1.The early results of total hip replacement with a proximally hydroxyapatite-coated femoral component
Junying SUN ; Yuefeng HAO ; Peiyan YANG
Chinese Journal of Orthopaedic Trauma 2002;0(01):-
Objective To summarize the early results of total hip replacement with a proximally hydroxyapatite-coated femoral component. Methods From February 2000 to October 2003, 65 cases (70 hips) underwent uncemented total hip replacement with a proximally hydroxyapatite-coated femoral component (U2, United Orthopedic Corporation, Taiwan, China). The diagnosis included femoral neck fractures in 30 cases, osteoarthritis in 15 cases, avascular necrosis of the femoral head in 9 cases, loosening of artificial femoral head in 8 cases, rheumatoid arthritis in 2 cases, and arthrodesis in 1 case. Clinical and radiographic evaluations were performed at 1 week, 3 and 6 months postoperatively, and yearly afterwards. Bone mineral density (BMD) of the proximal femur was measured with dual-energy X-ray Absorptiometry (DEXA) for 44 cases. Results Postoperative X-ray films showed that the initial fixation was excellent or good in all the stems. The follow-ups averaged 3 years (2 to 5.5 years). The mean preoperative Harris hip score was 32 (25 to 52) points, which were improved to 96 points at the latest follow-ups. There was no reported incidence of thigh pain at any time throughout our study. And no case needed revision. By the measurements on the X-ray films taken within 1 year postoperatively, 7 of the 70 stems had subsidence of less than 1.5 mm. No hip experienced extensive proximal end osteolysis, intramedullary osteolysis, or loosening. DEXA showed that the BMD values decreased after operation, and then returned rapidly to the normal or near normal ones 3 to 6 months after operation, especially in zones Ⅱand Ⅵwhere the increase was even more significant than at the control side. All the stems were radiographically stable with evidence of osseous ingrowth typically seen in HA-coated zones, according to the criteria proposed by Engh et al. Conclusions Since HA-coating on femoral implants can enhance the initial fixation of implants, accelerate bone ingrowth and osseous fixation of the femoral component, and seal the interface between the implant and bone to prevent ingress of polyethylene particles, it is helpful in improving clinical results of the cementless total hip replacement.
2.Clinical application of double foliated anterolateral thigh flap in wound repair
Guohai LU ; Yuefeng HAO ; Lixing YU
Chinese Journal of Trauma 2010;26(4):334-336
Objective To investigate the methods and effects of the double foliated anterolateral thigh flap in wound repair.Methods From March 2001 to January 2007,nine patients with adjacent soft tissue defects were treated by double foliated anterolateral thigh flap.Of all patients,three patients were with perforating injury.Results All the transplanted flaps survived,except for one patient with superficial necrosis in extremities,who got healed with dressings change and anti-infective therapy.All patients were followed up,which showed that all flaps had excellent appearance,with a normal color and consistency.Conclusion The double foliated anterolateral thigh flap has the advantages of foliated anterolateral thigh flap and is an optimal method for repairing adjacent soft tissue defects.
3.Changes of myocardial membrane gene expression of natrium pump isoforms in rat with myocardial ischemia reperfusion injury
Yongsheng KE ; Yuefeng CHU ; Guohua YU ; Hao YANG
Chinese Journal of Clinical Pharmacology and Therapeutics 2000;0(03):-
AIM: Changes of endoxin level, ATPase activities, intramitochondrial Ca2+ concentration, and gene expression of Na+-K+-ATPase isoforms in myocardium of rats with MIR and effect of verapamil were observed, in order to investigate mechanism of endoxin mediating intracellular calcium overload of myocytes. METHODS: Twenty four male Sprauge Dawley rats were randomized into 3 groups. Sham operation group: silk suture was threaded the left anterior descending coronary artery without ligature; MIR group (MIR): left anterior descending coronary artery was subjected to 30 min ligation followed by 45 min reperfusion; verapamil group: MIR model was given 5 mg/kg verapamil. Verapamil was injected via femoral vein 5 min before reperfusion. Left ventricle myocardium samples were processed immediately after reperfusion in order to measure the activities of Na+-K+-ATPase and Ca2+-Mg2+-ATPase, endoxin level, and intramitochondrial Ca2+ concentration. The levels of ?1, ?2, ?3 and ?1 isoforms of Na+-K+-ATPase were measured by immunohistochemical assay. RESULTS: After MIR, the level of endoxin in myocardium was substantially increased; the activities of Na+-K+-ATPase and Ca2+-Mg2+-ATPase in myocardial membrane were significantly decreased while the concentration of intramitochondrial Ca2+ was increased; the levels of the ?1, ?2, ?3 and ?1 isoforms of Na+-K+-ATPase were reduced markedly. Verapamil had only effect on reducing the concentration of intramitochondrial Ca2+. CONCLUSION: MIR increases endoxin secretion. The latter may depress the activity of Na+-K+-ATPase by changing the gene expression of ?1, ?2, ?3 and ?1 isoforms of Na+-K+-ATPase in myocardial membrane, inducing intramitochondrial Ca2+ overload.
4.Endoxin antagonist up-regulates gene expression of sodium pump isoforms in rats with myocardial ischemia reperfusion injury
Yongsheng KE ; Yuefeng CHU ; Hao YANG ; Guohua YU
Chinese Journal of Pathophysiology 2000;0(12):-
AIM: To observe the effect of endoxin antagonist,anti-digoxin antiserum,on endoxin level,ATPase activities,intramitochondrial total calcium concentration and gene expression of sodium pump isoforms in myocardium of rats with myocardial ischemia reperfusion(MIR).METHODS: Fifty-six male Sprauge Dawley rats were randomly divided into 7 groups.Sham operation group: silk suture threading the left anterior descending coronary artery without ligature;MIR group: left anterior descending coronary artery was subjected to 30 min ligation followed by 45 min reperfusion;normal saline group: MIR model was given 5 mL/kg normal saline;verapamil group: MIR model was given 5 mg/kg verapamil;low dose antidigoxin antiserum group: MIR model was given 8.6 mg/kg antidigoxin antiserum;middle dose antidigoxin antiserum group: MIR model was given 17.3 mg/kg antidigoxin antiserum;high dose antidigoxin antiserum group: MIR model was given 34.5 mg/kg antidigoxin antiserum.All drugs were injected into vessel via femoral vein within 5 min before reperfusion,respectively.After reperfusion,left ventricle myocardium samples were processed immediately in order to measure the activity of Na+-K+-ATPase and Ca2+-Mg2+-ATPase,endoxin level,intramitochondrial total calcium concentration and the experssion of ?1,?2,?3 and ?1 isoforms of sodium pump on mRNA and protein levels by RT-PCR and Western blotting and immunohistochemical assay,respectively.RESULTS: After MIR,the level of endoxin in myocardium was obviously increased.The activities of Na+-K+-ATPase and Ca2+-Mg2+-ATPase in myocardial membrane were significantly decreased while intramitochondrial total calcium concentration increased.The gene expression of the ?1,?2,?3 and ?1 isoforms of sodium pump at both mRNA and protein levels were reduced markedly.Only the effect of verapamil on reducing intramitochondrial total calcium concentration was observed.Antidigoxin antiserum significantly reduced the level of endoxin in myocardium,restored the activities of Na+-K+-ATPase and Ca2+-Mg2+-ATPase,reduced intramitochondrial total calcium concentration,and up-regulated the expression of ?1,?2,?3 and ?1 isoforms of sodium pump at both mRNA and protein levels.CONCLUSION: MIR results in increase of endoxin secretion.The latter depresses the activity of Na+-K+-ATPase by down-regulating the gene expression of ?1,?2,?3 and ?1 isoforms of sodium pump in myocardial membrane,and also induces intramitochondrial calcium overload,thereby mediates MIR injury.
5.Effect of acute hypervolemic hemodilution on expression of serum chemokine interferon-inducible protein 10 in patients undergoing total hip replacement
Qifeng TANG ; Yuefeng HAO ; Yanning QIAN ; Zhongyun WANG ; Hongxing ZHANG
Clinical Medicine of China 2009;25(12):1233-1235
Objective To study the effect of acute hypervolemic hemodilution on expression of serum chemokine interferon-inducible protein 10 in patients undergoing total hip replacement.Methods Twenty ASA Ⅰ or Ⅱ patients undergoing elective total hip replacement were randomly divided into 2 groups (n=10 each):HES group and LR group.The patients in HES group received 6% HES 20 ml/kg in rate of 30 ml/(kg·h) after anesthesia.The patients in LR group received Ringer's solution 20 ml/kg in rate of 30 ml(kg·h) after anesthesia.The blood loss,blood transfusion and the time of operation were recorded.Venous blood samples were taken before anesthesia (T0),at the begining of operation (T1),30 min after operation (T2),and at the end of operation (T3),in determination of serum chemokine interferon-inducible protein 10.Results The blood loss and the blood transfusion in HES group were (560±90)ml and (200±100) ml,those were significantly lower than that in LR group[(810±110)ml and (600±200)ml].The IP-10 concentrations were significantly increased at T2~T3 as compared to baseline value at T0 in both groups,but were higher in LP group[(77.3±13.8) ng/L and (89.9±15.1) ng/L]than those in HES group [(62.8±13.6) ng/L and (65.4±10.2) ng/L,P<0.05].Conclusions Acute hypervolemic hemodilution can abate blood loss and blood transfusion during total hip replacement operation.Preoprative infusion with hydroxyethyl starch can attenuate the immunological depression during operation and anesthesia.
6.Application of MR small FOV surface coil in talar osteochondral lesions imaging
Yan SUN ; Junkang SHEN ; Yuefeng HAO ; Wei QIN ; Jixiong XU ; Dan HU ; Kefu LIU
Chinese Journal of Medical Imaging Technology 2017;33(3):454-457
Objective To compare the accuracy rate of talar osteochondral lesions between the small field of view (FOV) surface coil MR imaging and 2D FSE proton density weighted imaging (2D-FSE-PD),3D-SPACE sequences MR imaging with boot-shaped coil.Methods Totally 43 patients (45 ankles) underwent 3D-SPACE sequence after 2D-FSE-PD sequence scanning using the boot-shaped coil,then the PDWI sequence was scanning after the boot-shaped coil was replaced by the small FOV surface coil at 1.5T MRI.The results of the arthroscopic examinations was regarded as the standard for assessing the accuracy rate of the three methods.Results The accuracy rate of 2D-FSE-PD sequence with small FOV surface coil was 86.67% (39/45),the accuracy rate of 2D-FSE-PD sequence with boot coil was 60.00% (27/45),the accuracy rate of 3D-SPACE sequence with boot coil was 68.89% (31/45).The accuracy rate of small FOV surface coil was higher than those of boot coil used 3D-SPACE sequence (x2 =4.114,P =0.002) and boot coil used 2D-FSE-PD sequence (x2 =8.182,P<0.001).There was not significant difference between 3D-SPACE sequence using boot coil and 2D-FSE-PD sequence using boot coil (x2 =0.776,P=0.125).Conclusion Compared with the 2D-FSE-PD and 3D-SPACE sequences with boot-shaped coil,the small surface coil scanning with routine sequence can show talar osteochondral lesions better.
7.Comparative study of MR 3D-SPACE,3D-True FISP and 2D-FSE-PD sequences in articular cartilage of the knee joint
Yan SUN ; Xue WU ; Ping XIE ; Yuefeng HAO ; Dan HU ; Kefu LIU
Journal of Practical Radiology 2015;(1):131-135
Objective To compare the imaging quality of articular cartilage of the knee with 3D-sampling perfection with applica-tion optimized contrast using different flip angle evolutions (3D-SPACE),3D-true fast imaging with steady-state precession (3D-True FISP)and 2D-fast-spin-echo-proto-density(2D-FSE-PD)sequences.Methods 40 healthy volunteers and 20 patients of knee joints were examined with 3D-SPACE,3D-True FISP and 2D-FSE-PD sequences at 1.5T MRI.Signal-noise ratio (SNR),contrast-to-noise ratio (CNR)and lesion visualization of articular cartilage were compared.Results 3D-SPACE showed the highest SNR of cartilage and CNR of fluid/cartilage among the three sequences (P <0.05).3D-SPACE had the better capability for showing the lev-el I 、level Ⅱcartilage injury comparing with 3D-True FISP,but no significant difference between the cartilage injury at level Ⅲ and level Ⅳ.For all levels of cartilage injury,3D sequence was better than the 2D sequence.Conclusion Compared with the 3D-True FISP sequence and 2D-FSE-PD sequence,3D-SPACE sequence can show the structure of knee and knee cartilage injury better.
8.A MRI study on talar cartilage injury with small field of view coil and BLADE sequence under ankle traction
Yan SUN ; Yuefen ZOU ; Yuefeng HAO ; Kefu LIU ; Qixiang ZHUANG ; Dan HU
Chinese Journal of Radiology 2021;55(5):528-533
Objective:To evaluate the application values of small FOV surface coil and BLADE sequence in MR imaging on assessment of talar cartilage injury of ankle joint under traction.Methods:The clinical and imaging data of 53 patients with ankle cartilage injury in the Affiliated Suzhou Hospital of Nanjing Medical University from December 2018 to July 2020 were prospectively analyzed. All patients underwent the following MR sequences: sequence Ⅰ was fast spin echo proton density weighted (FSE-PD) BLADE sequence with surface coil small FOV, and sequence Ⅱ was FSE-PD-BLADE imaging of small FOV under horizontal load traction of ankle joint. Paired sample Wilcoxon rank sum test was used to compare the thickness of talus dome cartilage, cartilage space and subjective assessment score of image quality (including the outline of the upper surface of the cartilage at the injury, the thickness of the cartilage layer at the injury, the rupture of the cartilage at the injury, the relationship between cartilage and subchondral bone, subchondral bone collapse or trabecular fracture line) between sequence I and sequence Ⅱ.Results:There was significant difference in the thickness of central cartilage of talus between sequence Ⅰ and sequence Ⅱ [0.70 (0.60, 0.90) mm and 0.80 (0.70, 0.90) mm, Z=-2.900, P=0.004, respectively]. There was no significant difference in the thickness of medial and lateral talus cartilage between sequence Ⅰ and sequence Ⅱ (P>0.05). There were significant differences between sequence Ⅰ and sequence Ⅱ in the center [0.10 (0, 0.15), 0.89(0.63, 1.00) mm], medial [0.10(0, 0.31), 1.20(0.70, 1.25) mm] and lateral cartilage space [0.18(0.08, 0.23), 0.90(0.76, 0.94)mm] (all P<0.001). As for the subjective assessment score of talus cartilage injury, except for score in subchondral bone collapse or bone trabecular fracture line between sequence Ⅱ and sequence Ⅰ ( Z=-1.480, P=0.139), significant differences were found in all other scores ( P<0.05). Conclusion:MRI of the ankle under traction is safe and feasible. Under the condition of horizontal traction, small FOV surface coil combined with BLADE sequence can better display talus cartilage injury.
9.The role of low-back soft tissue after vertebroplasty and kyphoplasty for spinal osteoporotic fractures
Weibing SI ; Wei QIN ; Dan HU ; Jian JIAO ; Yuefeng HAO
Chinese Journal of Orthopaedic Trauma 2018;20(2):142-146
Objective To investigate the effect of soft tissue on the posterior lumbar spine after percutaneous vertebroplasty (PVP) and percutaneous kyphoplasty (PKP) for spinal osteoporotic fractures. Methods From January 2015 to December 2016, 52 patients with thoracolumbar osteoporotic fracture in our hospital underwent PKP or PVP. According to their fat suppression sequence (FSE) on Magnetic Resonance Imaging (MRI), they were divided into FSE positive and FSE negative groups. The FSE negative group had 38 patients, 9 males and 29 females with a mean age of 75.1 ± 6.0 years; the FSE positive group had 14 pa-tients, 4 males and 10 females with a mean age of 73.9 ± 5.8 years. The 2 groups were compared in terms of visual analogue scale (VAS) for lying on bed and standing at the 1, 3 and 7 days after surgery and painless ambulation at the 3 time points as well. Results There were no significant differences between the 2 groups in age, gender or responsible vertebrae distributions. When the patients were lying on bed, their VAS scores at the 1, 3 and 7 days after surgery were 4.1 ± 1.7, 3.0 ± 0.9 and 1.0 ± 0.8 for the FSE negative group, and 4.8 ± 1.0, 3.0 ± 0.7 and 1.3 ± 0.9 for the FSE positive group; when the patients were standing, their VAS scores at the 1, 3 and 7 days after surgery were 4.2 ± 1.1, 3.2 ± 0.7 and 1.9 ± 0.7 for the FSE negative group, and 5.4 ± 1.1, 4.0 ± 1.0 and 2.3 ± 0.5 for the FSE positive group. The VAS scores for standing at the 1 and 3 days after surgery for the FSE negative group were significantly lower than those for the FSE positive group (P <0.05). There were no significant differences between the 2 groups in the VAS scores for lying on bed at the 1, 3 or 7 days after surgery and for standing at the 7 days after surgery (P > 0.05). At the 1, 3 and 7 days after surgery, there were respectively 22, 37 and 38 patients in the FSE negative group who accomplished painless ambulation and there were respectively 3, 9 and 14 patients in the FSE positive group who accomplished painless ambulation. A significantly larger proportion of the patients in the FSE negative group accomplished painless ambulation than in the FSE positive group (P <0.05). At 7 days after surgery, all the patients in the 2 group accomplished painless ambulation. Conclusions The soft tissue of the lower back may play an important role after PKP and PVP, for fine soft tissue can reduce time for lying on bed and foster surgical efficiency. The VAS scores for standing may be more significant than those for lying on bed in prediction of ambulant time.
10.Bioactive glass:different application forms and functions by adjusting preparation process and doping elements
Hua GAO ; Hui CHE ; Dan HU ; Yuefeng HAO
Chinese Journal of Tissue Engineering Research 2024;28(29):4726-4733
BACKGROUND:Bioactive glass is a multifunctional synthetic composite material that releases active ions slowly and exhibits certain biological activities after affinity with tissues.Their versatility stems from the versatility of their preparation processes and components,allowing them to be applied in different clinical scenarios. OBJECTIVE:To review the main application forms,application fields of bioactive glass,as well as the influence of doping different elements on its function. METHODS:A literature search was conducted across WanFang Medical Database,CNKI Database,PubMed Database,and Web of Science Database,using the search terms"bioactive glass,slow-release ions,bone tissue engineering,composite scaffold,tissue regeneration and repair,biomedical engineering"in Chinese and English.The timeframe was limited from 2000 to 2023.Finally,88 articles were included for review. RESULTS AND CONCLUSION:(1)In terms of application forms,bioactive glass can be fabricated as coatings,particles,bone cements,and scaffolds according to needs.Coatings have the potential to enhance the biological activity of implants,yet they are susceptible to instability as a result of degradation.Particles offer a viable solution for the repair of irregular bone defects;however,particles produced through traditional methods often possess limited functionality.Bone cement provides the benefits of minimal invasiveness and injectability,yet its application is restricted to smaller bone defects.Scaffolds exhibit excellent mechanical properties and are commonly used for larger-sized bone defects,yet they have limited toughness.(2)In terms of applications,bioactive glass can be used in a variety of tissue regeneration and repair and disease treatment fields,including dentistry,orthopedics,soft tissue engineering,and cancer.(3)In terms of element doping,the addition of specific elements to bioactive glass not only improves its mechanical properties but also endows it with special biological functions such as bioactivity,degradability,and antibacterial properties.(4)Biologically active glass is a versatile material that can be used in different forms and functions by adjusting the preparation process and element doping to meet various clinical needs in bone tissue engineering and is widely used in the field of biomedical engineering.