1.Research progresses of caudal block guided by ultrasound
Chinese Journal of Interventional Imaging and Therapy 2017;14(9):580-583
Caudal block has much advantages such as simple operation,less complications,obvious effect,flat and low anesthesia.For those reasons,caudal block is widely used in pain treatment and clinical anesthesia.The traditional way of sacral canal anesthesia is based on osseous marks.However,because of variable anatomical structure in sacral canal and the sacral horns,the traditional method has many defects.In recent years,as a new operation method,caudal block under the guidance of ultrasound has began to be applied gradually.The advantages,application progresses of this method were reviewed in this paper.
2.Experimental study on preparation and in vivo enhanced effect of a novel lipid perfluorooctylbromide nanoparticles
Yang YANG ; Zhigang WANG ; Yuanyi ZHENG ; Yefeng ZHU ; Yong ZHANG
Chinese Journal of Ultrasonography 2009;18(2):171-174
Objective To prepare a kind of new lipid perfluorooctylbromide(PFOB) nanoparticles and to explore its potential application as an ultrasound contrast agent. Methods Lipid PFOB nanoparticles were prepared by microfluidization techniques. The morphology and distribution were observed with optical microscope and transmission electron microscope. Particle size and electric potential were determined with Malvern laser light scattering analyzer. Twelve normal Wistar rats were performed directly contrast imaging after injection of PFOB nanoparticles via caudal vein. Vital signs of the rats were monitored during the whole study. And eehogenie intensity of the liver was dynamically quantified through DFY ultrasound quantified analysis system. The mechanism of enhancement was studied by the frozen sections of rat's liver and spleen. Results The nanoparticles size and distribution were highly uniformed. The grey scale ultrasound imaging of the rat's liver and spleen were enhanced by PFOB nanoparticles. Ten seconds after PFOB nanoparticles injected,enhancement of liver began, the peak time was approximately 3 - 4 min, the duration of contrast enhancement was nearly up to 1 h, The enhancement of spleen was more significant and the duration was much longer. No abnormal changes of the rat's vital signs appeared during the study. Frozen sections suggested that PFOB nanoparticles accumulated in the liver and spleen was the potential mechanism of enhancement. Conclusions This novel and safe lipid PFOB nanoparticles could make prolonged enhancement of rat's liver and spleen,which has a good potency for ultrasound application.
3.A retrospective study of ultrasonographic characteristics and clinical factors affecting the BI-RADS classification (probably benign breast lesions)
Lizhi TANG ; Zhigang WANG ; Haitao RAN ; Yuanyi ZHENG
Chinese Journal of Ultrasonography 2011;20(3):230-233
Objective To investigate how many probably benign lesions on ultrasound(US) fulfilled the published criteria and to evaluate how clinical and personal factors influenced the categorization of breast lesions.Methods A total of 487 lesions in 487 women with more than 12 months follow-up after the initial category 3 assessment on US were included.The initial US images were retrospectively reviewed according to previously published criteria,and evaluated several factors that could influence the characterization of breast lesions in clinical practice such as age,multiplicity,palpability,radiologist 's experience,and lesion size.Results Of 487 lesions,479 (98.36%) were benign and 8 (1.64%) were malignant.Of 487 lesions,203(41.68%) including 8 malignancies were reassessed as category 4.If strict criteria had been applied at initial US examination,the positive biopsy rate would have been only 3.94% (8/203) and 96.06% (195 of 203) biopsies would have been unnecessary.Lesions in women 40 years or older and multiple lesions were more frequently reassessed as category 4 (P = 0.008 and P = 0.006,respectively).The presence of palpability,lesion size,and the radiologist 's experience did not significantly influence the categorization of breast lesions on US.Of 487 probably benign lesions,41.68 % could be classified as category 4 lesions when strict criteria were applied in initial practice.Conclusions The multiplicity of the lesion and the patient 's age were found to have a significant influence on the classifcation of probably benign solid masses.
4.Fe3O4-loaded lipid perfluorooctylbromide nanoparticles as ultrasound contrast agents
Ao LI ; Zhigang WANG ; Guoqing ZUO ; Jinhong YU ; Yuanyi ZHENG
Chinese Journal of Ultrasonography 2011;20(7):625-627
Objective To study the feasibility of the Fe3O4-loaded lipid perfluorooctylbromide nanoparticles (Fe3O4-PFOB) for enhanced ultrasound imaging.Methods The Fe3O4-PFOB nanoparticles,incubated with RAW264.7 macrophage cells,were monitored by microscope and ultrasound.Twelve SD rats were randomized into two groups,Fe3O4-PFOB group and PFOB group.Ultrasound imaging of rats' liver was performed before and after intravenous injection of the contrast agents.The liver echogenic intensity was quantified by DFY ultrasound quantified system analysis.Results Incubation of the Fe3O4-PFOB nanoparticles with macrophages resulted in the uptake of Fe3O4-PFOB by macrophages.Macrophages loaded with Fe3O4-PFOB exhibited enhanced echogenicity in vitro.In in vivo imaging,Fe3O4-PFOB produced better and prolonged ultrasound enhancement of rats' liver compared to PFOB nanoparticles.Conclusions Fe3O4-PFOB nanoparticles could enhance ultrasound imaging and may potentially serve as a multimodal probe for ultrasound,CT and MR imaging.
5.Using ultrasound for assessing cervical Luschka's joint problems
Yamei LI ; Gongwei JIA ; Yuanyi ZHENG ; Qian YU ; Lehua YU
Chinese Journal of Physical Medicine and Rehabilitation 2014;36(2):95-99
Objective To test using musculoskeletal ultrasound (MSUS) to observe uncovertebral joints (UJs) and to explain the ultrasound images of UJs and their adjacent tissues,especially the vertebral artery (VA).Methods MSUS was used first with human skeletons and cadavers to localize the UJs and VA on the MSUS images with the aid of implanted needles.MSUS was then used with a patient clinically diagnosed with cervical spondylosis of the vertebral artery type (CSA) to detail the image of a normal UJ and its relationship with the adjacent tissues,especially the VA.Whether there was a lateral spur from the uncinate process (UP) was assessed to try to establish a method for measuring osteophytes.Results During the examination the patient was in supine,the neck was elevated 15cm with a pillow and was at 45 degrees of rotation to the contralateral side.The probe was placed at the medial border of the sternocleidomastoid muscle.When the longitudinal section of the common carotid artery was shown,the probe was slowly moved laterally until the VA first appeared,and then was moved up along the VA.Once the VA entered the transverse foramen,moving the probe slightly allowed the UJ behind the VA to be seen between two transverse processes.The UJ thus lies between two transverse processes,that is,between the lateral margins of two vertebral bodies and outside the intervertebral disc.The echo of the lateral border of the UP is on a straight line with the echo of the lateral margin of the vertebral body,with the VA in front of the line.It was noticed that the image of a UP with lateral osteophyte formation crossed the line and reached closer to the VA.The transverse diameter of the UJ was measured as the distance from a line cutting the lateral cortical margin of the cervical vertebra to the outer cortical margin of the lateral UP.Conclusion MSUS can clearly show the UJ and its adjacent tissues,especially the VA.It can be used to assess and measure UJs with lateral osteophyte formation.
6.Survey and analysis of physical disability (cerebral palsy) rehabilitation professionals in the Guangdong Disabled Persons' Federation system
Mude TANG ; Cifu LAO ; Yuanyi LIANG ; Qiyuan ZHENG
Chinese Journal of Rehabilitation Theory and Practice 2006;12(2):175-176
目的调查广东省残联系统肢残(脑瘫)康复专业人员现状,探讨康复专业人员的培训机制。方法通过发放问卷调查的方式,对全省残联系统43个肢残(脑瘫)康复机构进行问卷调查。结果43个肢残(脑瘫)康复机构中,地级市以上(含地级市)机构29个,地级市以下机构14个,从事肢残(脑瘫)康复专业人员总数343人,专业类别以临床医学、康复医学、康复治疗学为主(48.69%),学历类别多为中专以下(59.48%),职称类别多为初级(53.94%)或无职称(35.28%),培训需求以资格认证班(33.53%)和进修班(20.99%)为主。结论广东省残联系统肢残(脑瘫)康复专业人员整体学历偏低,对口专业人员比例低,应尽快制定广东省肢残(脑瘫)康复技术与管理规程,充分发挥行业协会作用,积极推行专业人才培训,提高康复技术水平。
7.Study of virtual touch tissue quantification in noninvasive assessment of esophageal varices in patients with hepatitis B cirrhosis
Xiaopin YE ; Haitao RAN ; Juan CHENG ; Dazhi ZHANG ; Yefeng ZHU ; Ping ZHANG ; Yuanyi ZHENG
Chinese Journal of Ultrasonography 2012;21(5):405-408
Objective To evaluate the performance of virtual touch tissue quantification (VTQ)technique in noninvasive assessment of esophageal varices (EV) in patients with hepatitis B cirrhosis.Methods One hundred and thirty-five patients were enrolled in this study.Liver shear wave velocity (LSWV) and spleen shear wave velocity (SSWV) were obtained by VTQ technique,and the detection of EV was performed by upper endoscopy per patient.The severity of EV was staged on a G1-G3 scale.Liver function was also tested.ResultsThe mean value of LSWV in patients with cirrhosis was (2.48±0.50)m/s,LSWV was not correlated with the stage of EV.The mean value of SSWV was (3.25 ± 0.44) m/s,a significant,direct,linear correlation ( r =0.66,P<0.001 ) was found between SSWV and the stage of EV.The cut-off value of SSWV for predicting the presence of EV was 3.16 m/s and the area under ROC curve was 0.83,with the sensitivity and specificity of 0.83 and 0.80,respectively.The cut-off value of SSWV for predicting severe EV was 3.39m/s and the area under ROC curve was 0.84,with the sensitivity and specificity of 0.83 and 0.77,respectively.ConclusionsIn cirrhotic patients infected with hepatitis B virus,SSWV measured by VTQ technique can be used as a noninvasive method for determining the presence and the severity of EV,however evidence to support a similar role for LSWV is lacking.
8.Study on Sudan Black B-loaded poly (lactide-co-glycolide) (SB-PLGA) contrast agents for tumor lymph node imaging
Chengcheng NIU ; Yuanyi ZHENG ; Zhigang WANG ; Haitao RAN ; Yang SUN ; Weixiang SONG ; Yufang YOU
Chinese Journal of Ultrasonography 2012;21(5):446-448
Objective To prepare polyclactic-co-glycolic acid(PLGA) polymer ultrasound contrast agent loading sudan black dye (SB-PLGA) and study the enhancement effect of it on rabbit lymph nodes imaging and as a sentinel lymph node (SLN) biopsy in the feasibility and value of the indicator.Methods SB-PLGA ultrasound contrast agent was made by double emulsion and freeze-drying methods.Thigh subcutaneous rabbit VX2 tumor model of eight lymph nodes were set up with the foot pad subcutaneous injection of contrast agents to get contrast-enhanced ultrasound imaging of the popliteal lymph node and the second inguinal lymph node stations.Then the blue stained lymph nodes were resected by popliteal lymph node dissection and the second station lymph nodes were also observed after 30 mins respectively,lymph nodes were examined by frozen sections HE staining in parallel.Results SB-PLGA microbubbles had a tight size distribution.Ultrasound imaging can be significantly enhanced lymph node imaging,the second station lymph node imaging was not obvious.Popliteal lymph node dissection for lymph node staining,30minutes later,frozen sections HE staining were seen within the lymph node contrast agent present in the lymphatic sinus and a large entry of macrophages.Inguinal lymph node dissection showed the second station of lymph nodes no blue staining.Conclusions SB-PLGA ultrasound contrast agent is good for sentinel lymph node imaging and biopsy indicator.Contrast agent retention and accumulation in the lymph nodes by the uptake of macrophages may be associated with the mechanisms of lymph node enhanced imaging.
9.Multi-functional ultrasound contrast agents for in vitro ultrasound/MR dual-mode imaging and high-intensity focused ultrasound synergism
Yang SUN ; Zhigang WANG ; Yuanyi ZHENG ; Yang ZHOU ; Hongxia SHEN ; Chengcheng NIU ; Yuping GONG
Chinese Journal of Ultrasonography 2012;(7):625-628
Objective To prepare the multi-functional ultrasound contrast agents,which were investigated for ultrasound(US)/MR dual-mode imaging and high-intensity focused ultrasound(HIFU)synergism in vitro.Methods Double emulsion method was used to prepare the superparamagnetic iron oxide(SPIO)-loaded PLGA microcapsules(s-PLGA),and its morphology,size,Fe3O4 loading capacity were assessed.Then,the prepared s-PLGA microcapsules with different concentrations were applied to perform ultrasound and MR imaging in vitro.In addition,the degassed bovine liver in vitro was directly injected into 200 μl s-PLGA in saline(0.5 mg Fe/ml)just before HIFU ablation,the saline(200 μl)and pure PLGA (200 μl)were employed for control.After HIFU ablation,the volume of coagulated tissue irradiated by HIFU was calculated.Results The s-PLGA microcapsules were observed with regular spherical morphology and its average size was(885.6 ± 133.2)nm.In vitro,the s-PLGA showed hyperechogenicity in US imaging and MR negatively enhanced effeet in T2WI,the volume of coagulated tissue irradiated by HIFU after local injection of s-PLGA was larger than that of saline and pure PLGA(P<0.05).Conclusions The prepared s-PLGA microcapsules are successfully acted as dual-mode biological imaging contrast agents for ultrasound and MR imaging and HIFU synergism in vitro.
10.Experiment study of Fe3O4-loaded polymer microspheres for combining with high-intensity focused ultrasound to damage breast cancer of rabbits
Yang SUN ; Yuanyi ZHENG ; Yang ZHOU ; Hongxia SHEN ; Qi WANG ; Zhigang WANG
Chinese Journal of Ultrasonography 2012;21(10):893-896
Objective To prepare the Fe3O4 loaded polymer microspheres(Fe3O4/PLGA),and to investigate the influence of Fe3O4/PLGA combined with high-intensity focused ultrasound (HIFU) on rabbits bearing breast tumor.Methods Double emulsion method were utilized to prepare the Fe3O4/PLGA.14 days after implantation of VX2 tumor in breast,32 rabbits were randomly divided into four equal groups.In group Ⅱ,Ⅲ,and Ⅳ,the rabbits received a percutaneous injection of 0.5 ml saline,PLGA,and Fe3O4/PLGA microcapsules solution into breast tumor at 3,6,9,12 dots,about 3 mm around the tumor respectively,and massaged for 1 min before receiving HIFU ablation,while HIFU group received HIFU ablation only.HIFU ablation parameters were the same:ablated-dot mode,acoustic power 150 W,exposure duration 5 s.After HIFU ablation,the volume of coagulative necrosis was calculated,HE staining,TEM and immunohistochemical examination of PCNA were performed to detect the structure changes of the targeted tissue caused by HIFU ablation.Results The volume of coagulative necrosis caused by HIFU ablation was substantially larger and the positive index of PCNA was lower in the necrotic region after the injection of Fe3O4/PLGA microcapsules compared to the group without injection agents,the group of saline and the group of pure PLGA microspheres under the same irritation(P <0.05).Pathological examination demonstrated the targeted tissue was destroyed severely,Fe3O4 nanoparticles were seen depositing in residual tumor cells under TEM.Conclusions The self-made Fe3O4/PLGA microspheres can effectively enhanced the biomedical effect of HIFU surgery on rabbits bearing VX2 breast tumor.