1.RP-HPLC determination of valproate concentration in serum
Chinese Journal of Primary Medicine and Pharmacy 2006;0(08):-
Objective To establish an RP-HPLC method for determining serum level of valproate.Methods A symmetryshield RP18 column (5?m,3.9mm?150mm) was used.The mobile phase,methanol-water(80:20) was used at a flow rate of 1.0ml/min.The detector was Waters 2487 dual?absorbance detector,which was set at the wavelength of 248nm.Serum sample was extracted with 2ml acetic n-hexane,then valproic acid in organic layer was derived by adding into?-bromoacetophenone,and cyclohcxanecarboxyiic acid was selected as an internal stan- dard.Results The calibration curve was linear in the range of 5.0 to 250.0vtg/ml.The average recovery rate was 98.23%,and the RSD within-day and between-day were both less than 3 %.Conclusion This method is suitable for therapeutic drug monitoring of phenytoin.
2.Effect of transfected tissue inhibitor of metalloproteinase-2 on nuclear factor-?B and protein kinase C of the injured rabbit vascular smooth cells
Chinese Journal of Trauma 1993;0(05):-
Objective To study the expression changes of matrix metalloproteinases (MMPs), protein kinase C (PKC) and nuclear factor-?B (NF-?B ) on the injured rabbit vascular smooth muscular cells (VSMC) transfected with tissue inhibitor of metalloproteinase-2 (TIMP-2) vector. Methods Lipofectin method was used to transfect TIMP-2 vector into VSMC, Western blot analysis to detect TIMP-2 peptides and zymography assay to determine MMPs. The activities of MMPs and NF-?B were detected by electrophoretic mobility shift assay (EMSA). The mRNA and protein expressions of PKC? were determined by RT-PCR and immunocytochemistry. Results The injured VSMC showed increased enzyme activity of MMP-2. There was very lower level expressions of PKC? and NF-?B in the normal VSMC but high in the injured VSMC. However, in injured VSMC transfected with TIMP-2 vector, the activity of MMP2/9 was suppressed and the expressions of PKC? and NF-?B decreased (P
3.Qualitative research on psychological stress of the hospital workplace violence against the medical staff
Yongchen YU ; Fangliang ZOU ; Yifan CAI ; Limin LIN ; Zhuohua LIN ; Yanhong LU ; Wenzhi CAI
Chinese Journal of Practical Nursing 2014;30(10):6-9
Objective To investigate the stress reaction of the medical staff who suffered workplace violence,and provide reference for nursing interventions.Methods 13 medical staff who suffered work-place violence were interviewed through semi-constitutional formula,the data were analyzed by phenomenological method of qualitative research.Results The psychological stress of medical staff mainly included 3 themes:complex emotions,eager to help; psychological adjustment required internal and external integration; different stress reaction affected the psychological state.Conclusions The medical staff suffer seriously from the workplace violence both on the physical and mental health,individuals should learn how to deal with it correctly,and the relevant departments should pay full attention to the humane care to victims of violence,guide them to view the stress correctly,and to take effective measures to prevent and control workplace violence.
4.Electrical stimulation relieves ischemia of rat skeletal muscle via angiogenesis
Lin ZHONG ; Duan CAI ; Bo YU ; Yanling ZHANG ;
Chinese Journal of Physical Medicine and Rehabilitation 2003;0(03):-
Objective To investigate the effects of electrical stimulation on the expression of vascular endothelial growth factor(VEGF)mRNA and receptor FLK 1/KDR in a ischemic model of rat hindlimb. Methods The model of hindlimb ischemia on the right side was established by ligation of the superficial femoral artery in 10 rats. The rats were then randomized into an experimental group and a control group. The rats in the experimental group were intervened with electrical stimulation ( 25 Hz, 0.1 V) on the tibialis anterior (TA) of the right side, while those in the control group were not. RT PCR and immunohistological methods were used to detect the expressions of VEGF mRNA and protein in TA muscles. FLK 1/KDR was detected by means of Western blot and immunofluorescence. Results After 7 days of continuous stimulation, there was a significant increase in blood flow within the muscle. VEGF mRNA and VEGF protein had 4 fold and 2 fold increases, respectively, in the stimulated TA muscles as compared to the control(2.58 vs 0.93, 0.48 vs 0.24, P
5.Comparison between CT characteristics and histological differentiation of soft tissue sarcomas
Yangkang LI ; Jianbang LIN ; Yu ZHENG ; Aiqun CAI ; Xiuguo ZHOU
Journal of Practical Radiology 2014;(8):1351-1354
Objective To investigate the relationship between CT characteristics and histological differentiation of soft tissue sar-comas.Methods Forty-two cases with pathologically proved soft tissue sarcomas were collected.The tumor size,morphology,den-sity and relationship of the tumor to the adjacent structures on CT were analyzed retrospectively.The value of the CT signs in evalu-ating the histological differentiation of the tumor was explored.Results The maximal diameter of the tumor was over 5 cm in 36 ca-ses.Oval shape was seen in 29 cases and irregular shape was seen in 13 cases.Heterogeneous density was seen in 32 cases including intratumoral calcification in 3 cases and intratumoral necrosis in 22 cases.Adjacent structures were infiltrated in 25 cases.Compared to the pathological results,intratumoral necrosis and invasion of adjacent structures were related to the degree of histological differ-entiation (P <0.05),and the relation coefficients were 0.64 and 0.57,respectively (P <0.01).Conclusion Intratumoral necrosis and invasion of adjacent structures are correlated with the histological differentiation of the soft tissue sarcomas.They may reflect the biological behavior of low-differentiated or undifferentiated soft tissue sarcomas to some extent.
6.Research advances of recombinant coagulation factor VII expression and synthesizing mechanism
Lin PENG ; Xiao YU ; Yanfei CAI ; Jian JIN ; Huazhong LI
Journal of China Pharmaceutical University 2015;(5):623-628
Haemophilia is caused by lack of coagulation factor VIII or IX in patients′blood with inadequate hemostasis.Currently recombinant coagulation factor VII(rFVII)produced in different cells is used against clini-cal bleeding of haemophilia patients.To enhance the production and activity of rFVII;some eukaryotic cells such as baby hamster kidney(BHK);Chinese hamster ovary(CHO);insect cell and fish embryo;were used to express rFVII.Meanwhile;the effect of functional gene on the activity of rFVII and the limitation of rFVII production caused by post-translational modification were investigated by different methods.The role of rFVII in hemostasis;synthesis of rFVII in different eukaryotic cells and impact on production of post-translational modification are reviewed in this article.
7.Effect of monoclonal antibody to CD47 molecule on dendritic cell differentiation and function
Jing YU ; Maofang LIN ; Haibo MOU ; He HUANG ; Zhen CAI
Chinese Journal of Pathophysiology 2000;0(12):-
AIM: To explore the influence of CD47 molecules on the maturation and function of cultured dendritic cells (DCs). METHODS: Monocyte cell-derived DCs were propagated in granulocyte-macrophage colony-stimulating factor (GM-CSF) and lipopolysaccharide (LPS) plus interleukin (IL)-4, in the presence or absence of anti CD47 monoclonal antibodies (anti-CD47 mAbs). Flow cytometry was used to detect the cell surface phenotype. The concentration of IL-12P70 in supernatant was measured by ELISA technique. The antigen-presenting functions of DCs were determined in one-way mixed leukocyte reaction by Brdu-ELISA. Electrophoretic mobility shift assays (EMSA) was used to examine NF-?B activity. RESULTS: The anti-CD47 mAbs markedly suppressed the expression of CD80,CD86,CD83,CD1a,HLA-DR on the surface of DCs (P
8.The value of high frequency ultrasound in predicting spontaneous closure of patent ductus arteriosus in ;preterm neonates
Xia, YU ; Xianfang, LIN ; Zhicong, LIU ; Jie, CAI
Chinese Journal of Medical Ultrasound (Electronic Edition) 2014;(3):18-21
Objective To study the value of high frequency ultrasound in predicting spontaneous closure of patent duct arteriosus (PDA) in premature neonates. Methods One hundred and seventy premature neonates aged less than 37 weeks of gestation were enrolled. They were all admitted in the neonatal intensive care unit of Jinhua People′ s Hospital within 24 hours after birth. Echocardiographic examinations was conducted using GE′s Vivid I Portable color Doppler ultrasonography with routine cardiac probe (frequency 1.7-3.4 MHz) and high-frequency transducer (frequency 7.5 MHz). Up to the 7th day, the echocardiography was carried out every day after birth until the closure of PDA .They were divided to two groups according to whether spontaneous closure of PDA took place with in 7 days after birth (the control group) or not (the PDA group). There were 16 premature neonates in PDA group, including 6 male and 10 female. The mean gestational week at birth was (35.3±1.4) weeks. The mean birth weight was (2 330.9±325.5) g. Thirty-two premature neonates were included incontrol group, including 13 male and 19 female. The mean gestational week at birth was (35.0±1.3) weeks. The mean birth weight was (2 337.5±287.8) g. The clinical characteristics and echocardiographic parameters were compared between the two groups. Results The detection rates of high-frequency ultrasound and routine echocardiography were all 100%. The spontaneous closure rate of PDA in preterm infants at 24 hours, 48 hours, 72 hours were 18.8%(32/170), 61.2%(104/170), 78.8%(134/170) respectively. Within 7 days after birth, the closure rate was 90.6%(154/170), therefore the incidence of PDA in premature neonates was about 9.4%(16/170) in our study. The display rate of entire duct arteriosus using high frequency ultrasound was signiifcantly higher than that using routine ultrasound [82%(39/48) vs 46%(22/48), P<0.001, 100%(48/48) vs 77.1%(37/48), P<0.01]. The diameters of duct arteriosus in PDA group were signiifcantly larger than that in control group [(2.08±0.4) mm vs (1.09±0.22) mm, P<0.001]. However, the remaining echocardiographic parameters showed no signiifcant difference between the two groups (P>0.05). To predict the spontaneous closure of PDA in preterm neonates within 7 days after birth by high frequency ultrasound, the sensitivity, specificity and accuracy were 87.5%, 90.6% and 66.5% respectively using the cutoff point of 1.55 mm. While the sensitivity, speciifcity and accuracy were 75%, 93.7%, 44.15%by routine echocardiography with the cutoff point of 2.36 mm. Conclusions High-frequency ultrasound can conifrm the diagnosis of PDA in preterm infants and it is better than routine echocardiography in depicting the structure of arterial duct. The larger PDA diameter was suggestive of the lower possibility of spontaneous close.
9.Status quo and legitimacy analysis for temporarily dispensed drugs used in hospitals
Zhibo CAI ; Yan LIN ; Yu WANG ; Bingyi SHENG
Chinese Journal of Hospital Administration 2009;25(4):266-269
Availability of appropriate drugs for children has been a bottleneck both at home and abroad for years.As a result, drugs for adults that are market available emerge a choice of convenience for children's treatment instead.For unique physiological and psychological characteristics of children, these drugs must be dispensed on individual basis before usage to children in question.Such drugs play a key role in children's treatment, and incur many problems on the other hand in their use and practice, such as drug stability, dosage accuracy, potential risks, as well as legitimacy in drug dispensing and use.A safe, reasonable and normalized use of such drugs calls for an orchestrated effort among pharmacists, trade associations and drug regulators as well.
10.Expression of CD4+, CD25+ regulatory T cells and its significance in carcinoma of stomach
Lin TIAN ; Minna LIU ; Lihua HU ; Xueying CHEN ; Yu CAI
Journal of Chinese Physician 2009;11(4):439-440
Objective To study the expression of CD4+, CD25+ regulatory T cells and its significance in carcinoma of stomach. Methods Flow cytometry was used to quantify and analyze the results of CD4+, CD25 + regulatory T cells and CD8+ T cells in 76 patients with gastric cancer. Results CD4+, CD25+ regulatory T cells expression in gastric cancer tissue, adjacent tissues and control group are (1.2±0.9) %, (6.4±1.1) % and (4.1±0.8) %. The results have statistical significance (P<0.05). CD8+ T cells markedly de-creased in gastric cancer tissue, while CD4+ , CD25+ regulatory T cells increased. But this manifest did not happen in adjacent tissues.Conclusion CD4+, CD25+ regulatory T cells suppress gastric cancer though inhibiting CD8+ T cells.