1.Design and application of automatic exposure control circuit for filming
Xianyun WANG ; Shimin LIU ; Yunxi CAO
Chinese Journal of Radiology 2000;0(12):-
Objective To design an automatic exposure control circuit for X ray equipment to improve the performance of equipment and the quality of film. Methods The device acted in series control. During exposuring process,the X ray reaching the film through patient body was measured by ray sensor. After it was treated with integration, amplification and contrast management,the signal of X ray quantity drived the device to cut off exposure circuit, so that the exposure time was automatic any controlled. Results The effect of the device has been proved by its application in several hospitals. Conclusion The device is simple and effective and has practical value.
2.Testing and analysing the characteristics of new double three-field iono-chamber
Shimin LIU ; Yunxi CAO ; Pengcheng WANG
Chinese Journal of Radiology 2001;0(07):-
Objective To test and analyse the characteristics of double three field iono chamber developed by ourselves. Methods We tested the time characteristic, dose rate characteristic and X ray quality characteristic by using direct test method, and current characteristic, voltage characteristic and thickness characteristic of double three field iono chamber by using photograph test method with NERO 6000B test meter, RF 500 mA X ray equipment and so on. The results were analysed. Results The time characteristic and dose rate characteristic had satisfied linear scales(the return coefficients of linety scales were R =0.999 61 and R = 0.998 88 respectively). The X ray quality characteristic was steady (the maximum output variation was ? max ≤?5%). The good characteristics of current, voltage and thickness were found(the maximum variations of film density were ?D max ≤?0.01, ?D max ≤?0.15 and ?D max ≤?0.06 respectively). The excellent repeat was showed (repeating error of exposure time and dose were ?T max ≤?0.004 s and ?X max ≤0.01?10 -5 C/kg). Conclusion The performace of the new Iono chamber is excellent and steady, so it has practical value.
3.Study on correlation between exposure dose and image quality of X-ray chest radiography
Yunxi CAO ; Xiaotao CAI ; Jindong XIE ; Xin CAO
Chinese Journal of Radiological Medicine and Protection 2014;34(3):225-227
Objective To investigate optimal radiation dose for digital radiography by researching the correlation between radiation dose and image quality of high kV chest radiography.Methods The kV of chest radiography was setted on 120 kV while mAs was changed.The chest radiography phantom and the contrast detail phantom CDRAD2.0 were exposed by DR with different mAs from 1 to 25 mAs.The entrance doses were measured for all exposures and the images were read independently by 5 observers on a higher resolution monitor of diagnosis work station.The image quality figure (IQF) was measured for each image.Comparison of the mean IQFs with different exposure doses were conducted in order to determined which was the optimal exposure condition for high kV radiography.The image quality of normal adult using different mAs,4 and 10 mAs for high KV chest radiography was compared.Results When the mAs was increased from 1 to 25 mAs,the entrance doses varied from 0.067 to 1.468 mGy.With the entrance doses increasing,the value of IQF was decreased (F =31.00,P < 0.05).The values of IQF were statistically different between 1 and 4 mAs(F =15.3,P <0.05),and between 10 and 25 mAs(F =9.74,P <0.05).At 4 and 10 mAs with the entrance dose 0.250 and 0.606 mGy,the synthesis score of chest high kV radiography from two kinds of exposure dose was (24.8 ± 1.64),(25.8 ± 2.05),with no statistically significant difference.Conclusions For digital radiography,increasing radiation dose can improve image information.The optimal entrance dose of high kV chest radiography for standard body was about 0.250 mGy.
4.Design and manufacture of digital stopwatch for experiment
Yunxi CAO ; Yue XU ; Huiqin LIU ; Lemin HE
Chinese Medical Equipment Journal 1993;0(06):-
This paper introduces the digital stopwatch designed by our lab for teaching and experiment of medical imaging specialty.Its design idea,principle and configuration are discussed in detail.
5.Comparative analysis of partial imaging performance parameters of home and imported X-ray machines
Yunxi CAO ; Xianyun WANG ; Huiqin LIU ; Yongxin GUO
Chinese Journal of Radiology 2001;0(02):-
Objective To compare and analyze the performance indexes and the imaging quality of the home and imported X-ray machines through testing their partial imaging performance parameters. Methods By separate sampling from 10 home and 10 imported X-ray machines, the parameters including tube current, time of exposure, machine total exposure, and repeatability were tested, and the imaging performance was evaluated according to the national standard. Results All the performance indexes met the standard of GB4505-84. The first sampling tests showed the maximum changing coefficient of imaging performance repeatability of the home X-ray machines was ?max1=0.025,while that of the imported X-ray machine was ?max1=0.016. In the second sampling tests, the maximum changing coefficients of the two were ?max2=0.048 and ?max2=0.022, respectively. Conclusion The 2 years′ follow-up tests indicate that there is no significant difference between the above-mentioned parameters of the elaborately adjusted home X-ray machines and imported ones, but the home X-ray machines are no better than the imported X-ray machines in stability and consistency.
6.The study of tube voltage selection influencing image quality in digital chest radiography
Yunxi CAO ; Huiqin LIU ; Jianfeng QIU ; Lemin HE ; Xiaotao CAI ; Haifeng HOU
Chinese Journal of Radiology 2009;43(7):697-699
Objective To study the relationship between the selection of tube tension in digitalchest radiograph and image quality.Methods When tube current was fixed at 4 mAs, the choice of X-ray tube voltage changed from 60 to 120 kV.CDRAD2.0 contrast details phantom and normal human chest were exposed by X-ray system with 7 kinds of tube voltage (the difference between tube voltage was 10 kV) ,and the X-ray incidental dose of phantom surface was measured.Five radiologists with 3 years working experience evaluated the image quality on monitor and calculated the image quality factor (IQF) and image reading score.Statistics analysis was then performed by using ANOVA test and t test.According to the results, the optimum tube voltage range was determined.Results (1) The incidental dose of phantom surface increased with the higher tube voltage.(2)When the tube voltage was changed from 60 kV to 120 kV, the IQF value observed in CDRAD2.0 phantom image on monitor was 75.0±10.4,57.1±6.4,52.7±2.5,47.9±4.5, 46.0±3.8,46.0±2.8,45.2±3.5 ,there was significant statistical differences between groups(F=19.10, P<0.01).(3)The integrated score of the chest image quality in the tube voltage 90 kV and 120 kV were 12.4±0.9 and 13.0±0.7, respectively, and there was no statistical difference between two groups(t= 1.500,P>0.05).Conclusions (1)With the increase of tube tension,the display capacity of display device gradually strengthened.When the tube tension exceeded 90 kV, the increase of image quality on monitor was not evident.(2) With proper radiation dose, the value of tube tension in digital X-ray chest photograph was about 90 kV.
7.The effect of X-ray radiography exposure intensity on image quality of the monitor
Yunxi CAO ; Huiqin HU ; Jianfeng QIU ; Lemin HE ; Fengtan HAN ; Xuean JING
Chinese Journal of Radiology 2008;42(10):1056-1058
Objective To explore the relationship between image quality and different exposure intensity of digital radiography(DR).Methods Using a contrast-detail phantom Cdrad 2.0,observers evaluated images on the monitots when exposure parameters were 90 kV and mAs ranged from 0.5 to 16.0 mAs.Then calculate image quality figure(IQF),and ANOVA was used to analyze the difference of IQF under different radiation dose in 8 subjects.Results (1)When exposure parameters were 90 kV and mAs altered from 0.5 to 8.0 mAs.the IQF observed on the monitor was reduced,and the minimal value was 38.54±2.82.When mAs changing from 8.0 to 16.0 mAs.IQF observed on the monitor was increased,and the maximum was 44.33±2.35.(2)Under the different exposure condition,the difference of IQF values were statistically significant(F=60.35,P<0.01).Conclusions With the increased exposure intensity,the image quality on monitor increased.When mAs was 8.0 mAs,image quality was the optimum When mAs was more than 8.0 mAs,the image quality on monitor reduced.
8.Risk factors of healthcare-associated infection in patients with craniocere-bral operation
Honghui RONG ; Yunxi LIU ; Shengshan CAO ; Xiuying WANG ; Mingmei DU ; Jijiang SUO ; Yubin XING
Chinese Journal of Infection Control 2014;(8):463-466
Objective To investigate risk factors for healthcare-associated infection(HAI)in patients with craniocerebral operation,and provide reference for the prevention and control of HAI.Methods A total of 4 246 cases of craniocerebral surgery in a neurosurgery department from January 2010 to December 2012 were enrolled in the study,the risk fac-tors for HAI were analyzed.Results Of 4 246 cases of craniocerebral surgery,393 patients developed 446 times of post-operative HAI,HAI incidence rate was 9.26%,case infection rate was 10.50%,which were higher than inci-dence (2.02%)and case infection rate (3.02%)of HAI of all hospital during the same period,the difference was statistically significant (χ2 =811 .06,629.30,respectively,P <0.001).The major infection site was central nervous system (56.50%),followed by respiratory system (27.36%).Unconditional univariate logistic regression analysis showed that sex,age,community-acquired infection,primary disease,operative time,length of stay in intensive care unit (ICU)before infection,the number of surgery,invasive procedures and nasogastric tube,the difference was statistically significant (all P <0.05 ).Multivariate logistic regression analysis showed that sex,elderly pa-tients,congenital brain diseases,stay in ICU>7 d,antimicrobial use >7 d,central venous and urinary tract cathe-terization,invasive ventilator were risk factors for HAI in patients with craniocerebral operation.Conclusion The incidence of HAI in patients with craniocerebral operation is high,effective preventive and control measures accord-ing to risk factors should be strengthened to reduce the incidence of HAI.
9.Related factors of troublemaking among patients with mental disorders caused by amphetamine-type stimulants
Guojian YAN ; Li PU ; Fugui JIANG ; Xuanyi HU ; Jialing LEI ; Yuesheng CAO ; Shunzhen ZHOU ; Hua REN ; Jiajia CHEN ; Shu WAN ; Yunxi LUO ; Langbin ZHOU ; Xufeng SONG ; Jun YANG ; Wei JI
Sichuan Mental Health 2021;34(4):341-344
ObjectiveTo explore the related factors of troublemaking behaviors among patients with mental disorders induced by amphetamine-type stimulants (ATS), and to provide references for the formulation of relevant intervention measures for ATS-induced mental disorders. MethodsA total of 105 patients who met the diagnostic criteria of International Classification of Diseases, tenth edition (ICD-10) for ATS-induced mental disorders were included, and classified into troublemaking group and non-troublemaking group. The general demographic data and clinical data of the selected individuals were collected, and all patients were assessed using Social Support Rating Scale (SSRS). Then univariate analysis and multivariate Logistic regression model were used to screen the related factors of troublemaking behaviors. ResultsThe scores of SSRS, objective support dimension and social support utilization dimension were significantly lower in troublemaking group than those in non-troublemaking group, with statistical differences [(24.10±6.59) vs. (28.94±5.59), t=3.364, P=0.001; (5.50±1.96) vs. (8.20±2.13), t=5.183, P<0.01; (4.60±2.26) vs. (6.28±1.90), t=3.435, P=0.001]. Multivariate Logistic regression analysis showed that male (OR=6.061, P=0.014) was a risk factor, while high social support level (OR=0.873, P=0.018) was the protective factor for troublemaking behaviors among patients with ATS-induced mental disorders. ConclusionPatients with ATS-induced mental disorders of the males and with low social support level are at high risk of troublemaking behaviors.