1.Cloning, expression and characterization of HSP gene from Eimeria tenella.
Yan YAN ; Hongyu HAN ; Bing HUANG ; Qiping ZHAO ; Hui DONG ; Lianlian JIANG ; Yujian LI ; Yujuan FAN ; Qian YAO
Chinese Journal of Biotechnology 2009;25(8):1121-1129
In order to study the functions of the HSPs (Heat shock proteins) of Eimeria tenella, we cloned a novel gene (which designated EtHSP) coding HSP of Eimeria tenella by RT-PCR and RACE (Rapid-amplification of cDNA ends). The full-length cDNA sequence of EtHSP was 1802 bp, containing a 1455 bp ORF (Open reading frame) (GenBank Accession No. FJ911605) encoding a deduced protein of 484 amino acids. Real-time PCR revealed that the mRNA level of EtHSP was much higher in sporozoites of E. tenella than other developmental stages (unsporulated oocysts, sporulated oocysts and merozoites). We constructed the recombinant plasmids pET28a(+)-EtHSP, then transformed it into E. coli BL21(DE3) for expression. SDS-PAGE indicated that the fusion protein was expressed in included bodies, with peak expression 6 h after induction by IPTG Western blotting revealed that the protein was specifically recognized by polyclonal antibodies against E. tenella, showing that the fusion protein was native antigen.
Animals
;
Chickens
;
Eimeria tenella
;
genetics
;
metabolism
;
Escherichia coli
;
genetics
;
metabolism
;
Heat-Shock Proteins
;
genetics
;
immunology
;
metabolism
;
Inclusion Bodies
;
metabolism
;
Male
;
Molecular Sequence Data
;
Open Reading Frames
;
genetics
;
Rabbits
;
Recombinant Fusion Proteins
;
genetics
;
immunology
;
metabolism
;
Sequence Analysis, Protein
2.Research on posterior iliac crescent fracture
Xingye DU ; Jiaye GU ; Yunqing ZHANG ; Xuefeng JIANG ; Xiaojun YIN ; Yujian HUI ; Yaozeng XU
Chinese Journal of Orthopaedic Trauma 2020;22(3):272-276
The posterior iliac crescent fracture is a typical manifestation of injury to the posterior ring in the lateral extrusion type Ⅱ of the Young-Burgess classification for pelvic fractures. In recent years, scholars have put forward new ideas about injury mechanisms, imaging features, classification, pelvic stability and surgical procedures of this type of fractures. Minimally invasive reduction and internal fixation with percutaneous screws has been used more and more widely in the treatment of posterior iliac crescent fractures. This article reviews the clinical features, classification, treatment, problems and prospects of these fractures.
3.A sourceless efficiency calibration method based on the coupling of Monte Carlo simulation and analytical calculation
Zhen WU ; Pengwen SU ; Yujian WANG ; Hui ZHANG ; Rui QIU ; Junli LI
Chinese Journal of Radiological Health 2022;31(4):392-400
Objective To establish a sourceless efficiency calibration method by coupling Monte Carlo simulation with analytical calculation. Methods Monte Carlo simulation was used to calculate the point-to-point detection efficiency of specific detectors to establish a detection efficiency grid. The detection efficiency of point source, disc, cylindrical, beaker, spherical, U-tube and Marlin cup samples was analyzed using numerical integration method after detection efficiency grid interpolation. Results The above coupling method was used for sourceless efficiency calibration. Within the energy range of 0.2–3 MeV, the relative deviation of calibration between coupling method and Monte Carlo simulation was mostly less than 10%, the maximum relative deviation was 18.06%, and the computation time was reduced by at least 86%. The above coupling method was used for sourceless efficiency calibration of an HPGe detector manufactured by ORTEC for point source detection, which was in good agreement with the experimental calibration, and the relative deviations were less than 10%. Conclusion This method can be generalized and used in the sourceless efficiency calibration of HPGe, LaBr3, and NaI detectors.