1.Study on serum autoantibody in patients with polycystic ovary syndrome in child-bearing period
Yueyun XIANG ; Anhua MAO ; Hao TAN
International Journal of Laboratory Medicine 2014;(20):2773-2774
Objective To investigate the association between serum non-organ-specific autoantibodies and polycystic ovary syn-drome(PCOS).Methods A total of 69 patients with PCOS in child-bearing period treated in our hospital were selected as the study group and contemporaneous 69 healthy child-bearing year women were selected as the control group.Serum level of antinuclear anti-bodies (ANA)was measured by ELISA,serum level of anti-dsDNA was measured by colloidal gold spot infiltration assay and the extractable nuclear antigen (ENA)auto-antibodies profiles were measured by Western blot.Results Serum levels of ANA and an-ti-dsDNA antibodies in the study group were significantly elevated compared with the control group with statistical difference.Con-clusion Serum autoantibody positive exists in the patients with PCOS.
2.Rapid detection of microalbuminuria with high-performance liquid chromatography.
Fang LIU ; Yueyun XIANG ; Keqian XU
Journal of Central South University(Medical Sciences) 2012;37(10):1066-1070
OBJECTIVE:
To develop a rapid detection method for microalbuminuria with size-exclusion high performance liquid chromatography.
METHODS:
With a new mobile phase, samples were injected onto an Agilent Zorbax GF-250 size exclusion chromatographic column. The method was evaluated and urine albumin of 56 diabetic patients was analyzed.
RESULTS:
The mobile phase containing 0.1% formic acid and acetonitrile, with 20 μL sample size, 1 mL/min flow rate, 205 nm detection wavelength. The retention time of albumin both in human serum and urine was 1.7 min. The linear range was 5-2000 mg/L. The lower limit of measurement was 2 mg/L. The intra-assay coefficient of variation and the inter-assay coefficient of variation were 3.98% and 4.05% (20 mg/L), 3.55% and 3.60% (200 mg/L), 4.65% and 4.74% (2000 mg/L), respectively. Recovery rates were 95.3%, 98.1%, and 97.2%. Microalbuminuria was detected in 30 samples by high performance liquid chromatography and 15 samples by immunoturbidimetry from 56 patients with diabetic mellitus.
CONCLUSION
A fast and high sensitivity method, namely size-exclusion high performance liquid chromatography, with mobile phase containing 0.1% formic acid and acetonitrile has been established to analyze microalbuminuria, which can detect more microalbuminuria than other methods and is suitable for clinical routine measurement.
Albuminuria
;
diagnosis
;
Chromatography, High Pressure Liquid
;
Diabetes Mellitus
;
urine
;
Humans