1.Treatment Modalities and Long-Term Outcomes in Unruptured Vertebrobasilar Fusiform Aneurysms: A Nationwide Observational Cohort Study
Linggen DONG ; Dachao WEI ; Xiheng CHEN ; Mingtao LI ; Yang ZHAO ; Yong SUN ; Qingbin NIE ; Jun FENG ; Guomin XIAO ; Jinghua ZHOU ; Shengli HU ; Lifei FENG ; Lifeng QI ; Hongen LIU ; Geng GUO ; Yufang LI ; Renfu TIAN ; Jianghua YU ; Dianshi JIN ; Liang HAO ; Tian TIAN ; Shizhong ZHANG ; Yang WANG ; Liping LIU ; Ming LV
Journal of Stroke 2026;28(2):250-262
Background:
and Purpose Vertebrobasilar fusiform aneurysms (VBFAs) carry substantial morbidity and mortality, but optimal management for unruptured VBFAs remains unclear. We compared the safety and efficacy of conservative management (CM), stent-assisted coiling (SAC), and flow diverters (FDs) in patients with unruptured VBFAs, focusing on long-term prognosis.
Methods:
This study included data from a nationwide Chinese cohort of patients with vertebrobasilar dissecting aneurysms. Inverse probability of treatment weighting (IPTW) balanced confounders across groups. The primary outcome was poor prognosis (modified Rankin Scale score >2). Secondary outcomes included aneurysm rupture, ischemic stroke, compression symptoms, and VBFA-related deaths. Logistic regression estimated odds ratios (ORs) and 95% confidence intervals (CIs). Subgroup and sensitivity analyses were performed.
Results:
Among 1,115 patients with unruptured VBFAs, 838 (median age, 54 years; 655 men) were included. After IPTW, baseline characteristics were balanced. Median follow-up was 54 months. FD was associated with a lower risk of poor prognosis than CM (OR, 0.48 [95% CI, 0.30 to 0.77]; p=0.002), with no difference between CM and SAC. FD also reduced aneurysm rupture (OR, 0.20 [95% CI, 0.07 to 0.60]; p=0.004) and compression symptoms (OR, 0.30 [95% CI, 0.13 to 0.68]; p=0.004) versus CM. Time-to-event analyses further revealed significant differences in vertebral artery lesions and Type I–II VBFAs, whereas no significant differences were observed in basilar or vertebrobasilar junction lesions or in Type III–IV VBFAs.
Conclusions
Compared with CM, FD was associated with improved long-term outcomes in unruptured VBFAs, particularly in vertebral artery lesions and Type I–II VBFAs, although residual confounding cannot be excluded.
2.Differences in deltamethrin resistance and kdr gene mutation in Culex tritaeniorhynchus population in and outside the Yellow Sea wetland
Xiao-er ZHANG ; Zhi-ming WU ; Ye TIAN ; Qian CUI ; Yu-qian JI ; Huan WANG ; Shu-juan YANG ; Yi-chao ZHAO ; Yu WANG ; Hua-yu YIN ; Yu DING ; Guo-jin YAN ; Min-sen ZHAO ; Shou-gang ZHANG ; Bing-dong SONG ; Hong-na CHEN ; Jian GAO ; Wei-fang YANG ; Yu-fu ZHANG ; Hui LIU ; Hong-liang CHU
Acta Parasitologica et Medica Entomologica Sinica 2026;33(2):101-107
Objective To gain insights into the biological characteristics of different populations of Culex tritaeniorhynchus within and around the Yellow Sea wetland from the perspective of the occurrence of resistance, we investigated the levels of resistance to deltamethrin and kdr gene mutation in the wetland and its peripheral areas. Methods Specimens were collected from Cx. tritaeniorhynchus populations at two monitoring sites in the Rare Bird National Nature Reserve and Tiaozi Ni Wetland Scenic Area, and also from two populations in Yancheng City and the Liuhe District of Nanjing, and the resistance of these mosquitoes to deltamethrin was determined using the CDC biotest bottle method. For each concentration of deltamethrin assessed, a random subset of exposed specimens was selected for amplification of the kdr gene fragment, followed by Sanger sequencing to identify and analyze resistance-associated mutations. Results The LC50 levels of deltamethrin among mosquitoes from the four populations in Luhe, Yancheng, the Rare Bird National Nature Reserve and the Tiaozi Ni Wetland Scenic Area were 2.048 5, 7.798 2, 3.473 3, and 17.695 5 mg/mL, respectively, with corresponding concentrations of deltamethrin ranging from 0.005 to 5.000,0.050 to 50.000,0.050 to 25.000 and 0.050 to 50.000 mg/mL, respectively. Furthermore, the ranges of the KT50 values were 11.76-107.43, 67.05-216.30,29.77-107.43 and 28.40-329.51 min; the 1-h knockdown rates were 34.58%-99.15%, 9.52%-43.80%, 55.09%-73.01%, and 10.09%-68.07%; and the 24-h mortality rates were 12.15%-67.52%,9.52%-79.56%,13.17%-82.21%, and 11.01%-78.99%, respectively. With respect to kdr gene mutation, we assayed a total of 63,70,59, and 57 mosquitoes for the four populations, for which we detected L1014F mutation frequencies of 14.29%, 35.00%, 20.34%, and 31.58%, respectively, with a majority of these mutations being heterozygous for resistance. In addition, five adult mosquitoes were identified has having synonymous mutations at site 1011[i. e. , AAT(asparagine)mutation to AAC(asparagine)]. Conclusions Our findings revealed the clear resistance of Cx. tritaeniorhynchus to deltamethrin in the Yancheng region of the Yellow Sea wetland, and the resistance phenotype and kdr frequency of Cx. tritaeniorhynchus in the wetland environment were comparable to those of Cx. tritaeniorhynchus in the wetland environment, thereby indicating that the resistance of different populations of Cx. tritaeniorhynchus was homogeneous under the pressure of different insecticide selection within and around the wetland. However, the underlying mechanisms need to be further studied.
3.Heme oxygenase 1 promotes differentiation of neural stem cells into neurons under oxidative stress condition
Qinghe YU ; Ziming CAI ; He TIAN ; Pian LI ; Ye RUAN ; Jinzhu LIANG ; Shuhui LIN ; Wenping LIN
Chinese Journal of Tissue Engineering Research 2025;29(23):4931-4938
BACKGROUND:Studies have shown that upregulation of heme oxygenase-1 expression enhances cellular antioxidant and anti-apoptotic abilities.However,the effects of upregulating heme oxygenase-1 expression on the proliferation and differentiation of neural stem cells under oxidative stress conditions remain unclear.OBJECTIVE:To investigate the influence of heme oxygenase-1 overexpression on the survival and differentiation capacity of neural stem cells under oxidative stress conditions.METHODS:(1)Mouse primary neural stem cells were isolated and cultured from newborn Balb/c mice.Immunofluorescence was used to detect the neural stem cell marker Nestin.(2)Lentivirus was used to infect neural stem cells to induce heme oxygenase-1 overexpression.Flow cytometry was used to assess green fluorescent protein fluorescence.Western blot assay was performed to detect the expression levels of heme oxygenase-1.(3)H2O2 was added to the lentivirus-infected neural stem cell culture medium to simulate the oxidative stress microenvironment after spinal cord injury.Effects of heme oxygenase-1 overexpression on neural stem cell proliferation and apoptosis levels were analyzed using cell proliferation assay kits,cell apoptosis assay kits,and TUNEL staining kits.(4)The levels of lipid oxidation markers malondialdehyde,catalase,superoxide dismutase,and glutathione peroxidase were detected using assay kits.(5)Flow cytometry was used to measure intracellular reactive oxygen species levels,and neural stem cell differentiation into astrocytes and neurons.(6)The effect of heme oxygenase-1 overexpression on neuronal axon growth during neural stem cell differentiation was observed under optical and fluorescence microscopes.RESULTS AND CONCLUSION:(1)Mouse neural stem cells exhibited stable morphology,good growth status,and high expression of Nestin as detected by immunofluorescence.(2)Western blot analysis showed that the overexpression of heme oxygenase-1 in the overexpression group was significantly higher than that in the empty carrier control group.Flow cytometry was used to detect the expression of green fluorescent protein in the neural stem cells of the heme oxygenase-1 overexpression group and empty vector control group.(3)Overexpression of heme oxygenase-1 maintained the proliferative activity of neural stem cells and significantly reduced the number of apoptotic cells under oxidative stress conditions.(4)Overexpression of heme oxygenase-1 inhibited lipid peroxidation of neural stem cells under oxidative stress microenvironment,enhanced the expression of enzymes related to maintaining the oxidative-reductive balance,and significantly reduced intracellular reactive oxygen species levels.(5)Overexpression of heme oxygenase-1 promoted the differentiation of neural stem cells into neurons and reduced differentiation into astrocytes.(6)The heme oxygenase-1 overexpression group exhibited longer axons,and more intercellular connections.The above results indicate that overexpression of heme oxygenase-1 can alleviate oxidative damage of H2O2-induced neural stem cells,reduce neural stem cell apoptosis,promote proliferation,and facilitate differentiation of neural stem cells into neurons.
4.Efficacy and safety of a facilitated percutaneous coronary intervention with half-dose recombinant staphylokinase in ST-segment elevation myocardial infarction
Tian-yu WU ; Wen-hao ZHANG ; Peng-sheng CHEN ; Chen LI ; Tian WU ; Zhan LÜ ; Tong WANG ; Kun LIU ; Zhi-wen TAO ; Xiao-xuan GONG ; Liang YUAN ; Yong LI ; Bo CHEN ; Xin CHEN ; Zeng-guang CHEN ; Nai-quan YANG ; Yuan-yuan SANG ; Xiao-yan WANG ; Bai-hong LI ; Li ZHU ; Guo-yu WANG ; Xin ZHAO ; Chuan LU ; Jun JIANG ; Rui-na HAO ; Chun-jian LI
Chinese Journal of Interventional Cardiology 2025;33(8):431-438
Objective To investigate the clinical efficacy and safety of facilitated percutaneous coronary intervention(PCI)with half-dose recombinant staphylokinase(r-SAK)in patients with ST-segment elevation myocardial infarction(STEMI)who are expected to undergo PCI within 120 minutes.Methods From October 2021 to August 2022,a total of 200 STEMI patients in eight centers were included and randomly assigned in a 1﹕1 ratio to either r-SAK group or control group.Patients received loading doses of aspirin and ticagrelor and intravenous heparin and were randomized to receive an intravenous bolus of either 5 mg r-SAK or normal saline prior to PCI.The outcomes were set as ST-segment resolution(STR)at 60-90 minutes after PCI,the proportion and transition of pathological Q waves on the 5th day after PCI,and the proportion of high-sensitivity cardiac troponin T(hs-cTnT)peaking within 12 hours of onset.The safety outcome was major bleeding events defined as Bleeding Academic Research Consortium(BARC)≥type 3 bleeding during hospitalization.Results Compared with the control group,the r-SAK group had a higher proportion of STR≥70%within 60-90 minutes after PCI(58.3%vs.40.3%,P=0.009);a lower proportion of pathological Q waves(59.1%vs.74.1%,P=0.040);a lower rate of Q wave progression(14.8%vs.43.2%,P<0.001);a higher rate of Q wave disappearance(12.5%vs.3.7%,P=0.027);and a higher proportion of hs-cTnT peaking within 12 hours of symptom onset[31/40(77.5%)vs.17/33(51.5%),P=0.027].Regarding the safety outcome,no significant difference in BARC≥type 3 bleeding was found between the two groups during hospitalization(P>0.05).Conclusions For STEMI patients who were expected to undergo primary PCI within 120 minutes of symptom onset,the facilitated PCI with half-dose r-SAK significantly increased the proportion of STR≥70%at 60-90 minutes after PCI,reduced the formation of pathological Q waves,and shortened the time to peak hs-cTnT,without increasing the risk of bleeding,which should be an alternative reperfusion strategy worthy of further study.
5.18F-D3FSP PET/CT machine learning models for evaluating subjective cognitive decline
Fansheng MENG ; Zhanyu TIAN ; Wei GONG ; Liang XIONG ; Haizhuang JIANG ; Lijuan YU
Chinese Journal of Medical Imaging Technology 2025;41(4):573-577
Objective To observe the value of 18F-D3FSP PET/CT machine learning(ML)models for evaluating subjective cognitive decline(SCD).Methods Thirty-two SCD patients(SCD group)and 16 healthy volunteers(control group)who received 18F-D3FSP PET/CT were selected from Sino Longitudinal Study on Cognitive Decline(SILCODE)and divided into training set(n=34)and test set(n=14)at a ratio of 7∶3.Support vector machine(SVM),random forest(RF)and logistic regression(LR)models were constructed based on Hamilton anxiety scale(HAMA)and standard uptake value ratio(SUVR)of brain regions being significantly different between groups to evaluate SCD.Then PET/CT data were amplified by format conversion and divided into training set(including 8 775 CT images and 1 833 PET images)and test set(including 2 025 CT images and 423 PET images)at the ratio of 8∶2.VGG16 models were constructed based on CT and PET images to evaluate SCD,respectively.Results The area under the receiver operating characteristic curve(AUC)of SVM,RF and LR model for evaluating SCD in training set was all 1.000,while was 0.863,0.872 and 1.000 in test set,respectively.LR model was overfitting,and RF model had better performance.The accuracy of VGG16 model for evaluating SCD based on CT and PET images tended to be stable after the 175th and 150th iterations,with the highest accuracy of 67.11% and 65.35% in training set,which tended to be stable after the 165th and 145th iterations,with the highest accuracy of 62.43% and 59.16% in test set,respectively.Conclusion 18F-D3FSP PET/CT ML models could be used to evaluate SCD.
6.The changes and analysis of the ability of sound localization for patients with unilateral sudden hearing loss during the early period of treatment
Wenbin WANG ; Jiaqi SHANG ; Mingming WANG ; Shanshan TIAN ; Shuo LIANG ; Zhaomin FAN ; Haibo WANG ; Yu AI
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2025;60(7):769-775
Objective:To assess the sound localization ability of patients with unilateral sudden hearing loss during the early period of treatment, to explore its changing characteristics and to analyze influencing factors.Methods:A total of 22 patients with unilateral sudden sensorineural hearing loss, with onset within 3 days, who were hospitalized at Shandong Provincial ENT Hospital between January and April 2024, were collected in this study. The cohort included 13 males and 9 females, with a mean age of 36.5 years. Among them, 10 suffered in the right ear and 12 in the left ear. Additionally, 15 healthy individuals (8 males and 7 females, mean age 29.2 years) were selected as controls. Pure tone audiometry and sound localization tests were reviewed on the first day, third day, fifth day of admission; the third week after onset, and the pure tone average and the root-mean-square error(RMSE) were used as indicators, respectively. The improvement of the ability of sound localization and pure tone average were assessed by correlation analyses using SPSS, version 27.0, and multiple regression analysis was employed to explore effects that might influence sound localization ability.Results:The pure tone threshold and sound localization ability on the third week of onset were improved compared with those on the initial three instances(the first, third, and fifth days of admission). 9 of the 22 patients (40.91%, 9/22) presented normal sound localization ability whereas their hearing loss had not recurred yet. The Spearman correlation analysis revealed a significant positive correlation between the improvement of sound localization ability and hearing improvement ( r=0.57, P<0.001). Meanwhile, multiple regression analysis showed that hearing threshold was a significant factor for sound localization when there was audible frequency. Vice versa, at this circumstance, ages and vertigo were significant factors. Conclusions:For most of the patients with unilateral sudden hearing loss, ability of sound localization improves with the decrease of hearing threshold. Notably, some patients can restore normal levels of sound localization for white noise, even in the presence of hearing loss at certain frequencies, by relying on binaural acoustic cues provided by residual hearing.
7.Typical failure treatment of large-aperture 16-slice spiral Siemens SOMATOM Sensation Open CT
Yu-kun ZHU ; Shi-dong CHENG ; Ming YANG ; Fei WENG ; Jing TIAN ; Chen LIANG
Chinese Medical Equipment Journal 2025;46(11):112-114
Three typical failures of large-aperture 16-slice spiral Siemens SOMATOM Sensation Open CT were introduced in terms of phenomenon,cause and treatment method.References were provided for medical engineers to treat similar failures.
8.Typical failure treatment of large-aperture 16-slice spiral Siemens SOMATOM Sensation Open CT
Yu-kun ZHU ; Shi-dong CHENG ; Ming YANG ; Fei WENG ; Jing TIAN ; Chen LIANG
Chinese Medical Equipment Journal 2025;46(11):112-114
Three typical failures of large-aperture 16-slice spiral Siemens SOMATOM Sensation Open CT were introduced in terms of phenomenon,cause and treatment method.References were provided for medical engineers to treat similar failures.
9.Research on quality control method for magnetic resonance accelerator daily QA protocol based on self-developed phantom
Qiu GUAN ; Yuliang SUN ; Hao LIANG ; Wei TIAN ; Tingting DONG ; Lang YU ; Bo YANG ; Jie QIU
Chinese Journal of Radiation Oncology 2025;34(1):23-28
Objective:To establish daily quality assurance workflow based on self-developed phantom to ensure MR-linac performance such as beam accuracy, MR image guidance accuracy, and the clinical treatment workflow to enhance the efficiency of daily quality assurance (QA).Methods:The self-developed phantom was made by 3D printer and used in conjunction with Daily QA-MR detector array. After CT-sim scanning, a treatment plan was designed and transmitted to the accelerator, tests were performed such as image guidance accuracy, beam output and beam quality, the differences in daily QA results between the self-developed phantom and standard phantom recommended by the manufacturer were analyzed by using paired t-test. Results:A total of 24 sets results were collected, the image guide accuracy in the X, Y and Z directions between standard and self-made phantom were (0.1±0.4), (-0.14±0.16), (0.07±0.05) mm and (0±0.02), (-0.02±0.02), (0.02±0.01) mm, respectively, and the differences were statistically significant ( P<0.001, =0.001 and <0.001). Daily QA-MR detector array beam measurement results including output, symmetry, beam quality and field size were -0.11%±0.20%, -0.10%±0.19%, -0.01%±0.08%, (0.4±0.1) mm and (0.2±0.1) mm, respectively. The new process saved 25% (approximately 9 min) of the time compared to the standard process. Conclusions:The new daily QA process for MR-linac is performed based on self-developed phantom and Daily QA-MR detector array. The accuracy and sensitivity meet the requirements and can improve the QA efficiency.
10.Identification of high-risk areas for local tumor progression following microwave ablation of colorectal cancer liver metastases using three-dimensional MRI imaging
Lu LI ; Jianming LI ; Hefei LI ; Wenqi CHEN ; Jie HU ; Zhen WANG ; Xueqin TIAN ; Jie YU ; Ping LIANG
Chinese Journal of Ultrasonography 2025;34(5):431-438
Objective:To investigate the spatial distribution patterns of local tumor progression(LTP)after microwave ablation(MWA)for colorectal liver metastases(CRLMs)and identify high-risk progression zones.Methods:A total of 471 CRLM lesions from 246 patients treated with MWA at the Chinese PLA General Hospital between September 2009 and March 2022 were retrospectively analyzed. Three-dimensional visualized MRI image fusion technology was employed to evaluate the spatial relationship between ablation margins(AM)and LTP. The liver was partitioned into nine specific anatomical regions. Machine learning(Boruta algorithm)was used to assess the importance of these regions on LTP risk. Multivariate analysis of LTP was performed at the tumor level and at the patient level using the Cox mixed effects model and the Cox regression model,respectively.Results:LTP occurred in 115 lesions,with an LTP rate of 40.0%(80/200)in ablated lesions which were located in the high-risk progression area,and 12.9%(35/271)in low-risk progression area. Multivariate analysis identified AM < 5 mm,tumor size ≥3 cm and location in high-risk zones as independent risk factors for LTP. Notably,LTP in high-risk zones predominantly clustered around the ablation needle tip.Conclusions:Post-MWA LTP in CRLMs exhibits distinct spatial clustering,particularly at the needle tip within high-risk progression zones. These findings provide critical insights for optimizing ablation strategies and improving clinical outcomes.


Result Analysis
Print
Save
E-mail