1.Discussion of the subsidy mechanism of public hospitals in Zhejiang province
Yuhang ZENG ; Hengjin DONG ; Lin GAO ; Qian YANG ; Hao ZHANG
Chinese Journal of Hospital Administration 2017;33(2):96-97,95
Analyzed in the paper is the current subsidy mechanism for public hospitals in Zhejiang province, with analysis of problems found. The authors recommended to build a mass fraction subsidy mechanism to cover up the insufficiency of government financial subsidy; to fully leverage the price compensation of medical services; to subsidize in view of the functional positioning of various medical institutions;and explore more channels for public hospitals′subsidies.
2.Evidence-based research on the selection method system for China's essential medicine list
Hao ZHANG ; Shuyan GU ; Qian YANG ; Lin GAO ; Xuemei ZHEN ; Yuhang ZENG ; Hengjin DONG
Chinese Journal of Hospital Administration 2017;33(4):293-297
Objective To find a selection method system appropriate for China's essential drug list.Methods Collection and analysis of technical paper literature on essential drug list developement,adjustment technical papers,and literature on evidence-based medicine,pharmacoeconomics evaluation,and medical insurance budget analysis from WHO and other countries.On such basis,a method system for selecting China's essential medicine list can be proposed,with its feasibility analyzed and demonstrated.Results The GRADE assessment proposed by WHO was used to evaluate the efficacy and safety of the drug;the pharmacy economics evaluation is added to assess the economic efficiency;these were aided by the pharmacoeconomics evaluation for a comprehensive evaluation of the pharmacoeconomics of the drug in question,supplementing analysis of the medical insurance,and ensuring its affordability of essential medicine so selected.The theory of this system is well developed,and supporting software ready for application.Examples in Zhejiang Province regarding essential medicine for diabetes have proved this method feasible.Data acquisition constitutes a major roadblock for scientific selection due to barriers against medical insurance data sharing.Conclusions Theoretic basis and method tools are fully available for essential medicine selection,and the selection method system as proposed in this study prove feasible to some extent.Decision makers are recommended to scientifically select the essential drugs,and to encourage data sharing,in order to make the list more scientific and pragmatic.
3.Whether tiered medical care system is effective in saving costs?Cost savings estimation of the medical care system after tiered optimization in Zhejiang Province based on system dynamics model
Hao ZHANG ; Yue LIU ; Shuyan GU ; Xuemei ZHEN ; Yuhang ZENG ; Yuxuan GU ; Hengjin DONG
Chinese Journal of Health Policy 2017;10(7):13-21
The experience of various countries proves that the hierarchical diagnosis and treatment model can lead to reasonable resources allocation and utilization, however, the waste of China''s disordered treatment model has not been estimated.Nowadays, it is very important to establish a hierarchical diagnosis and treatment system during China''s healthcare system reform.Therefore, it is necessary to estimate the benefit the reform may bring.We take Zhejiang Province as an example, and adopted the system dynamics model to build the health delivery system, to emulate the hierarchical diagnosis and treatment model and the disordered model, and to evaluate the benefit.Results showed that if first option at the primary health institutions increased 10%, it could save 0.251 billion yuan, and if increased 15%, it could save 0.39 billion yuan.If the first option at the primary health institution reached 72.35% and the treatment in county reached 90%, the outpatient in tertiary hospital could reduce by 13 million, and those in primary healthcare institutions could increase by 74 million yuan.The direct healthcare cost could reduce 3.016 billion Yuan.
4.Clinical observation of peroral endoscopic myotomy for mid-esophageal diverticulum in 7 cases
Xianhui ZENG ; Xianglei YUAN ; Liansong YE ; Yuhang ZHANG ; Bing HU
Chinese Journal of Digestive Endoscopy 2022;39(9):739-743
To investigate the effectiveness and safety of diverticular peroral endoscopic myotomy (D-POEM) for mid-esophageal diverticulum. Data of consecutive patients in the prospective database with mid-esophageal diverticulum who received D-POEM in West China Hospital, Sichuan University between April 2014 to September 2019 were collected. The modified Eckardt scoring system for mid-esophageal diverticulum was used to evaluate the severity of diverticular symptoms. The effectiveness and safety of D-POEM were evaluated in terms of clinical success, technical success, complications and recurrence. A total of 7 patients with mid-esophageal diverticulum were included. Clinical and technical success was achieved in all patients with operation time of 16-70 minutes. No serious complications (2 cases with minor complications) or recurrence occurred. The follow-up time was 2-16 months. The median modified Eckardt score decreased from 3 points before operation to 0 points after operation. It is preliminarily believed that D-POEM ensures a complete septotomy between normal esophageal lumen and esophageal diverticulum. It is a safe and effective technique for mid-esophageal diverticulum. The modified Eckardt scoring system is suitable for symptom evaluation before and after treatment of mid-esophageal diverticulum.
5.Current situation and analysis of core competence of graduated midwives in standardized training in Sichuan Province
Shaochuan CHEN ; Xin WANG ; Rong SUN ; Yuhang ZENG ; Limin WANG ; Hongyu LI
Chinese Journal of Medical Education Research 2020;19(3):348-352
Objective:To understand and analyze the current situation of core competence of graduate midwives in standardized training in Sichuan Province, so as to provide a reference for the training of midwives in Sichuan Province.Methods:A total of 102 midwives who participated in standardized training and graduated from July 2016 to June 2018 in Sichuan Province were investigated by using general information questionnaire (including 14 items of general information, occupational literacy and hospital conditions) and Midwives Core Competence Scale (including 54 items and 6 dimensions). Among 109 questionnaires distributed, 102 valid questionnaires were collected. SPSS 21.0 was used to analyze the results by single factor analysis and multiple linear regression analysis.Results:The average total score of the core competency scale in this study was (203.470±32.398). The scores of postpartum health care and prenatal health care were relatively high, while the score of public health care was relatively low. Multivariate regression analysis showed that whether the maternal and infant health certificates were obtained during the training period, and whether there was a training system for midwives alone and arrangements of department rotation were the influencing factors of the core competence of the graduate midwives ( P<0.05). Conclusion:The core competence of midwives in standardized training in Sichuan province is at the middle level. The standardized training of midwives is at the initial stage and lack of systematic management. Hence, it is urgent to build a unified and standardized training system.
6.An Accurate Isotope Dilution Liquid Chromatography-Tandem Mass Spectrometry Method for Serum C-Peptide and Its Use in Harmonization in China
Yuhang DENG ; Chao ZHANG ; Jing WANG ; Jie ZENG ; Jiangtao ZHANG ; Tianjiao ZHANG ; Haijian ZHAO ; Weiyan ZHOU ; Chuanbao ZHANG
Annals of Laboratory Medicine 2023;43(4):345-354
Background:
Serum C-peptide results from various routine methods used in China are highly variable, warranting well-performing methods to serve as an accuracy base to improve the harmonization of C-peptide measurements in China. We developed an accurate isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC–MS/MS) method for serum C-peptide measurement and explored its use in harmonization.
Methods:
After protein precipitation with ZnSO4 solution, C-peptide was extracted from serum samples by anion-exchange solid-phase extraction and quantified by ID-LC–MS/MS in positive ion mode. The precision and analytical recovery of the ID-LC–MS/MS method were assessed. Seventy-six serum samples were analyzed using the ID-LC–MS/MS method and six routine immunoassays. Ordinary linear regression (OLR) and Bland-Altman (BA) analyses were conducted to evaluate the relationship between the ID-LC–MS/MS method and routine immunoassays. Five serum pool samples assigned using the ID-LC–MS/MS method were used to recalibrate the routine assays. OLR and BA analyses were re-conducted after recalibration.
Results:
The within-run, between-run, and total precision for the ID-LC–MS/MS method at four concentrations were 1.0%–2.1%, 0.6%–1.2%, and 1.3%–2.2%, respectively. The analytical recoveries for the ID-LC–MS/MS method at three concentrations were 100.3%–100.7%, 100.4%–101.0%, and 99.6%–100.7%. The developed method and the immunoassays were strongly correlated, with all R2 >0.98. The comparability among the immunoassays was substantially improved after recalibration.
Conclusions
The performance of the ID-LC–MS/MS method was carefully validated, and this method can be used to improve the harmonization of serum C-peptide measurements in China.
7.ICP-MS establishes blood lead reference method expected to improve detection accuracy
Mengyu XU ; Weiyan ZHOU ; Yuhang DENG ; Jie ZENG ; Chuanbao ZHANG
Chinese Journal of Laboratory Medicine 2023;46(2):225-230
Lead poisoning severely threatens human health with its cumulation and durability in the body. The analysis of lead in blood is vital for screening, diagnosis, treatment, and prognostication of lead poisoning and for indirectly monitoring the level of lead in the environment. Although the detection programs are available throughout our country, the accuracy and comparability of the results cannot meet the expectation. A variety of factors can affect the accuracy of blood lead testing. To promote the application of blood lead analysis in clinical trials and reduce the bias of results, a better reference system for blood lead analysis should be established to evaluate the accuracy of traditional methods, promote the standardization of blood lead analysis and achieve accurate blood lead testing.
8.Technical specification for clinical application of critical ultrasonography
Wanhong YIN ; Xiaoting WANG ; Dawei LIU ; Yangong CHAO ; Xiangdong GUAN ; Yan KANG ; Jing YAN ; Xiaochun MA ; Yaoqing TANG ; Zhenjie HU ; Kaijiang YU ; Dechang CHEN ; Yuhang AI ; Lina ZHANG ; Hongmin ZHANG ; Jun WU ; Lixia LIU ; Ran ZHU ; Wei HE ; Qing ZHANG ; Xin DING ; Li LI ; Yi LI ; Haitao LIU ; Qinbing ZENG ; Xiang SI ; Huan CHEN ; Junwei ZHANG ; Qianghong XU ; Wenjin CHEN ; Xiukai CHEN ; Daozheng HUANG ; Shuhan CAI ; Xiuling SHANG ; Jian GUAN ; Juan DU ; Li ZHAO ; Minjia WANG ; Song CUI ; Xiaomeng WANG ; Ran ZHOU ; Xueying ZENG ; Yiping WANG ; Liwen LYU ; Weihua ZHU ; Ying ZHU ; Jun DUAN ; Jing YANG ; Hao YANG ; Chinese Critical Ultrasound Study Group ; Gritical Hemodynamic Therapy Collabration Group
Chinese Journal of Internal Medicine 2018;57(6):397-417
Critical ultrasonography(CUS) is different from the traditional diagnostic ultrasound,the examiner and interpreter of the image are critical care medicine physicians.The core content of CUS is to evaluate the pathophysiological changes of organs and systems and etiology changes.With the idea of critical care medicine as the soul,it can integrate the above information and clinical information,bedside real-time diagnosis and titration treatment,and evaluate the therapeutic effect so as to improve the outcome.CUS is a traditional technique which is applied as a new application method.The consensus of experts on critical ultrasonography in China released in 2016 put forward consensus suggestions on the concept,implementation and application of CUS.It should be further emphasized that the accurate and objective assessment and implementation of CUS requires the standardization of ultrasound image acquisition and the need to establish a CUS procedure.At the same time,the standardized training for CUS accepted by critical care medicine physicians requires the application of technical specifications,and the establishment of technical specifications is the basis for the quality control and continuous improvement of CUS.Chinese Critical Ultrasound Study Group and Critical Hemodynamic Therapy Collabration Group,based on the rich experience of clinical practice in critical care and research,combined with the essence of CUS,to learn the traditional ultrasonic essence,established the clinical application technical specifications of CUS,including in five parts:basic view and relevant indicators to obtain in CUS;basic norms for viscera organ assessment and special assessment;standardized processes and systematic inspection programs;examples of CUS applications;CUS training and the application of qualification certification.The establishment of applied technology standard is helpful for standardized training and clinical correct implementation.It is helpful for clinical evaluation and correct guidance treatment,and is also helpful for quality control and continuous improvement of CUS application.
9.Comparative analysis of air absorbed dose rate with different gamma radiation dose rate instrument
Longsheng CAO ; Xun DIN ; Yang YANG ; Lei ZENG ; Chenjian HU ; Anbiao LVU ; Yuhang LIAO
Chinese Journal of Radiological Health 2021;30(2):159-164
Objective In order to test and improve the monitoring technical level and ability of radiation environmental monitoring network in Zhejiang Province, ensure the accuracy and reliability of monitoring data and information, and obtain the cosmic ray response values of instruments and equipment in this year. Methods In September 2018,an intercomparison meeting of environmental gamma radiation air absorbed dose rate within the radiation environmental monitoring network of Zhejiang province was held in Ningbo,which was organized by Zhejiang Province Radiation Environmental Monitoring Center.A total of 33 sets of instruments from 15 member units participated in the intercomparison measurements at 5 environmental measuring points, and the comparison results were evaluated by the Z score values. Results It was found that the |Z| of all measurement results were less than or equal to 2, and the evaluation results were satisfactory and acceptable. Conclusion The measured data of scintillation counters have relatively wider dispersion,and the high pressure ionization chambers have bigger response valuetocosmic ray. The measurement results of the two kinds of instruments keep a good linearity except for the measurement points of cosmic ray response.