1.A RAPID METHOD FOR DETERMINATION OF TRYPTOPHAN IN FOODS AND FEEDSTUFFS WITH FLUORIMETRIC METHOD
Acta Nutrimenta Sinica 1956;0(02):-
A rapid method for directly determining tryptophan contents in foods and feedstuffs was described. l-5mg dry sample could be completely hydro-lyzed in a teflon tube containing 5N NaOH with 0.5% soluble starch under 145℃ for 4 hours in vacuum (760mmHg). The hydrolysate was then adjusted to neutral with 6N HCL in icebath and diluted by five times with 4M urea solution (pH = 11), and was measured at excitation wavelength 280nm and fluorescence wavelength 368nm. The sensitivity of the method was 5ng /10ml, and the recovery rate of 97-107% were obtained in the range of 1-5 ?g/10ml standard tryptophan. The value of a number of foods and feed-stuffs obtained were in agreement with the literatature values.
2.CT features of mesenteric lymphadenopathy in active Crohn’s disease
Wen LIU ; Wei WANG ; Longlong XIE ; Yuequn HU ; Sheng LIU
Journal of Practical Radiology 2016;32(4):610-613
Objective To investigate the CT features of mesenteric lymph nodes in patients with active Crohn’s disease.Methods The CT findings in 54 patients with active Crohn's disease proved by histology were analyzed,and the anatomic distribution,size, number,shape and enhancement ratio (ER)of the mesenteric lymph node were assessed.Results Mesenteric lymphadenopathy in 38 patients (70.4%)was found with a total number of 242,83.5%(202/242)of whom were located at the mesenteric root and 16.5%(40/242) at mesenteric edge.The size of the lymph nodes at the mesenteric root was larger than that at the mesenteric edge (8.57 mm±2.26 mm versus 5.38 mm±0.1 9 mm,the mean maximum short diameter),and 73.6% (1 78/242 )of the lymph nodes were oval in shape.The lymph nodes showed significant enhancement after contrast injection with an ER of 0.53 ±0.09.Conclusion Active CD often leads to mesenteric lymphadenopathy,which is more obvious at the mesenteric root.
3.Application of transcranial doppler ultrasonograpy on brain death in severe craniocerebral injury
Yuequn LI ; Guohong SONG ; Shangwei LIU ; Fangfang XUN ; Zhan LIU
Chinese Journal of Behavioral Medicine and Brain Science 2016;25(5):442-445
Objective To investigate and evaluate the diagnostic value of transcranial doppler ultrasound (TCD) on brain death in patients with severe craniocerebral injury.Methods Forty-two cases of severe craniocerebral injury from Affiliated Hospital of Jining Medical University were divided into brain death group and survival group,according to the clinical prognosis.TCD was conducted to examine brain blood flow numerical and changed characteristics of the spectrum.Average blood flow velocity (Vm),pulse index (PI),diastolic blood flow in reverse (reverberating flow) and small systolic peaks in early systole (wave of spikes)were documented.TCD parameters were compared between the two groups with t test.Results In the brain death group,frequency of reverberating flow was 86.67% and frequency of wave of spikes was 13.33%.In survival group,frequency of reverberating flow was 14.81% and no wave of spikes was recorded.The difference in frequencies of reverberating flow and wave of spikes between the two groups was significant(x2 =28.25,P <0.01).The average speed of bilateral middle cerebral artery blood flow in brain death group((20.02±13.96) cm/s) was significantly reduced compared with survival group((56.81± 16.84) cm/s,t=2.30,P<0.05).Pulse index (PI) values in brain death group (4.02±3.49)were significantly increased compared with survival group (1.24±1.03) (t=2.10,P<0.05).Conclusion Reverberating flow or wave of spikes is an important marker for brain death in patients with severe craniocerebral injury.TCD may be applied to clinically confirm the diagnosis of brain death.
4.The application of a high-performance bloodstain testing reagent in forensic scene
Yuequn SHI ; Weibin LIU ; Ying QIN ; Liyan ZHANG ; Zhen LI
Chinese Journal of Forensic Medicine 2017;32(2):179-181
Objective To develop a highly sensitive luminescent reagent for bloodstain testing at forensic crime scenes.Methods Based ontheprincipleof ECL luminescence and the ping-pong conjugate activation principle of chemical electronic chain,this project developed a new type of highly sensitive luminescent reagent for bloodstain testing by usingthe uniform design of experimental methods to optimize the conditions andsynthesize several new compounds.Results The bloodstain testing luminescent reagentdeveloped in this project has high sensitivity andlongluminescence time.In the case of blood samples diluted by 1,000 times,reading the fluorescence withChemiScope 3300 chemiluminescence imaging system,the maximumvalue of gray scale reached 56,and the luminescence time lasted for 10 minutes.Conclusion The project has successfully developed a highly semitivebloodstain testing reagentthat could be applied to crime scene investigation.