1.Breviscapine effects on the expression of proliferating cell nuclear antigen and c-fos in the testis of diabetic rat models
Lingli LONG ; Shuhui ZHENG ; Yubin LI
Chinese Journal of Tissue Engineering Research 2015;(18):2917-2922
BACKGROUND:Breviscapine has been shown to impact the reproductive capacity in rats with type 2 diabetes mel itus, but few reports concerned its mechanism of action.
OBJECTIVE:To study the effects of breviscapine on proliferating cel nuclear antigen and proto-oncogene c-fos expression in testis of type 2 diabetes mel itus rats.
METHODS:Total y 36 healthy male rats were randomly divided into control group, model group and breviscapine group with 12 rats in each group. In the model group and breviscapine group, rat models of type 2 diabetes mel itus were established by continuous intraperitoneal injection of streptozotocin. Blood glucose reaching 16.7 mmol/L in rats was considered as the standard of model induction. In the control group, rats were given an equal volume of citrate buffer solution by single intraperitoneal injection. In the breviscapine group, rats were administered breviscapine 10 mg/(kg?d) for 4 consecutive weeks by intraperitoneal injection. Rats in the other two groups were injected with an equal volume of physiological saline at the same time point.
RESULTS AND CONCLUSION:After 4 weeks of intervention, serum testosterone testing, immunohistochemistry and PCR results showed that serum testosterone levels, proliferating cel nuclear antigen, c-Fos protein and mRNA expression:control group>breviscapine group>model group (P<0.05);blood glucose concentration:the control group
2.Comparison of two common insemination methods on in-vitro fertilization and embryo transfer
Canqiao LUO ; Yubin LI ; Tao LI ; Shan XIAO ; Lingli LONG ; Wenlin XIE ; Zhaoming NIE
Chinese Journal of Tissue Engineering Research 2014;(27):4406-4411
The in-vitro fertilization and embryo transfer technique has been widely applied in human insemination. The rate of successful insemination is gradual y rising, and the in-vitro fertilization directly determine the insemination outcome.
OBJECTIVE:To evaluate the difference between the two common using insemination methods, microdrop and open, in in-vitro fertilization and embryo development.
METHODS:A randomized study was conducted to compare microdrop and open insemination methods among non-male factor patients undergoing in-vitro fertilization and embryo transfer. A total of 1 175 cases were enrol ed in the research. There were 573 cases in the microdrop group, and 602 cases in open insemination group. The fertilization rate and embryo development in the two groups were compared.
RESULTS AND CONCLUSION:The fertilization failure rate [total fertilization failure rate+low fertilization rate (<25%oocytes fertilized)] in the microdrop insemination group was higher than in the open insemination group (11.9%, 3.3%, P<0.001), while the good quality embryo rate and pregnancy rate did not differ significantly between the two groups (al P>0.05). The open insemination method is a simple insemination method with a lower fertilization failure rate. As the fertilization is a highly complicated process involving many extrinsic and intrinsic factors, further study is needed to confirm the effects of the two insemination methods on in-vitro fertilization outcome.
3.Progress in treatment of obsolete pelvic fracture
Yubin LONG ; Zhiyong HOU ; Yingze ZHANG ; Wei CHEN
Chinese Journal of Orthopaedic Trauma 2019;21(3):241-246
Severe pelvic fractures are often accompanied with injuries to abdominal and pelvic organs and nerves and vessels as well.Timely operations for pelvic fractures may be delayed due to urgent management of serious and life-threatening injuries,rendering the fractures obsolete.Patients with severe obsolete pelvic fracture often sustain severe pain,unstable pelvis,neurovascular injuries and organ dysfunction associated with pelvic malunion and malalignment which can only be treated by surgery.This paper reviews the literature and summarizes clinical manifestations of the fracture,indications for surgery,surgical treatment algorithms and difficulties encountered during operation,with an aim to provide useful information for management of obsolete pelvic fractures.
4.Comparison of a bidirectional-traction reduction device versus a traction table in treatment of femoral neck fractures with femoral neck system
Yubin LONG ; Jingqiao LI ; Hu LIU ; Ruili JIA ; Yongwang LI ; Ming AN
Chinese Journal of Orthopaedic Trauma 2022;24(5):385-391
Objective:To compare the clinical efficacy between a bidirectional-traction reduction device and a traction table in the treatment of femoral neck fracture with femoral neck system (FNS).Methods:A retrospective study was conducted in the 46 patients with femoral neck fracture who had been treated at Department of Orthopedics, The First Central Hospital of Baoding from January 2020 to January 2021. There were 19 males and 27 females, aged from 30 to 64 years (average, 47.1 years). According to the Garden classification, 29 cases were type Ⅲ and 17 type Ⅳ. By the reduction method, the patients were assigned into an observation group ( n=24) in which the reduction was assisted by a bidirectional-traction reduction device and a control group ( n=22) in which the reduction was assisted by a traction table. FNS fixation was conducted in both groups. The 2 groups were compared in terms of operation time, reduction time, fluoroscopy frequency, intraoperative blood loss, femoral neck shortening at immediate postoperation and 12 months postoperation, Harris scores of the affected hip at 3, 6, and 12 months postoperation, and incidence of lower extremity venous thrombosis. Results:There were no significant differences in age, gender or fracture type between the 2 groups, showing they were comparable ( P>0.05). The observation group needed significantly less operation time [57.5 (54.0, 64.5) min], reduction time [(16.3±3.0) min] and fluoroscopy frequency [(20.5±4.6) times] than the control group did [85.0 (71.3, 92.0) min, (21.0±6.0) min and (29.7±4.7) times, respectively] (all P<0.05). There was no significant difference in intraoperative blood loss between 2 groups ( P>0.05). All patients were followed up for 12 to 22 months (average, 15.5 months). There was no significant difference in femoral neck shortening between the 2 groups at immediate postoperation or 12 months postoperation ( P>0.05). The Harris score of the affected hip in the observation group was significantly better than that in the control group at 3 months after surgery ( P<0.05), but such a significant difference was not observed at 6 or 12 months postoperation ( P>0.05). The incidence of thrombotic complications in the observation group (12.5%, 3/24) was significantly lower than that in the control group (40.9%, 9/22) ( P<0.05). Conclusions:In the FNS treatment of femoral neck fracture, compared with a traction table, reduction assisted by a bidirectional-traction reduction device is more advantageous because it is simpler and less time-consuming, incurs less fluoroscopy and leads to better early functional recovery of the affected hip and lower incidence of thrombotic complications.
5.Biomechanical comparison of Ortho-Bridge system and plate fixation system for femoral periprosthetic type Vancouver B1 fracture
Wen WANG ; Yuntao LONG ; Guilai ZUO ; Yubin QI ; Jianke LIU
Chinese Journal of Orthopaedics 2022;42(1):47-53
Objective:To compare the biomechanical parameters of Ortho-Bridge system (OBS) and locking compression plate+locking attachment plate (LCP+LAP) in the fixation of femoral periprosthetic type B1 fracture.Methods:The same periprosthetic type B1 fracture of human femur were made, including simple fracture model and comminuted fracture model, 12 in each. And the simple fracture models were randomly divided into 6 pieces of OBS system fixation group and 6 pieces of LCP+LAP system fixation group, and the complex fracture models were also randomly divided into 6 pieces of OBS system fixation group and 6 pieces of LCP + LAP system fixation group. Then the four groups of models were tested by axial compression and torsion tests, and the stiffness of the models under axial compression and torsion angle of the models under torsion test were collected. The axial compression failure test was carried out to collect the vertical load of the ultimate failure test. The axial stiffness, torsion angle and axial failure load of OBS and LCP+LAP fixed simple and comminuted fractures were statistically analyzed by t test. Results:For the test of fixed simple fracture, there was no significant difference ( t=0.535, P=0.522) in the axial stiffness between the OBS group (868.87±157.14 N) and the LCP+LAP group (904.53±44.76 N), whereas the results of torsion test showed that the LCP+LAP group had a higher torsion angle 7.17°±0.52° than the OBS group 5.45°±0.44° ( t=5.616, P<0.001); When fixing comminuted fractures, the OBS group had a higher axial stiffness (145.33±10.34 N) than the LCP+LAP group (84.15±8.94 N) ( t=10.961, P<0.001), but the LCP+LAP group had a higher torsion angle 7.75°±1.17° than the OBS group 5.23°±0.31° ( t=4.652, P=0.001). Ultimate failure test data showed that the failure pressure of OBS fixed group (4 967.49±132.88 N) was higher than LCP+LAP group (3 967.41±145.16 N) ( t=12.447, P<0.001). In the LCP+LAP group, there was destruction of the contact cortex at the fracture site, while in the OBS group, there was destruction of the contact cortex at the fracture site as well as fractures around the proximal fixation screw. Conclusion:OBS group has similar axial compression resistance to LCP+LAP group, but better torsion resistance than LCP+LAP group when it is used to fix B1 simple fracture around femoral prosthesis. When comminuted fracture is fixed, the axial compression resistance and torsion resistance of OBS group are better than LCP+LAP group. The stress is dispersed during OBS fixation, which can better avoid the failure of internal fixation during early functional exercise.
6.Study on the intenal fixation of distal femoral fracture with Ortho-Bridge system in elderly patients
Yubin QI ; Jianke LIU ; Hongmei SUN ; Yuntao LONG ; Guilai ZUO ; Wen WANG
Chinese Journal of Orthopaedics 2022;42(14):897-904
Objective:To introduce the surgical method of Ortho-Bridge system (OBS) in the treatment of distal femoral fractures in elderly patients and investigate its clinical effect.Methods:From January 2018 to July 2021, 24 elderly patients who suffered distal femoral fractures were treated with bilateral OBS. There were 8 males and 16 females aging from 62 to 87 years, with an average age of 72.6 years. It included 15 cases of simple distal femoral fractures. According to AO classification, there were one case of A1, two of A2, five of A3, two of C1, three of C2 and two of C3. Nine cases of femoral periprosthetic fractures after total knee arthroplasty (TKA) were classified as type II according to rorabeck's classification. After operation, all patients were guided to perform knee joint functional exercise and to measure the range of motion of the knee joint. Then imaging examinations were used to evaluate the fracture healing and measure the femoral-tibial and femoral angles. The American Hospital for Special Surgery (HSS) knee joint scoring system was used to evaluate the knee function.Results:All 24 patients successfully completed the operation. The operation time was 84-115 min, with an average of 96.6 min; the intraoperative blood loss was 150-335 ml, with an average of 240 ml. All patients were followed up for 8-17 months, with an average of 13.6 months. Except for 1 case of nonunion due to few primary bone grafts, which required secondary bone grafting, the other 23 cases achieved bone union. The healing time was 3.5-6 months, with an average of 4.6 months. At 1, 3, and 6 months after operation and at the last follow-up, the flexion angles of knee were 92.2°±10.2°, 98.6°±13.3°, 106.4°±13.7°, 115.7°±15.3°, and the extension angles were -4.7°±4.1°, -1.2°±4.2°, 0.7°±4.5°, 1.8°±4.6°, respectively; and all differences were statistically significant ( F=17.03 and 12.68, P<0.001). The knee flexion and extension angles at the last follow-up were greater than 1, 3, and 6 months after operation, and the differences were statistically significant ( P<0.001). The femoral-tibial angle was 171.2°±2.4° and 170.7°±3.2°, and the femoral angle was 80.3°±1.7° and 79.6°±2.1°, respectively, at the immediate postoperative and last follow-up, with no significant difference. The HSS scores at 1, 3, 6 months after operation and at the last follow-up were 71.5±7.5, 74.6± 9.3, 78.9±10.4 and 84.7±9.4 respectively, with significant difference ( F=9.17, P<0.001). At the last follow-up, the HSS score was higher than that at 1, 3, and 6 months after the operation, and the differences were statistically significant ( P<0.001), and the knee function was evaluated according to the HSS scoring system: excellent in 12 cases, good in 9, fair in 3, with an excellent and good rate of 88% (21/24). There was no OBS crack or fixation failure in all patients, and no prosthetic loosening and instability occurred in patients with periprosthetic femoral fractures after TKA. Statistical analysis of the data at the last follow-up between the distal femoral fracture group and the periprosthetic femoral fracture group after TKA showed that the knee flexion function and HSS score of the periprosthetic femoral fracture group after TKA (126.8°±3.7°, 92.2±4.1) were both better than the simple distal femur fracture group (108.9°±15.7°, 80.2±8.8). The difference was statistically significant ( t=4.22, 4.52, P<0.05). One patient had incision fat liquefaction and healed after debridement; bone nonunion occurred in 1 case, which healed after iliac bone grafting. Conclusion:Double OBS has a good clinical effect in the treatment of distal femoral fractures in the elderly, especially in patients with periprosthetic femoral fractures after TKA.