1.Research on slotting optimization of medical devices warehouse in class A tertiary hospital
Chinese Medical Equipment Journal 2017;38(6):36-40
Objecive To explore modern management and optimization of hospital warehouse slotting with some class A tertiary hospital taken as an example.Methods EIQ_ABC classification method,multi-objective assignment model and genetic algorithm were used to analyze and simulate the data of 126 kinds of medical devices for 20 orders.Results The medical devices were divided into nine categories of Ⅰ A,Ⅰ B,Ⅰ C,Ⅱ] A,Ⅱ B,Ⅱ C,Ⅲ A,Ⅲ B and Ⅲ C.It's suggested that emphasized management and precision slotting storage were carried out for A categories of devices,dedicated storage for B categories and random storage for C categories.At the same time,the layout of the warehouse was optimized according to the importance of the goods so that the important goods were placed near the passageway.Slotting analog simulation diagram was obtained based on multi-objective assignment model of Ⅲ A category medical device.Conclusion Classified management and allocation as well as slotting optimization of medical devices contribute to improving hospital modern management in efficiency,cost and error rate.
2.Guidance Effect of Monitoring Drug Sensitivity on Treatment of Non-gonoccocal Urethritis due to Ureaplasma urealyticum
Wencheng XUE ; Liangmin WANG ; Dongya MENG ; Xiuju FANG ; Yuning CHEN
Chinese Journal of Nosocomiology 2005;0(11):-
0.05).CONCLUSIONS The rising rates of the drug-resistant Uu strains may be resulted of no-standard treatments.The treatment time will be shortened and the curative effects will be better if the treatments are based on the results of the susceptibility test.
3.Determination of ginsenoside Rg_1 and Re in Shenqi Granula by HPLC
Yan SUN ; Weitong ZHANG ; Haibin CHEN ; Yuning WANG ; Xiaobing ZHOU
Chinese Traditional and Herbal Drugs 1994;0(07):-
Objective To establish an HPLC method for the determination of ginsenosides Rg1 and Re in Shenqi Granula.Methods Chromasil C18 column(250 mm?4.6 mm)was used with acetonitrile-0.05% phosphoric acid solution(21∶79)as mobile phase.The flow rate was 1 mL/min and the detected wavelength was 203 nm.Results Ginsenosides Rg1 and Re could be baseline separated with in 30 min.The average recovery rates were 99.60% and 98.5%,corresponding RSD were 1.93% and 2.31% for ginsenoside Rg1 and Re,respectively(n=5).Conclusion This method is fast and accurate and can be used for quality control of Shenqi Granula.
4.Study on the association between vitamin D receptor gene polymorphism of ApaI and BsmI and vitamin D deficiency rickets
Li ZHOU ; Yongsheng SHI ; Chengpeng JIANG ; Weikai WANG ; Yuning LI
Journal of Chinese Physician 2011;13(12):1627-1630
ObjectiveTo study the distribution characters and linkage disequilibrium of vitamin D receptor(VDR) gene ApaI and BsmI polymorphism,and explore the genetic susceptibility of VDR and vitamin D deficiency rickets.MethodsVDR gene ApaI and BsmI polymorphisms were determined by PCRRFLP technology in 56 cases of rickets and 76 cases of normal children.The frequencies of the VDR genotype and allele were compared between the two groups.The software SHEsis was used to make linkage disequilibrium analysis.Results No significant difference was found in either the frequency distribution of VDR gene ApaI and BsmI polymorphism or allele of them between two groups; Two polymorphisms didn't show linkage disequilibrium and D' and r2 were 0.23 and 0.01,respectively.ConclusionsThe ApaI and BsmI polymorphism of VDR gene might be not associated with vitamin D deficiency rickets.Two polymorphisms didn't show linkage disequilibrium.
5.Application value of low radiation dose coronary angiography using 320-slice volume CT
Yuning PAN ; Qiuli HUANG ; Dawei REN ; Anle WU ; Xianwang YE ; Jie ZHANG ; Xiaomin CHEN ; Jian WANG
Chinese Journal of Radiological Medicine and Protection 2012;32(4):420-424,435
Objective To evaluate the image quality and radiation dose of prospective electrocardiography-triggered coronary 320-slice volume CT angiography with different kV, and the feasibility of coronary scan with < 1 mSv radiation dose.Methods Eighty consecutive patients were randomly divided into two groups equally.The tube voltage according to paradigm was 100 kV in group A and 120 kV in group B.All raw data in group A was reconstructed by the software AIDR in CT system to create a new group named as A1. Such parameters as the mean intraluminal attenuation (SI),noise (SD),signal-to-noise ratio (SNR),contrast-to-noise ratio (CNR),effective radiation dose(E) and image quality score measured in group A were compared with those in group B.The values such as SI,SD,SNR,CNR,image quality scores were compared between group A and group A1.The significance of group B and group A1 was compared in SI,SD,SNR,CNR,image quality scores as well.Results E in group A was significantly lower than that in group B[ E =(0.67 ± 0.18) mSv in group A vs.E =(3.08 ± 1.04) mSv in group B].The value of E in group A was decreased by 78% compared to group B(t =- 14.30,P<0.05 ).There was no significant difference in mean image quality scores between two groups(4.57 ± 0.57in groupA vs.4.59 ± 0.59 in group B,t=-1.17,P>0.05).The values of SI,SD,SNR,CNR in group A were (570.8 ±131.5)HU,25.1 ±6.9,24.5 ±9.1,19.8 ±6.1.And the values of SI,SD,SNR,CNR in group B were (460.6 ± 14.3) HU,15.1 ±3.6,31.7 ±7.7,29.3 ±6.8.The values of SI and SD in group A were significantly higher than those in group B(t =4.49,8.18,P <0.05). The values of SNR and CNR in group A were lower than those in group B (t =-4.24,-6.19,P<0.05).The valuesofS1,SD,SNR,CNR,image quality scores in group Al were (557.9 ±24.5) HU,21.1 ±6.0,27.7±10.0,23.4±7.8,4.60 ± 0.56.There was no difference in the SI and the image quality scores between group A and group A1 ( t =1.09,- 1.90,P > 0.05).Conclusions 320-slice volume CT with 100 kV tube voltage and prospective ECG-triggered technique can reduce the radiation dose to less than 1 mSv and obtain optimal images in diagnosis of coronary arterial diseases.
6.The study on nucleic acid testing for bacterial detection and its preliminary application on concentrated platelet
Yuning LIU ; Xun WANG ; Danna FEI ; Xuzan HAO ; Shaou FU ; Yao JIA
Chinese Journal of Blood Transfusion 2017;30(7):702-704
Objective To establish a nucleic acid testing assay for bacterial detection with meeting automatic requirement,and use it preliminarily to detect bacterial contamination in concentrated platelet.Methods Optimizing the bacterial DNA extraction methods,evaluating the sensitivity and specificity of the optimized assay with different bacterial strains,and applying the assay on bacterial detection for 100 units of concentrated platelet.Results The optimized extraction methods met the criteria of automatic testing.The sensitivity of the assay is 10,150,65,15 CFU/mL for Escheriehia coli,Stphylococcus aureus,Bacillus subtilis,and Pseudomonas aeruginas respectively.There was no non-specific amplification detected.And the assay could detect 1 contaminated bacterial from 100 units of concentrated platelet as same as BactALT bacterial culture.Conclusions Nucleic acid testing for bacterial genome 16S DNA could detect common contaminated bacterial sensitively and fast from platelet product.This assay could have the same effect when compared to bacterial culture methods when it was applied in concentrated platelet products.
7.Protective effect of melatonin on mitochondria in diabetic rats
Chenguang WU ; Li WANG ; Jing GAO ; Chunqian FANG ; Zhigang XU ; Yingzhao LIU ; Yan CHEN ; Yuning CHEN
Chinese Journal of Geriatrics 2010;29(12):1025-1028
Objective To explore the effect of melatonin on mitochondria in streptozotocin (STZ)-induced diabetic rats and its potential mechanism. Methods The diabetic rat models were induced by intraperitoneal injection of STZ, and the diabetic rats were randomly divided into two groups: diabetes mellitus group (DM group) and melatonin-treated group (DM± MT group). The normal non-diabetic rats were served as control group. Mitochondrial membrane potential and mitochondrial swelling were measured, the expression of voltage-dependent anion channel (VDAC)was assayed by immunohistochemistry in the heart, liver and kidney among the different groups after 8 weeks. Results (1)Compared with DM group, mitochondrial membrane potential in the heart,liver and kidney were significantly elevated in DM± MT group (553.6± 193.5 vs. 311.4 ± 133.7;745.7±115.8 vs. 358.9±158.7; 951.6±246.1 vs. 425.8±177.9, all P<0.05). (2)Compared with DM group, mitochondrial swelling in the heart, liver and kidney was reinforced in DM ± MT group. (3)Compared with DM group, the expressions of VDAC in the heart, liver and kidney were significantly up-regulated in DM± MT group (76.93 ± 8.263 vs. 58.59 ± 7.62, 50.69 ± 6.33 vs.40.11±6.30, 77.86±8.59 vs. 61.44± 12.86, all P<0.05). Conclusions Melatonin has protective effect on the activity of mitochondria in the heart, liver and kidney in diabetic rats possibly by up-regulating the expression of VDAC.
8.In vitro expansion of hematopoietic stem/progenitor cells from human umbilical cord blood.
Ying GAO ; Hongnv CHU ; Chunjue GUO ; Meijue SHEN ; Xiaoling LV ; Yuning HOU ; Jinfu WANG
Journal of Chinese Physician 2008;10(10):1303-1306
Objective To separate and cultivate homo umbilical cord blood (UCB) hematopoietic stem cell (HSC) in vitro, and u-tilize bone marrow desmohemoblast stem cell as trophoblastic layer combined with cytokine to amplify umbilical cord blood hematopoietic stem/progenitor cell. Methods Ficoll lymph-cell separating medium density gradient centrifugalization was used to segregate UCBHSC.Bone marrow desmohemoblast stem ceil and cytokine were added, and the sum of NC cells and CD34 + cells was counted. Results The sum of NC cells amplified 75.2±15.0 times, and the sum of CD 34 + cells amplified 18.7±12.3 times. Conclusions It has significant effect on amplification of hematopoietic stem cell with bone marrow desmohemoblast stem cell and eytokine when HSC are cultured in vitro.
9.Coronary computed tomographic angiography at low concentration of contrast media and low tube voltage in obese patients
Yuning PAN ; Aijing LI ; Xiaomin CHEN ; Dawei REN ; Jian WANG ; Zhaoqian CHEN ; Qiuli HUANG
Chinese Journal of Radiological Medicine and Protection 2016;36(1):67-73
Objective To explore the feasibility of coronary computed tomographic angiography (CCTA) for obese patients with lower tube voltage (100 kV) and lower contrast media concentration (270 mgI/ml) using iterative reconstruction.Methods A total of 48 patients with body mass index greater than 30 kg/m2 were included and randomly divided into 2 groups according to random number table method.The images of the control group were obtained using iodine 370 mgI/ml, a tube voltage of 120 kV, and traditional filtered back projection (FBP) image reconstruction.Patients in the test group were injected with isotonic low concentration contrast media (270 mgI/ml), scanned with a lower tube voltage (100 kV), and adaptive iterative noise reduction image reconstruction algorithm (AIDR-3D) was used.Two experienced physicians scored the image quality in a double-blind way.Independent sample t-test was used to compare the effective dose (E), average CT values, signal to noise ratio (SNR), contrast to noise ratio (CNR), the figure of merit (FOM), image quality scores and the total iodine intake.Side effect was also evaluated.Results The subjective scores for control group and test group were not significantly different (P > 0.05).The scores of two physicians were consistency (Kappa =0.88, P < 0.05).The average CT values, SNR and CNR for the two groups were not significantly different (P > 0.05), but the FOM of the test group was significantly higher than that of the control group (t =-9.250,-8.604,-9.158,-5.341, P < 0.05).Effective dose in the test group was (1.61 ± 0.41) mSv, lower than that of the control group (t =8.373, P < 0.01).The total iodine and iodine injection rate in the test group were both lower than in the control group (t =7.628, 8.480, P < 0.01).The incidence of contrast mediarelated discomfort in the test group was lower than control group (x2 =18.70, 6.25, P < 0.05).Conclusions For obese patients, isotonic low concentration of contrast media and low-dose CCTA could be feasible, which substantially reduce the radiation dose and iodine intake without sacrificing image quality.Trial registration Chinese clinical trial registry, ChiCTR-DPD-15007510.
10.MPS in diagnosing and treating gastrointestinal submucosal protrusive lesions
Junbo QIAN ; Huasheng LU ; Tianmin CHEN ; Yamin WANG ; Zhenming GE ; Yuning LI
Chinese Journal of Digestive Endoscopy 1996;0(06):-
Objective To evaluate the value of miniprobe sonography (MPS) in diagnosing gastrointestinal submucosal protrusive lesions and selecting the indicated manual for treatment. Methods According to the sizes, properties, and depth of SMTs in the gastrointestinal tract detected by the MPS, different methods of resection were performed. Results Of 24 cases, 11 SMTs lying in submucosa under 2cm in diameter (2 benign gastrointestinal stromal tumors, 3 lipomas, 5 cysts, 1 granular cell tumor) were attempted with EMR or argon plasma coagulation (APC) ; there were no complications of hemorrhage or perforation. Thirteen SMTs lying in muscularis propria or with size of SMTs above 2 cm in diameter (4 malignant GISTs, 6 benign GISTs, 1 lipoma, 2 aberrant pancreas) were performed by surgical resection. Preoperative diagnoses of SMTs by MPS were consentient with their histological diagnoses. Conclusion MPS may detect the size, property, and depth of SMTs in the gastrointestinal tract and is helpful in selecting indicated cases for endoscopic resection. Endoscopic therapy of SMTs lying in mucosa or submucosa under 2cm in diameter is a safe and effective procedure.