency of anti-" Mia" was 1.06% (38/3 587), among which 60.5% (23/38) were IgM and 39.5% (15/38) were mixture of IgM and IgG; 0.61% (13/2 135) in local blood donors and 1.72% (25/1 452) in patients(P<0.01). 65.8% (25/38) of the population carrying anti-" Mia" had a history of immunity. 57.9% (22/38) were identified to be anti-" Mur" and 42.1% (16/38) anti-" Mia" using GP.Vw erythrocyte. The appropriate incubation time for anti-" Mia" test was 10 min. 【Conclusion】 The frequency of anti-" Mia" was relatively high among blood donors and patients in Zhongshan, and most of the anti-" Mia" carriers had a history of immunity. Most anti-Mia antibodies were active in saline, and some of them were mixture of IgM and IgG. It may be helpful to include Mia positive red blood cells in the irregular antibody screening cell panel to improve the safety of blood transfusion.
7.Establishment of CD36 negative platelet donor bank in Zhongshan area
Yonglun WU ; Ainong SUN ; Fei PU ; Qiao LI ; Yuru FANG ; Qianying CHEN ; Yanting LIAO ; Hongmei WANG ; Yezhou CHEN ; Shengbao DUAN
Chinese Journal of Blood Transfusion 2022;35(5):558-561
【Objective】 To investigate the frequency of CD36 deletion and gene mutation in voluntary blood donors of Zhongshan city, and to explore the possibility of establishing local CD36 negative platelet donor bank. 【Methods】 Platelet CD36 antigen was detected by ELISA in 1 654 voluntary blood donors.Some of the negative samples were confirmed by flow cytometry, and genotyping was also performed. 【Results】 Platelet CD36 antigen was negative in 27 cases, accounting for 1.6% (27/1654), among which 1.6% (18/1149) were males and 1.8% (9/505) were females.No significant difference was noticed between males and females in CD36 antigen deletion cases (P>0.05). Fifteen CD36 negative samples were randomly selected, genotyped and sequenced, with type I deletion in 1 case[ 6.7% (1/15)], type Ⅱ deletion in 14 cases[ 93.3% (14/15)], and gene mutation in exon 3-14 detected in 8 cases. 【Conclusion】 The frequency of platelet CD36 antigen deletion in Zhongshan is comparable to that in other southern regions of China.The establishment of CD36 negative platelet donor bank is conductive to improve the effectiveness of platelet transfusion.
8.Distribution of platelet antibodies and their specificity in Zhongshan area
Huiyan LIN ; Yonglun WU ; Ainong SUN ; Yuru FANG ; Qianying CHEN ; Qiao LI ; Yujue WANG ; Hongmei WANG ; Zhizhao YANG ; Xiaoyi JIAN ; Xianguo XU ; Shengbao DUAN
Chinese Journal of Blood Transfusion 2024;37(1):63-67
【Objective】 To investigate the frequency of platelet antibodies in voluntary blood donors and patients in Zhongshan, Guangdong Province, and to study the specificity and cross-matching of platelet antibodies. 【Methods】 Platelet antibodies of blood donors and patients were screened by solid-phase immunoadsorption (SPIA), rechecked by flow cytometry (FCM), and antibody specificity was identified by PakPlus enzyme immunoassay, and platelet cross-matching was simulated by SPIA. 【Results】 A total of 1 049 blood donor samples and 598 patient samples were tested, with 6 (0.57%) and 49 (8.19%) samples positive for SPIA,respectively(P<0.05); In SPIA positive samples, the positive concordance rate of FCM in blood donors and patients was 100% vs 95%, and that of enzyme immunoassay was 100% vs 88%. Among the initial screening positive samples of blood donors, 5 were anti-HLA Ⅰ antibodies, accounting for 83%, and 1 was anti CD36 antibody, accounting for 17%, with an incidence rate of 0.10%. Among the 14 samples of enzyme immunoassay positive patients, 2 were anti-GP Ⅱb/Ⅲa, 1 was anti-GP Ⅱa/Ⅱa, 8 were anti HLA Ⅰ, and 3 were mixed antibodies (HLA Ⅰ, GP Ⅱb/Ⅲa, GP Ⅰa/Ⅱa). According to the types of antibodies, HLA Ⅰ antibodies were the most common, accounting for 65% (11/17), followed by HPA related anti GP, accounting for 35% (6/17). The majority of patients had a platelet antibody positive typing rate below 30%, accounting for 71.4% (10/14). 【Conclusions】 The positive rate of platelet antibody of patients in Zhongshan area is significantly higher than that of voluntary blood donors, and most of them are anti-HLA Ⅰ and anti-GP, and the incidence of anti-CD36 is extremely low. Therefore, it is necessary to establish a known platelet antigen donor bank, and at the same time, carry out platelet antibody testing and matching of patients, which is helpful to solve the issue of platelet transfusion refractoriness.