1.Progress in Diagnosis and Treatment of Gastric Outlet Obstruction
Chinese Journal of Gastroenterology 2023;28(12):747-751
Gastric outlet obstruction,also known as pyloric obstruction or stenosis,refers to pyloric stenosis caused by mechanical compression or obstruction of the duodenum,distal stomach,pyloric duct,and anterior pyloric region.Patients will have the phenomenon that gastric contents cannot pass,accompanied by nausea,vomiting,abdominal pain,and loss of appetite and other related symptoms,which greatly reduces the quality of life of patients,has a wide range of individual impact,and has a high degree of harm.Scientific treatment of this disease has extremely important social significance.Based on the pathogenesis,clinical diagnosis and treatment strategies of gastric outlet obstruction,this article will make a certain summary for the diagnosis and treatment of gastric outlet obstruction for reference.
2.Progress in Diagnosis and Treatment of Gastric Outlet Obstruction
Chinese Journal of Gastroenterology 2023;28(12):761-765
Gastric outlet obstruction,also known as pyloric obstruction or stenosis,refers to pyloric stenosis caused by mechanical compression or obstruction of the duodenum,distal stomach,pyloric duct,and anterior pyloric region.Patients will have the phenomenon that gastric contents cannot pass,accompanied by nausea,vomiting,abdominal pain,and loss of appetite and other related symptoms,which greatly reduces the quality of life of patients,has a wide range of individual impact,and has a high degree of harm.Scientific treatment of this disease has extremely important social significance.Based on the pathogenesis,this article reviewed the clinical diagnosis and treatment strategies of gastric outlet obstruction,thus providing some reference for the diagnosis and treatment of gastric outlet obstruction.
3.Research progress on multiple mechanisms underlying visual hallucinations in schizophrenia patients
Yuchen JIANG ; Qiongyi HAN ; Xiaocui DU ; Guoting ZHEN ; Jindong TIAN ; Yao GAO ; Sha LIU ; Xinzhe DU
Chinese Journal of Nervous and Mental Diseases 2024;50(8):508-512
Visual hallucination(VH)is a common symptom of schizophrenia,the underlying mechanism has not been fully elucidated.It has been found that the dysfunction of dopamine(DA)system,the overactivation of α-amino-3-hydroxy-5-methyl-4-isoxazole-propionate(AMPA)receptor in glutamate system and the dysfunction of γ-aminobutyric acid(GABA)ergic neurons can induce VH in patients with schizophrenia.In addition,abnormalities in brain structural and functional networks and visual networks are also closely related to the occurrence of VH.The purpose of this paper is to review the neurochemistry and nerve injury mechanism of VH in schizophrenic patients to deeply understand the characteristics of VH,and make more accurate judgment in the early diagnosis,condition evaluation and treatment plan of schizophrenic patients.
4. The clinical feature and treatment strategy of tibial plateau fractures sustained with hyperextension varus
Zhaojie LIU ; Jinli ZHANG ; Qijie SHEN ; Zhongyu LIU ; Enqi LI ; Yuchen ZHEN ; Baocheng ZHAO ; Qing CAO ; Tao ZHANG ; Shaowen ZHU ; Junchao ZHAO
Chinese Journal of Orthopaedics 2019;39(21):1301-1310
Objective:
To explore the clinical features and treatment strategies of tibial plateau fractures sustained with hyperextension varus.
Methods:
Data of 11 patients of tibial plateau fractures with hyperextension varus treated from January 2008 to November 2017 were retrospectively analyzed. There were 7 males and 4 females with an average age of 41.2 years old (range, 25-67 years). Injuries were caused by falling down in 7 cases, traffic accident in 3 cases, and falling from height in 1 case, respectively. On the basis of Luo's three columns classification in tibial plateau, there were 9 cases of medial column fracture and 2 cases of medial combined with posterior column fracture. Six cases were concomitant with fibular head fracture and 2 cases with the injury of common peroneal nerve. Preoperative magnetic resonance imaging showed that there were anterior cruciate ligament injury in 3 cases, posterior cruciate ligament injury in 4 cases, medial meniscus injury in 5 cases, lateral meniscus injury in 3 cases, medial collateral ligament injury in 6 cases, iliotibial band injury in 2 cases and posterolateral complex injury of the knee joint in 9 cases, respectively. All tibial plateau fractures were treated firstly by open reduction and internal fixation via medial approach of the knee. The medial meniscuses and collateral ligaments were explored, in which of them there were 2 medial meniscuses with the marginal tear been sutured simultaneously. Then the knee joints which were still unstable after the examination of stable tests in 6 cases with posterolateral complex injuries were repaired surgically via lateral approach. Fibular head fractures were fixed with anchor nails or cannulated screws in 6 cases. The ruptured posterior cruciate ligaments in 2 cases were reconstructed with autologous tendon transplantation under endoscopy.
Results:
All the patients were followed up for an average period of 16.2 months (range, 12-22 months). All fractures were healed in 10-20 weeks with an average time of 16.5 weeks. The range of extension of the affected knee joint in all patients was 0° and the average flexion was 135° (range, 120°-145°) one year after surgery. The average flexion of affected knee in 4 cases which were only treated with the tibial plateau fracture without the mild ligament injuries was 137° (range, 132°-145°) and the average flexion of affected knee in 7 cases who were treated with tibial plateau fracture and severe posterolateral complex included posterior cruciate ligaments completely broken with reconstruction was 132° (range, 120°-140°). According to Rasmussen radiographic evaluation, the average score of all patients was 16.3 (range, 14 to 18) and clinical outcomes were rated with excellent in 10 cases and good in 1. The excellent and good rate was 100% (11/11). The mean of the hospital for special surgery (HSS) score was 86.7 (range, 79-96) and the functional scores were excellent in 9 cases, good in 2 cases thus the excellent and good rate was 100% (11/11). Both varus stress test 30° and dial test were positive in one case considered for the ligament laxity postoperatively who didn’t accept further treatment and the stabilization tests were negative in the other 10 cases. There were no intraoperative complications in all patients such as neurovascular injury. No incision infection, failure of the implants and fracture nonunion occurred postoperatively. Traumatic arthritis of the affected knee occurred one year after surgery in 1 case who had no obvious pain after treated with oral medicine.
Conclusion
The hyperextension varus injuries of the knee are rare clinically. The posterolateral complex should be evaluated thoroughly for this injury pattern. If it's necessary, the posterolateral structures must be repaired surgically after the tibial plateau fractures are fixed.
5. Biological mesh in the treatment of abdominal wall defect after tumor resection
Zhen CAO ; Yuchen LIU ; Yingmo SHEN ; Zhenyu ZOU ; Yiting LIU ; Jie CHEN
Chinese Journal of General Surgery 2019;34(10):879-882
Objective:
To investigate the clinical value of biological mesh in repairing abdominal wall defect after tumor resection.
Methods:
15 patients with abdominal wall defect left over by radial resection of abdominal wall tumor were treated with primary biological mesh herniorrhaphy from Sep 2015 to Sep 2017 at the Department of Hernia and Abdominal Wall Surgery of Beijing Chaoyang Hospital.
Results:
The operation was successful in all 15 patients. The operation time was 95(65-145)min. The hospital stay was 17(9-22)d. The patients were followed up for 18(17-32) months. postoperative seroma occurred in 8 cases, postoperative fever occurred in 1 case. One case died of multiple systemic metastases of advanced gastric cancer. All the other patients were followed up without complaining about local pain, foreign body sensation, intestinal obstruction, intestinal fistula.
Conclusions
Biological mesh is safe and feasible for the treatment of abdominal wall defect after tumor resection.
6. Consistency of ALK Ventana-D5F3 immunohistochemistry interpretation in lung adenocarcinoma among Chinese histopathologists
Lin LI ; Liping ZHANG ; Yuchen HAN ; Weiya WANG ; Yan JIN ; Qingxin XIA ; Yueping LIU ; Jin XIANG ; Chao LIU ; Shanshan LU ; Wei WU ; Zhen CHEN ; Juan PANG ; Yanfeng XI ; Yushuang ZHENG ; Dongmei GU ; Jun FAN ; Xiaona CHANG ; Weiwei WANG ; Liang WANG ; Zhihong ZHANG ; Xiaochu YAN ; Yi SUN ; Ji LI ; Feng HOU ; Jingyuan ZHANG ; Rongfang HUANG ; Jianping LU ; Zheng WANG ; Yongbin HU ; Hongtu YUAN ; Yujie DONG ; Lu WANG ; Zhenyu KE ; Jingshu GENG ; Lei GUO ; Jing ZHANG ; Jianming YING
Chinese Journal of Pathology 2019;48(12):921-927
Objective:
To understand the consistency of ALK Ventana-D5F3 immunohistochemistry (IHC) interpretation in Chinese lung adenocarcinoma among histopathologists from different hospitals, and to recommend solution for the problems found during the interpretation of ALK IHC in real world, with the aim of the precise selection of patients who can benefit from ALK targeted therapy.
Methods:
This was a multicenter and retrospective study. A total of 109 lung adenocarcinoma cases with ALK Ventana-D5F3 IHC staining were collected from 31 lung cancer centers in RATICAL research group from January to June in 2018. All cases were scanned into digital imaging with Ventana iSCANcoreo Digital Slide Scanning System and scored by 31 histopathologists from different centers according to ALK binary (positive or negative) interpretation based on its manufacturer′s protocol. The cases with high inconsistency rate were further analyzed using FISH/RT-PCR/NGS.
Results:
There were 49 ALK positive cases and 60 ALK negative cases, confirmed by re-evaluation by the specialist panel. Two cases (No. 2302 and No.2701) scored as positive by local hospitals were rescored as negative, and were confirmed to be negative by RT-PCR/FISH/NGS. The false interpretation rate of these two cases was 58.1% (18/31) and 48.4% (15/31), respectively. Six out of 31 (19.4%) pathologists got 100% accuracy. The minimum consistency between every two pathologists was 75.8%.At least one pathologist gave negative judgement (false negative) or positive judgement (false positive) in the 49 positive or 60 negative cases, accounted for 26.5% (13/49), 41.7% (25/60), respectively, with at least one uncertainty interpretation accounted for 31.2% (34/109).
Conclusion
There are certain heterogeneities and misclassifications in the real world interpretation of ALK-D5F3 IHC test, which need to be guided by the oncoming expert consensus based on the real world data.