1.Comparative study on the effects of collagenase inhibitor in different eye drops
Yuanping SHEN ; Luo ZHANG ; Zheng HU
Recent Advances in Ophthalmology 2000;20(6):426-427
Objective To investigate, compare and filtrate the collagenase inhibitor effects among six kinds of eye drops for clinical use.Methods The collagenase inhibitor’s effects were detected by rat's collagen and collagenase with comassie brilliant blue colorimetric method.Results The inhibitting collagenase effects among six kinds of eye drops were different: the effect of cartopril was the strongest;the acetylcysteine and sodium edetate were more strong and the sodium citrate, sodium hyposulfite and tetracycline were less strong.Conclusion 0.5g*L-1cartopril eye drops has stronger efficacy to inhibit collagenase, with less side effect or stimulation,more convenient resource and preparation than other eye drops.
2. Diagnostic value of Cytomegalovirus DNA real-time quantitative-polymerase chain reaction in different body fluids for Cytomegalovirus pneumonia in immunocompetent infants
Weijian YANG ; Yi′nan ZHENG ; Haiguang SHEN ; Zhongwei YAO ; Huanhuan ZHU ; Yuanping TANG
Chinese Journal of Applied Clinical Pediatrics 2019;34(9):669-674
Objective:
To investigate the value of Cytomegalovirus(CMV) DNA real-time quantitative-polymerase chain reaction(RT-PCR) in different body fluids for diagnosing CMV pneumonia in immunocompetent infants.
Methods:
The clinical data of immunocompetent infants with CMV pneumonia who were treated in Pediatric Intensive Care Unit of Guangdong Women and Children′s Hospital from January 1st, 2016 to February 5th, 2018 were retrospectively analyzed.The clinical data included CMV DNA load of bronchoalveolar lavage fluid(BALF), urine, blood and cerebrospinal fluid(CSF); blood immunoglobulin(Ig)M CMV, alanine aminotransferase (ALT), X-ray and CT test of chest, combined infection, clinical manifestation and treatment.
Results:
Nine hundred and twenty-six infants received bronchoalveolar lavage by bronchoscope, and 34 cases were diagnosed as immunocompetent with CMV pneumonia.The infants with CMV pneumonia: the positive percentage of urine CMV DNA, blood CMV DNA, blood IgM CMV and ALT elevation were 100.0%(34/34 cases), 61.8%(21/34 cases), 52.9%(18/34 cases) and 20.6%(7/34 cases), respectively.There was no difference in positive percentage between blood CMV DNA and blood IgM CMV (
3.Influence of NIC X-FILE and DENCO Pre-Shaper nickel-titanium instruments on the shaping of simulated curved canals
Yurong SHEN ; Rentong NAI ; Ling ZHAO ; Feigang LIU ; Caoyang YIN ; Yuanping GU ; Tieyi CHEN
Chinese Journal of Tissue Engineering Research 2024;28(3):387-391
BACKGROUND:Root canal preparation is a key step in root canal therapy.In recent years,with the rapid development of new nickel-titanium instruments,the results of root canal shaping ability have been significantly improved.However,the shaping abilities of different nickel-titanium instruments are also different.At present,there are few reports about the influence of the shaping ability of R-phase heat treatment NIC X-FILE and DENCO Pre-Shaper in simulated curved canals. OBJECTIVE:To compare the shaping effect of NIC X-FILE and DENCO Pre-Shaper nickel-titanium instruments in preparation for simulated curved canals. METHODS:Fifty simulated resin-curved canals were selected and randomly divided into two groups(n=25).NIC X-FILE and DENCO Pre-Shaper nickel-titanium files were used for root canal preparation.The root canal preparation time was recorded.Images of pre-and post-root canal preparation were taken.Image processing and analysis software were used to measure the amount of resin removed from the inner and outer walls of the root canal at each observation point.Statistical software was used to compare the root canal preparation time and centering ability of two kinds of mechanical nickel-titanium files. RESULTS AND CONCLUSION:(1)The average root canal preparation time was(1.58±0.02)minutes in the DENCO Pre-Shaper group and(2.22±0.03)minutes in the NIC X-FILE group.There was a significant difference between the two groups(P<0.05).(2)The amount of resin removed from the inner walls of the root canal of the DENCO Pre-Shaper group at 4,5,7,8,9,and 10 mm from the apical foramen was higher than that of the NIC X-FILE group(P<0.05).The amount of resin removed from the outer walls of the root canal of the DENCO Pre-Shaper group at 3,5,6,7,and 8 mm from the apical foramen was lower than that of the NIC X-FILE group(P<0.05).(3)At 2,4,5,6,7,8,and 9 mm away from apical foramen,the centering ability of the NIC X-FILE group was better than that of the DENCO Pre-Shaper group(P<0.05),and the centering ability of the NIC X-FILE group was the best at 4 mm away from apical foramen.(4)The results show that DENCO Pre-Shaper has higher mechanical efficiency than NIC X-FILE nickel-titanium root canal files.However,the centering ability of DENCO Pre-Shaper is inferior to NIC X-FILE nickel-titanium root canal files.